메뉴 건너뛰기




Volumn 14, Issue 2, 2010, Pages 131-138

Cardiac output measured by the FloTrac/Vigileo system: Does the "plug and play"principle work?

Author keywords

Cardiac output; Pulmonary artery catheter; Pulse contor analysis; Semi invasive; Thermodilution

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; CLINICAL ARTICLE; COMPUTER PROGRAM; CONTROLLED STUDY; ERRORS, ARTIFACTS AND QUALITY CONTROL PROCEDURES; EXTRACORPOREAL CIRCULATION; FEMALE; FLOW MEASUREMENT; HEART HEMODYNAMICS; HEART OUTPUT; HEART SURGERY; HUMAN; MALE; PRIORITY JOURNAL; THERMODILUTION;

EID: 77954579184     PISSN: 09205268     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (18)
  • 2
    • 23444461703 scopus 로고    scopus 로고
    • PAC-Man study collaboration. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (pac-man): A randomised controlled trial
    • Harvey S, Harrison DA, Singer M, Ashcroft J, Jones CM, Elbourne D, Brampton W, Williams D, Young D, Rowan K, PAC-Man study collaboration. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (pac-man): A randomised controlled trial. Lancet 2005; 366: 472-77
    • (2005) Lancet , vol.366 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3    Ashcroft, J.4    Jones, C.M.5    Elbourne, D.6    Brampton, W.7    Williams, D.8    Young, D.9    Rowan, K.10
  • 4
    • 27944473556 scopus 로고    scopus 로고
    • Messung des Herzzeitvolumens
    • quiz 1152-3
    • Reuter DA, Goetz AE. Messung des Herzzeitvolumens. Anaesthesist 2005; 54: 1135-51; quiz 1152-3
    • (2005) Anaesthesist , vol.54 , pp. 1135-1151
    • Reuter, D.A.1    Goetz, A.E.2
  • 5
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • table of contents
    • Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, Sztark F. Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008; 106: 1480-6, table of contents
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Vallet, A.4    Cochard, J.F.5    Revel, P.6    Sztark, F.7
  • 6
    • 33847753396 scopus 로고    scopus 로고
    • Semi-Invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • Mayer J, Boldt J, Schöllhorn T, Röhm KD, Mengistu AM, Suttner S. Semi-Invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007; 98: 176-182
    • (2007) Br J Anaesth , vol.98 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schöllhorn, T.3    Röhm, K.D.4    Mengistu, A.M.5    Suttner, S.6
  • 7
    • 39749138803 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device
    • table of contents
    • Mayer J, Boldt J, Wolf MW, Lang J, Suttner S. Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device. Anesth Analg 2008; 106: 867-72, table of contents
    • (2008) Anesth Analg , vol.106 , pp. 867-872
    • Mayer, J.1    Boldt, J.2    Wolf, M.W.3    Lang, J.4    Suttner, S.5
  • 9
    • 36448936056 scopus 로고    scopus 로고
    • Evaluation of an improved algorithm for arterial pressure-based cardiac output assessment without external calibration
    • Prasser C, Trabold B, Schwab A, Keyl C, Ziegler S, Wiesenack C. Evaluation of an improved algorithm for arterial pressure-based cardiac output assessment without external calibration. Intensive Care Med 2007; 33: 2223-25
    • (2007) Intensive Care Med , vol.33 , pp. 2223-2225
    • Prasser, C.1    Trabold, B.2    Schwab, A.3    Keyl, C.4    Ziegler, S.5    Wiesenack, C.6
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15: 85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 12
    • 38549151697 scopus 로고    scopus 로고
    • Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
    • Hamzaoui O, Monnet X, Richard C, Osman D, Chemla D, Teboul JL. Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008; 36: 434-440
    • (2008) Crit Care Med , vol.36 , pp. 434-440
    • Hamzaoui, O.1    Monnet, X.2    Richard, C.3    Osman, D.4    Chemla, D.5    Teboul, J.L.6
  • 13
    • 33846894301 scopus 로고    scopus 로고
    • A pilot assessment of the flotrac cardiac output monitoring system
    • Opdam HI, Wan L, Bellomo R. A pilot assessment of the flotrac cardiac output monitoring system. Intensive Care Med 2007; 33: 344-49
    • (2007) Intensive Care Med , vol.33 , pp. 344-349
    • Opdam, H.I.1    Wan, L.2    Bellomo, R.3
  • 14
    • 77953762414 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform analysis without calibration vs. Thermodilution in septic shock: Evolving accuracy of software versions
    • Slagt C, Beute J, Hoeksema M, Malagon I, Mulder JW, Groeneveld JA. Cardiac output derived from arterial pressure waveform analysis without calibration vs. Thermodilution in septic shock: Evolving accuracy of software versions. Eur J Anaesthesiol 2010
    • (2010) Eur J Anaesthesiol
    • Slagt, C.1    Beute, J.2    Hoeksema, M.3    Malagon, I.4    Mulder, J.W.5    Groeneveld, J.A.6
  • 15
    • 77951628544 scopus 로고    scopus 로고
    • Variations in arterial blood pressure are associated with parallel changes in flowtrac/vigileo-derived cardiac output measurements: A prospective comparison study
    • Eleftheriadis S, Galatoudis Z, Didilis V, Bougioukas I, Schön J, Heinze H, Berger KU, Heringlake M. Variations in arterial blood pressure are associated with parallel changes in flowtrac/vigileo-derived cardiac output measurements: A prospective comparison study. Crit Care 2009; 13: R179
    • (2009) Crit Care , vol.13
    • Eleftheriadis, S.1    Galatoudis, Z.2    Didilis, V.3    Bougioukas, I.4    Schön, J.5    Heinze, H.6    Berger, K.U.7    Heringlake, M.8
  • 16
    • 71249127973 scopus 로고    scopus 로고
    • Comparison of stroke volume variations derived from radial and femoral arterial pressure waveforms during liver transplantation
    • Kim YK, Shin WJ, Song JG, Jun IG, Kim HY, Seong SH, Hwang GS. Comparison of stroke volume variations derived from radial and femoral arterial pressure waveforms during liver transplantation. Transplant Proc 2009; 41: 4220-28
    • (2009) Transplant Proc , vol.41 , pp. 4220-4228
    • Kim, Y.K.1    Shin, W.J.2    Song, J.G.3    Jun, I.G.4    Kim, H.Y.5    Seong, S.H.6    Hwang, G.S.7
  • 17
    • 0030843904 scopus 로고    scopus 로고
    • Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial
    • Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial. BMJ 1997; 315: 909-912
    • (1997) BMJ , vol.315 , pp. 909-912
    • Sinclair, S.1    James, S.2    Singer, M.3
  • 18
    • 27744442396 scopus 로고    scopus 로고
    • Intraoperative oesophageal doppler guided fluid management shortens postoperative hospital stay after major bowel surgery
    • Wakeling HG, McFall MR, Jenkins CS, Woods WG, Miles WF, Barclay GR, Fleming SC. Intraoperative oesophageal doppler guided fluid management shortens postoperative hospital stay after major bowel surgery. Br J Anaesth 2005; 95: 634-642
    • (2005) Br J Anaesth , vol.95 , pp. 634-642
    • Wakeling, H.G.1    McFall, M.R.2    Jenkins, C.S.3    Woods, W.G.4    Miles, W.F.5    Barclay, G.R.6    Fleming, S.C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.