Volumn 34, Issue 7, 2010, Pages 537-545

A novel subcutaneous counterpulsation device: Acute hemodynamic efficacy during pharmacologically induced hypertension, hypotension, and heart failure

Author keywords

Cardiac surgery; Counterpulsation; Counterpulsation device; Heart failure; Intra aortic balloon pump

Indexed keywords

BALLOONS; CARDIOLOGY; CARDIOVASCULAR SURGERY; HEART; HEMODYNAMICS;

EID: 77954350611     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01009.x     Document Type: Article
Times cited : (25)

References (30)
  • 1
    • 1242271337 scopus 로고    scopus 로고
    • Short- and long-term mechanical ventricular assistance towards myocardial recovery
    • Entwistle JW 3rd. Short- and long-term mechanical ventricular assistance towards myocardial recovery. Surg Clin North Am 2004 84 : 201 221.
    • (2004) Surg Clin North Am , vol.84 , pp. 201-221
    • Entwistle III, J.W.1
  • 2
    • 0032547931 scopus 로고    scopus 로고
    • Implantable left ventricular assist devices
    • Goldstein DJ, Oz MC, Rose EA. Implantable left ventricular assist devices. N Engl J Med 1998 339 : 1522 1533.
    • (1998) N Engl J Med , vol.339 , pp. 1522-1533
    • Goldstein, D.J.1    Oz, M.C.2    Rose, E.A.3
  • 3
    • 0035892018 scopus 로고    scopus 로고
    • Long-term mechanical left ventricular assistance for end-stage heart failure
    • Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med 2001 345 : 1435 1443.
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 4
    • 1642409474 scopus 로고    scopus 로고
    • The role of bridge to transplantation: Should LVAD patients be transplanted?
    • Birks EJ, Yacoub MH, Banner NR, Khaghani A. The role of bridge to transplantation: should LVAD patients be transplanted? Curr Opin Cardiol 2004 19 : 148 153.
    • (2004) Curr Opin Cardiol , vol.19 , pp. 148-153
    • Birks, E.J.1    Yacoub, M.H.2    Banner, N.R.3    Khaghani, A.4
  • 5
    • 23044498227 scopus 로고    scopus 로고
    • Multicenter experience: Prevention and management of left ventricular assist device infections
    • DOI 10.1097/01.mat.0000170620.65279.aa
    • Chinn R, Dembitsky W, Eaton L, et al. Multicenter experience: prevention and management of left ventricular assist device infections. ASAIO J 2005 51 : 461 470. (Pubitemid 41076784)
    • (2005) ASAIO Journal , vol.51 , Issue.4 , pp. 461-470
    • Chinn, R.1    Dembitsky, W.2    Eaton, L.3    Chillcott, S.4    Stahovich, M.5    Rasmusson, B.6    Pagani, F.7
  • 6
    • 33646061032 scopus 로고    scopus 로고
    • Intra-aortic balloon counterpulsation
    • Trost JC, Hillis LD. Intra-aortic balloon counterpulsation. Am J Cardiol 2006 97 : 1391 1398.
    • (2006) Am J Cardiol , vol.97 , pp. 1391-1398
    • Trost, J.C.1    Hillis, L.D.2
  • 8
    • 0036164120 scopus 로고    scopus 로고
    • Skeletal muscle ventricle aortic counterpulsation: Function during chronic heart failure
    • Patel BG, Shah SH, Astra LI, et al. Skeletal muscle ventricle aortic counterpulsation: function during chronic heart failure. Ann Thorac Surg 2002 73 : 588 593.
    • (2002) Ann Thorac Surg , vol.73 , pp. 588-593
    • Patel, B.G.1    Shah, S.H.2    Astra, L.I.3
  • 9
    • 0023787284 scopus 로고
    • Hemodynamic effects of a counterpulsation device implanted on the ascending aorta in severe cardiogenic shock
    • Nanas JN, Nanas SN, Charitos CE, et al. Hemodynamic effects of a counterpulsation device implanted on the ascending aorta in severe cardiogenic shock. ASAIO Trans 1988 34 : 229 234.
    • (1988) ASAIO Trans , vol.34 , pp. 229-234
    • Nanas, J.N.1    Nanas, S.N.2    Charitos, C.E.3
  • 10
    • 0026192647 scopus 로고
    • Comparison of an extraaortic counterpulsation device versus intraaortic balloon pumping in severe cardiac failure
    • Zelano JA, Ko W, Lazzaro R, et al. Comparison of an extraaortic counterpulsation device versus intraaortic balloon pumping in severe cardiac failure. ASAIO Trans 1991 37 : M342 4.
    • (1991) ASAIO Trans , vol.37
    • Zelano, J.A.1    Ko, W.2    Lazzaro, R.3
  • 11
    • 0346750830 scopus 로고    scopus 로고
    • Superior performance of a paraaortic counterpulsation device compared to the intraaortic balloon pump
    • Terrovitis JV, Charitos CE, Tsolakis EJ, et al. Superior performance of a paraaortic counterpulsation device compared to the intraaortic balloon pump. World J Surg 2003 27 : 1311 1316.
    • (2003) World J Surg , vol.27 , pp. 1311-1316
    • Terrovitis, J.V.1    Charitos, C.E.2    Tsolakis, E.J.3
  • 12
    • 0037167648 scopus 로고    scopus 로고
    • Circulatory assistance with a permanent implantable IABP: Initial human experience
    • Jeevanandam V, Jayakar D, Anderson AS, et al. Circulatory assistance with a permanent implantable IABP: initial human experience. Circulation 2002 106 : I183 8.
    • (2002) Circulation , vol.106
    • Jeevanandam, V.1    Jayakar, D.2    Anderson, A.S.3
  • 13
    • 24644517013 scopus 로고    scopus 로고
    • Extra-aortic balloon counterpulsation: An intraoperative feasibility study
    • Legget ME, Peters WS, Milsom FP, et al. Extra-aortic balloon counterpulsation: an intraoperative feasibility study. Circulation 2005 112 : I26 31.
    • (2005) Circulation , vol.112 , pp. 26-31
    • Legget, M.E.1    Peters, W.S.2    Milsom, F.P.3
  • 14
    • 33845803269 scopus 로고    scopus 로고
    • Hemodynamic effects of partial ventricular support in chronic heart failure: Results of simulation validated with in vivo data
    • Morley D, Litwak K, Ferber P, et al. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data. J Thorac Cardiovasc Surg 2007 133 : 21 8.
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 21-28
    • Morley, D.1    Litwak, K.2    Ferber, P.3
  • 15
    • 33645742490 scopus 로고    scopus 로고
    • Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach
    • Giridharan GA, Pantalos GM, Litwak KN, Spence PA, Koenig SC. Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach. ASAIO J 2006 52 : 39 46.
    • (2006) ASAIO J , vol.52 , pp. 39-46
    • Giridharan, G.A.1    Pantalos, G.M.2    Litwak, K.N.3    Spence, P.A.4    Koenig, S.C.5
  • 16
    • 11144267937 scopus 로고    scopus 로고
    • Hemodynamic and left ventricular pressure-volume responses to counterpulsation in mock circulation and acute large animal models
    • Koenig SC, Pantalos GM, Litwak KN, et al. Hemodynamic and left ventricular pressure-volume responses to counterpulsation in mock circulation and acute large animal models. Conf Proc IEEE Eng Med Biol Soc 2004 5 : 3761 3764.
    • (2004) Conf Proc IEEE Eng Med Biol Soc , vol.5 , pp. 3761-3764
    • Koenig, S.C.1    Pantalos, G.M.2    Litwak, K.N.3
  • 17
    • 33746850153 scopus 로고    scopus 로고
    • Development and early testing of a simple subcutaneous counterpulsation device
    • Koenig SC, Spence PA, Pantalos GM, Dowling RD, Litwak KN. Development and early testing of a simple subcutaneous counterpulsation device. ASAIO J 2006 52 : 362 367.
    • (2006) ASAIO J , vol.52 , pp. 362-367
    • Koenig, S.C.1    Spence, P.A.2    Pantalos, G.M.3    Dowling, R.D.4    Litwak, K.N.5
  • 18
    • 59649096606 scopus 로고    scopus 로고
    • Acute hemodynamic efficacy of a 32-mL subcutaneous counterpulsation device in a calf model of diminished cardiac function
    • Koenig SC, Litwak KN, Giridharan GA, et al. Acute hemodynamic efficacy of a 32-mL subcutaneous counterpulsation device in a calf model of diminished cardiac function. ASAIO J 2008 54 : 578 584.
    • (2008) ASAIO J , vol.54 , pp. 578-584
    • Koenig, S.C.1    Litwak, K.N.2    Giridharan, G.A.3
  • 19
    • 0026542535 scopus 로고
    • Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model
    • Smalling RW, Cassidy DB, Barrett R, Lachterman B, Felli P, Amirian J. Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model. Circulation 1992 85 : 1152 1159.
    • (1992) Circulation , vol.85 , pp. 1152-1159
    • Smalling, R.W.1    Cassidy, D.B.2    Barrett, R.3    Lachterman, B.4    Felli, P.5    Amirian, J.6
  • 20
    • 0021808418 scopus 로고
    • Adjunctive left ventricular unloading during myocardial reperfusion plays a major role in minimizing myocardial infarct size
    • Laschinger JC, Grossi EA, Cunningham JN Jr., et al. Adjunctive left ventricular unloading during myocardial reperfusion plays a major role in minimizing myocardial infarct size. J Thorac Cardiovasc Surg 1985 90 : 80 5.
    • (1985) J Thorac Cardiovasc Surg , vol.90 , pp. 80-85
    • Laschinger, J.C.1    Grossi, E.A.2    Cunningham, Jr.J.N.3
  • 21
    • 2442704269 scopus 로고    scopus 로고
    • Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices
    • Koenig SC, Woolard C, Drew G, et al. Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices. Biomed Instrum Technol 2004 38 : 229 240.
    • (2004) Biomed Instrum Technol , vol.38 , pp. 229-240
    • Koenig, S.C.1    Woolard, C.2    Drew, G.3
  • 22
    • 2442599564 scopus 로고    scopus 로고
    • HEART: An automated beat-to-beat cardiovascular analysis package using Matlab
    • Schroeder MJ, Perreault B, Ewert DL, Koenig SC. HEART: an automated beat-to-beat cardiovascular analysis package using Matlab. Comput Biol Med 2004 34 : 371 388.
    • (2004) Comput Biol Med , vol.34 , pp. 371-388
    • Schroeder, M.J.1    Perreault, B.2    Ewert, D.L.3    Koenig, S.C.4
  • 23
    • 22544452160 scopus 로고    scopus 로고
    • Mechanical device-based methods of managing and treating heart failure
    • Mancini D, Burkhoff D. Mechanical device-based methods of managing and treating heart failure. Circulation 2005 112 : 438 448.
    • (2005) Circulation , vol.112 , pp. 438-448
    • Mancini, D.1    Burkhoff, D.2
  • 24
    • 33750500333 scopus 로고    scopus 로고
    • Left ventricular assist device and drug therapy for the reversal of heart failure
    • Birks EJ, Tansley PD, Hardy J, et al. Left ventricular assist device and drug therapy for the reversal of heart failure. N Engl J Med 2006 355 : 1873 1884.
    • (2006) N Engl J Med , vol.355 , pp. 1873-1884
    • Birks, E.J.1    Tansley, P.D.2    Hardy, J.3
  • 25
    • 34247620544 scopus 로고    scopus 로고
    • Molecular signature of recovery following combination left ventricular assist device (LVAD) support and pharmacologic therapy
    • Hall JL, Birks EJ, Grindle S, et al. Molecular signature of recovery following combination left ventricular assist device (LVAD) support and pharmacologic therapy. Eur Heart J 2007 28 : 613 627.
    • (2007) Eur Heart J , vol.28 , pp. 613-627
    • Hall, J.L.1    Birks, E.J.2    Grindle, S.3
  • 26
    • 33747163976 scopus 로고    scopus 로고
    • Myocardial expression of the arginine:Glycine amidinotransferase gene is elevated in heart failure and normalized after recovery: Potential implications for local creatine synthesis
    • Cullen ME, Yuen AH, Felkin LE, et al. Myocardial expression of the arginine:glycine amidinotransferase gene is elevated in heart failure and normalized after recovery: potential implications for local creatine synthesis. Circulation 2006 114 : I16 20.
    • (2006) Circulation , vol.114 , pp. 16-20
    • Cullen, M.E.1    Yuen, A.H.2    Felkin, L.E.3
  • 27
    • 0023815639 scopus 로고
    • Cardiac disuse atrophy during LVAD pumping
    • Kinoshita M, Takano H, Taenaka Y, et al. Cardiac disuse atrophy during LVAD pumping. ASAIO Trans 1988 34 : 208 212.
    • (1988) ASAIO Trans , vol.34 , pp. 208-212
    • Kinoshita, M.1    Takano, H.2    Taenaka, Y.3
  • 28
    • 0030022732 scopus 로고    scopus 로고
    • Influence of prolonged ventricular assistance on myocardial histopathology in intact heart
    • Kinoshita M, Takano H, Takaichi S, Taenaka Y, Nakatani T. Influence of prolonged ventricular assistance on myocardial histopathology in intact heart. Ann Thorac Surg 1996 61 : 640 645.
    • (1996) Ann Thorac Surg , vol.61 , pp. 640-645
    • Kinoshita, M.1    Takano, H.2    Takaichi, S.3    Taenaka, Y.4    Nakatani, T.5
  • 29
    • 0027792029 scopus 로고
    • The limits of counterpulsation
    • Moulopoulos SD. The limits of counterpulsation. Int J Artif Organs 1993 16 : 803 805.
    • (1993) Int J Artif Organs , vol.16 , pp. 803-805
    • Moulopoulos, S.D.1
  • 30
    • 57049090050 scopus 로고    scopus 로고
    • Human, bovine and porcine systematic vascular input impedances are not equivalent: Implications for device testing and xenotransplantation in heart failure
    • Koenig SC, Giridharan GA, Ewart DL, et al. Human, bovine and porcine systematic vascular input impedances are not equivalent: implications for device testing and xenotransplantation in heart failure. J Heart Lung Transplant 2008 27 : 1340 1347.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1340-1347
    • Koenig, S.C.1    Giridharan, G.A.2    Ewart, D.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.