메뉴 건너뛰기




Volumn 52, Issue 1, 2006, Pages 39-46

Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING; BIOMEDICAL EQUIPMENT; COMPUTER SIMULATION; HEMODYNAMICS; PHYSIOLOGY; SURGERY;

EID: 33645742490     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mat.0000196522.29376.96     Document Type: Article
Times cited : (26)

References (19)
  • 1
    • 0028222727 scopus 로고
    • Counterpulsation: Historical background, technical improvements, hemodynamic and metabolic effects
    • Nanas JN, Moulopoulos SD: Counterpulsation: Historical background, technical improvements, hemodynamic and metabolic effects. Cardiology 84:156-167, 1994.
    • (1994) Cardiology , vol.84 , pp. 156-167
    • Nanas, J.N.1    Moulopoulos, S.D.2
  • 2
    • 18744376046 scopus 로고    scopus 로고
    • Basic principles of the intraaortic balloon pump and mechanisms affecting its performance
    • Papaioannou GT, Stefanadis C: Basic principles of the intraaortic balloon pump and mechanisms affecting its performance. ASAIO J 51:296-300, 2005.
    • (2005) ASAIO J , vol.51 , pp. 296-300
    • Papaioannou, G.T.1    Stefanadis, C.2
  • 3
    • 0030943326 scopus 로고    scopus 로고
    • Intraaortic balloon pumping for cardiac support: Trends in practice and outcome, 1968 to 1995
    • Torchiana DF, Hirsch G, Buckley MJ, et al: Intraaortic balloon pumping for cardiac support: trends in practice and outcome, 1968 to 1995. J Thor Cardiovasc Surg 113: 758-764, 1997.
    • (1997) J Thor Cardiovasc Surg , vol.113 , pp. 758-764
    • Torchiana, D.F.1    Hirsch, G.2    Buckley, M.J.3
  • 4
    • 0024156349 scopus 로고
    • Intraaortic balloon pumping for prolonged circulatory support
    • Freed PS, Wasfie T, Zado B, Kantrowitz A: Intraaortic balloon pumping for prolonged circulatory support. Am J Cardiol 61: 554-557, 1988.
    • (1988) Am J Cardiol , vol.61 , pp. 554-557
    • Freed, P.S.1    Wasfie, T.2    Zado, B.3    Kantrowitz, A.4
  • 5
    • 0030932030 scopus 로고    scopus 로고
    • Implications for the vascular surgeon with prolonged (3 to 89 days) intraaortic balloon pump counterpulsation
    • Manord JD, Garrard CL, Mehra MR, et al: Implications for the vascular surgeon with prolonged (3 to 89 days) intraaortic balloon pump counterpulsation. J Vasc Surg 26: 511-516, 1997.
    • (1997) J Vasc Surg , vol.26 , pp. 511-516
    • Manord, J.D.1    Garrard, C.L.2    Mehra, M.R.3
  • 6
    • 0037167648 scopus 로고    scopus 로고
    • Circulatory assistance with a permanent implantable IABP: Initial human experience
    • Jeevanandam V, Jayakar D, Anderson AS, et al: Circulatory assistance with a permanent implantable IABP: Initial human experience. Circulation 24: I183-I188, 2002.
    • (2002) Circulation , vol.24
    • Jeevanandam, V.1    Jayakar, D.2    Anderson, A.S.3
  • 7
    • 0017233807 scopus 로고
    • Permanent in-series cardiac assistance with the dynamic aortic patch: Blood-prosthesis interaction in long-term canine experiments
    • Schraut W, Kiso I, Freed P, et al: Permanent in-series cardiac assistance with the dynamic aortic patch: Blood-prosthesis interaction in long-term canine experiments. Surgery 79: 193-201, 1976.
    • (1976) Surgery , vol.79 , pp. 193-201
    • Schraut, W.1    Kiso, I.2    Freed, P.3
  • 8
    • 0030022664 scopus 로고    scopus 로고
    • A valveless high stroke volume counterpulsation device restores hemodynamics in patients with congestive heart failure and intractable cardiogenic shock awaiting heart transplantation
    • Nanas JN, Lolas CT, Charitos CE, et al: A valveless high stroke volume counterpulsation device restores hemodynamics in patients with congestive heart failure and intractable cardiogenic shock awaiting heart transplantation. J Thorac Cardiovasc Surg 111: 55-61, 1996.
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 55-61
    • Nanas, J.N.1    Lolas, C.T.2    Charitos, C.E.3
  • 9
    • 4544295738 scopus 로고    scopus 로고
    • Left ventricular and myocardial perfusion responses to volume unloading and afterload reduction in a computer simulation
    • Giridharan GA, Ewert DL, Pantalos GM et al: Left ventricular and myocardial perfusion responses to volume unloading and afterload reduction in a computer simulation. ASAIO J 50: 512-518, 2004.
    • (2004) ASAIO J , vol.50 , pp. 512-518
    • Giridharan, G.A.1    Ewert, D.L.2    Pantalos, G.M.3
  • 10
    • 0036558955 scopus 로고    scopus 로고
    • Modeling and control of a brushless DC axial flow ventricular assist device
    • Giridharan GA, Skliar M, Olsen DB, Pantalos GM: Modeling and control of a brushless DC axial flow ventricular assist device. ASAIO J 48: 272-289, 2002.
    • (2002) ASAIO J , vol.48 , pp. 272-289
    • Giridharan, G.A.1    Skliar, M.2    Olsen, D.B.3    Pantalos, G.M.4
  • 11
    • 0037898308 scopus 로고    scopus 로고
    • Control strategy for maintaining physiological perfusion with implantable rotary blood pumps
    • Giridharan GA, Skliar M: Control strategy for maintaining physiological perfusion with implantable rotary blood pumps. Artif Organs 27: 639-48, 2003.
    • (2003) Artif Organs , vol.27 , pp. 639-648
    • Giridharan, G.A.1    Skliar, M.2
  • 12
    • 0036428619 scopus 로고    scopus 로고
    • Nonlinear controller for ventricular assist devices
    • Giridharan GA, Skliar M: Nonlinear controller for ventricular assist devices. Artif Organs 26:980-984, 2002.
    • (2002) Artif Organs , vol.26 , pp. 980-984
    • Giridharan, G.A.1    Skliar, M.2
  • 13
    • 0034841434 scopus 로고    scopus 로고
    • Modeling of the human circulatory system with an axial flow ventricular assist device
    • Giridharan GA, Skliar M: Modeling of the human circulatory system with an axial flow ventricular assist device. In: Proceedings of the American Control Conference 5, 2001, pp. 3801-3806.
    • (2001) Proceedings of the American Control Conference 5 , pp. 3801-3806
    • Giridharan, G.A.1    Skliar, M.2
  • 14
    • 0348230939 scopus 로고    scopus 로고
    • Characterization of an adult mock circulation for testing cardiac support devices
    • Pantalos GM, Gillars KJ, Ewert DL, et al: Characterization of an adult mock circulation for testing cardiac support devices. ASAIO J 50: 37-46, 2004.
    • (2004) ASAIO J , vol.50 , pp. 37-46
    • Pantalos, G.M.1    Gillars, K.J.2    Ewert, D.L.3
  • 15
    • 0019799237 scopus 로고
    • Design and evaluation of the Pennsylvania State University mock circulatory system
    • Rosenberg G, Phillips WG, Landis DL, Pierce WS: Design and evaluation of the Pennsylvania State University mock circulatory system. ASAIO J 4: 41-49, 1981.
    • (1981) ASAIO J , vol.4 , pp. 41-49
    • Rosenberg, G.1    Phillips, W.G.2    Landis, D.L.3    Pierce, W.S.4
  • 16
    • 0012183405 scopus 로고    scopus 로고
    • Left ventricular simulator for cardiovascular device testing
    • Pantalos GM, Hayes J, Khanwilkar P, et al: Left ventricular simulator for cardiovascular device testing. ASAIO J 42: 46., 1996.
    • (1996) ASAIO J , vol.42 , pp. 46
    • Pantalos, G.M.1    Hayes, J.2    Khanwilkar, P.3
  • 17
    • 2442704269 scopus 로고    scopus 로고
    • Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices
    • Koenig SC, Woolard C, Drew G, et al: Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices. Biomed Instrum Technol 38: 229-240, 2004.
    • (2004) Biomed Instrum Technol , vol.38 , pp. 229-240
    • Koenig, S.C.1    Woolard, C.2    Drew, G.3
  • 19
    • 2442599564 scopus 로고    scopus 로고
    • HEART: An automated beat-to-beat cardiovascular analysis package using Matlab™
    • Schroeder MJ, Perrrault B, Ewert DL, Koenig SC: HEART: An automated beat-to-beat cardiovascular analysis package using Matlab™. Comput Biol Med 34:371-388, 2004.
    • (2004) Comput Biol Med , vol.34 , pp. 371-388
    • Schroeder, M.J.1    Perrrault, B.2    Ewert, D.L.3    Koenig, S.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.