Monte Carlo dose calculations in the treatment of a pelvis with implant and comparison with pencil-beam calculations

Author keywords

Dose calculation; Monte Carlo; Prosthetic hip

Indexed keywords

ALGORITHM; ANALYTICAL ERROR; ARTICLE; CANCER CONTROL; CANCER RADIOTHERAPY; DOSE CALCULATION; DOSIMETRY; HIP PROSTHESIS; IMPLANT; INTERMETHOD COMPARISON; LIGHT ABSORPTION; MONTE CARLO METHOD; PELVIS; PELVIS CANCER; PRIORITY JOURNAL; PROBABILITY; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; TREATMENT PLANNING;

EID: 0346218242     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.meddos.2003.05.001     Document Type: Article
Times cited : (20)

References (17)
  • 4
    • 0002290795 scopus 로고
    • Dose calculations for radiation treatment planning
    • T.M. et al. Jenkins. New York: Plenum
    • Mohan R. Dose calculations for radiation treatment planning. Jenkins T.M., et al. Monte Carlo Transport of Electrons and Photons. 1988;549-573 Plenum, New York.
    • (1988) Monte Carlo Transport of Electrons and Photons , pp. 549-573
    • Mohan, R.1
  • 5
    • 0027157683 scopus 로고
    • Decomposition of pencil beam kernels for fast dose calculations in three-dimensional treatment planning
    • Bortfeld T., Schlegel W., Rhein B. Decomposition of pencil beam kernels for fast dose calculations in three-dimensional treatment planning. Med. Phys. 20:1993;311-318.
    • (1993) Med. Phys. , vol.20 , pp. 311-318
    • Bortfeld, T.1    Schlegel, W.2    Rhein, B.3
  • 8
    • 0026750950 scopus 로고
    • A pencil beam model for photon dose calculation
    • Ahnesjö A., Saxner M., Trepp A. A pencil beam model for photon dose calculation. Med Phys. 19:1992;263-273.
    • (1992) Med Phys , vol.19 , pp. 263-273
    • Ahnesjö, A.1    Saxner, M.2    Trepp, A.3
  • 10
    • 0004843368 scopus 로고    scopus 로고
    • Verification of Monte-Carlo photon dose calculations and comparison with pencil-beam algorithms in the presence of tissue inhomogeneities
    • Laub W.U., Alber M., Nüsslin F. Verification of Monte-Carlo photon dose calculations and comparison with pencil-beam algorithms in the presence of tissue inhomogeneities. Radiother. Oncol. 48:(Suppl 1):1998;123.
    • (1998) Radiother. Oncol , vol.48 , Issue.SUPPL. 1 , pp. 123
    • Laub, W.U.1    Alber, M.2    Nüsslin, F.3
  • 11
    • 0031858002 scopus 로고    scopus 로고
    • A patient-specific Monte-Carlo dose-calculation method for photon beams
    • Lu W., Chen-Shou C., Lovelock M. A patient-specific Monte-Carlo dose-calculation method for photon beams. Med. Phys. 25:1998;867-878.
    • (1998) Med. Phys. , vol.25 , pp. 867-878
    • Lu, W.1    Chen-Shou, C.2    Lovelock, M.3
  • 12
    • 0031950887 scopus 로고    scopus 로고
    • A CT-based Monte Carlo simulation tool for dosimetry planning and analysis
    • DeMarco J.J., Solberg T.D., Smathers J.B. A CT-based Monte Carlo simulation tool for dosimetry planning and analysis. Med. Phys. 25:1998;1-11.
    • (1998) Med. Phys. , vol.25 , pp. 1-11
    • Demarco, J.J.1    Solberg, T.D.2    Smathers, J.B.3
  • 13
    • 0027223126 scopus 로고
    • The biological effect of inhomogeneous tumour irradiation with inhomogeneous clonogenic cell density
    • Webb S., Nahum A.E. The biological effect of inhomogeneous tumour irradiation with inhomogeneous clonogenic cell density. Phys. Med. Biol. 38:1993;653-666.
    • (1993) Phys. Med. Biol. , vol.38 , pp. 653-666
    • Webb, S.1    Nahum, A.E.2
  • 14
    • 0001707023 scopus 로고
    • Complication probability as assumed from dose-volume histograms
    • Lyman J.T. Complication probability as assumed from dose-volume histograms. Radiat. Res. 104:1985;513-519.
    • (1985) Radiat. Res. , vol.104 , pp. 513-519
    • Lyman, J.T.1
  • 15
    • 0025939587 scopus 로고
    • Tolerance of normal tissue to therapeutic radiation
    • Emami B., Lyman J., et al. Tolerance of normal tissue to therapeutic radiation. Int. J. Radiat. Oncol. Biol. Phys. 21:1991;109-122.
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.21 , pp. 109-122
    • Emami, B.1    Lyman, J.2
  • 16
    • 0026093854 scopus 로고
    • Histogram reduction method for calculation complication probabilities for three dimensional treatment planning evaluations
    • Kutcher G.J., Burman C., et al. Histogram reduction method for calculation complication probabilities for three dimensional treatment planning evaluations. Int. J. Radiat. Oncol. Biol. Phys. 21:1991;137-146.
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.21 , pp. 137-146
    • Kutcher, G.J.1    Burman, C.2
  • 17
    • 0029120085 scopus 로고
    • A Monte Carlo model of photon beam used in radiation therapy
    • Lovelock D.M.J., Chui C.S., Mohan R. A Monte Carlo model of photon beam used in radiation therapy. Med. Phys. 22:1995;1387-1394.
    • (1995) Med. Phys. , vol.22 , pp. 1387-1394
    • Lovelock, D.M.J.1    Chui, C.S.2    Mohan, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.