-
1
-
-
38149052992
-
Estimates of the prevalence of arthritis and other rheumatic conditions in the United States. Part II
-
Lawrence RC, Felson DT, Helmick CG, et al. Estimates of the prevalence of arthritis and other rheumatic conditions in the United States. Part II. Arthritis Rheum 2008;58:26-35.
-
(2008)
Arthritis Rheum
, vol.58
, pp. 26-35
-
-
Lawrence, R.C.1
Felson, D.T.2
Helmick, C.G.3
-
4
-
-
33745124034
-
MRI protocols for whole-organ assessment of the knee in osteoarthritis
-
Peterfy CG, Gold G, Eckstein F, Cicuttini F, Dardzinski B, Stevens R. MRI protocols for whole-organ assessment of the knee in osteoarthritis. Osteoarthritis Cartilage 2006;14(Suppl A):A95-111.
-
(2006)
Osteoarthritis Cartilage
, vol.14
, Issue.SUPPL. A
-
-
Peterfy, C.G.1
Gold, G.2
Eckstein, F.3
Cicuttini, F.4
Dardzinski, B.5
Stevens, R.6
-
5
-
-
39549091704
-
Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: Preliminary study
-
Duc SR, Pfirrmann CW, Koch PP, Zanetti M, Hodler J. Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: preliminary study. Radiology 2008;246:526-535.
-
(2008)
Radiology
, vol.246
, pp. 526-535
-
-
Duc, S.R.1
Pfirrmann, C.W.2
Koch, P.P.3
Zanetti, M.4
Hodler, J.5
-
6
-
-
31144467037
-
Articular cartilage of the knee: Evaluation with fluctuating equilibrium MR imaging - Initial experience in healthy volunteers
-
Gold GE, Hargreaves BA, Vasanawala SS, et al. Articular cartilage of the knee: evaluation with fluctuating equilibrium MR imaging - initial experience in healthy volunteers. Radiology 2006;238:712-718.
-
(2006)
Radiology
, vol.238
, pp. 712-718
-
-
Gold, G.E.1
Hargreaves, B.A.2
Vasanawala, S.S.3
-
8
-
-
34547762645
-
Effect of multi-slice acquisition on T1 and T2 measurements of articular cartilage at 3T
-
Watanabe A, Boesch C, Obata T, Anderson SE. Effect of multi-slice acquisition on T1 and T2 measurements of articular cartilage at 3T. J Magn Reson Imaging 2007;26:109-117.
-
(2007)
J Magn Reson Imaging
, vol.26
, pp. 109-117
-
-
Watanabe, A.1
Boesch, C.2
Obata, T.3
Anderson, S.E.4
-
9
-
-
0030004409
-
Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy
-
Disler DG, McCauley TR, Kelman CG, et al. Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: comparison with standard MR imaging and arthroscopy. AJR Am J Roentgenol 1996;167:127-132.
-
(1996)
AJR Am J Roentgenol
, vol.167
, pp. 127-132
-
-
Disler, D.G.1
McCauley, T.R.2
Kelman, C.G.3
-
10
-
-
0030090546
-
Optimization of a dual echo in the steady state (DESS) free-precession sequence for imaging cartilage
-
Hardy PA, Recht MP, Piraino D, Thomasson D. Optimization of a dual echo in the steady state (DESS) free-precession sequence for imaging cartilage. J Magn Reson Imaging 1996;6:329-335.
-
(1996)
J Magn Reson Imaging
, vol.6
, pp. 329-335
-
-
Hardy, P.A.1
Recht, M.P.2
Piraino, D.3
Thomasson, D.4
-
11
-
-
55349138378
-
The osteoarthritis initiative: Report on the design rationale for the magnetic resonance imaging protocol for the knee
-
Peterfy CG, Schneider E, Nevitt M. The osteoarthritis initiative: report on the design rationale for the magnetic resonance imaging protocol for the knee. Osteoarthritis Cartilage 2008;16:1433-1441.
-
(2008)
Osteoarthritis Cartilage
, vol.16
, pp. 1433-1441
-
-
Peterfy, C.G.1
Schneider, E.2
Nevitt, M.3
-
12
-
-
0032796073
-
Magnetic resonance imaging of superficial cartilage lesions: Role of contrast in lesion detection
-
Mosher TJ, Pruett SW. Magnetic resonance imaging of superficial cartilage lesions: role of contrast in lesion detection. J Magn Reson Imaging 1999;10:178-182.
-
(1999)
J Magn Reson Imaging
, vol.10
, pp. 178-182
-
-
Mosher, T.J.1
Pruett, S.W.2
-
13
-
-
0037381033
-
Comparison of new sequences for high-resolution cartilage imaging
-
Hargreaves BA, Gold GE, Beaulieu CF, Vasanawala SS, Nishimura DG, Pauly JM. Comparison of new sequences for high-resolution cartilage imaging. Magn Reson Med 2003;49:700-709.
-
(2003)
Magn Reson Med
, vol.49
, pp. 700-709
-
-
Hargreaves, B.A.1
Gold, G.E.2
Beaulieu, C.F.3
Vasanawala, S.S.4
Nishimura, D.G.5
Pauly, J.M.6
-
14
-
-
33646449765
-
Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast
-
Busse RF, Hariharan H, Vu A, Brittain JH. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magn Reson Med 2006;55:1030-1037.
-
(2006)
Magn Reson Med
, vol.55
, pp. 1030-1037
-
-
Busse, R.F.1
Hariharan, H.2
Vu, A.3
Brittain, J.H.4
-
15
-
-
33745728327
-
Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imaging
-
Kijowski R, Lu A, Block W, Grist T. Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imaging. J Magn Reson Imaging 2006;24:168-175.
-
(2006)
J Magn Reson Imaging
, vol.24
, pp. 168-175
-
-
Kijowski, R.1
Lu, A.2
Block, W.3
Grist, T.4
-
16
-
-
26844562367
-
Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition
-
DOI 10.1002/mrm.20654
-
Yu H, Reeder SB, Shimakawa A, Brittain JH, Pelc NJ. Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition. Magn Reson Med 2005;54:1032-1039. (Pubitemid 41457077)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.4
, pp. 1032-1039
-
-
Yu, H.1
Reeder, S.B.2
Shimakawa, A.3
Brittain, J.H.4
Pelc, N.J.5
-
18
-
-
84925567627
-
Unspoiled gradient recalled-echo acquired in the steady-state (GRASS) with IDEAL fat-suppression for high resolution cartilage imaging at 3T
-
Abstract 3819
-
Kijowski R, Passov L, Shimakawa A, Yu H, Reeder S. Unspoiled gradient recalled-echo acquired in the steady-state (GRASS) with IDEAL fat-suppression for high resolution cartilage imaging at 3T. In: Proc 15th Annual Meeting ISMRM, Berlin; 2007 (Abstract 3819).
-
Proc 15th Annual Meeting ISMRM, Berlin; 2007
-
-
Kijowski, R.1
Passov, L.2
Shimakawa, A.3
Yu, H.4
Reeder, S.5
-
19
-
-
0023865001
-
FADE - A new fast imaging sequence
-
Redpath TW, Jones RA. FADE - a new fast imaging sequence. Magn Reson Med 1988;6:224-234.
-
(1988)
Magn Reson Med
, vol.6
, pp. 224-234
-
-
Redpath, T.W.1
Jones, R.A.2
-
20
-
-
77954091436
-
Quantitative and qualitative evaluation of coherent oscillatory state acquisition for the manipulation of image contrast (COSMIC) in cervical spine myelographic magnetic resonance imaging
-
Society of Skeletal Radiology 2008 Annual Meeting, La Quinta, CA. (Abstract 13)
-
Huang TL, Ogino S, Bittersohl B, Vu AT, Lang PK, Yoshioka H. Quantitative and qualitative evaluation of coherent oscillatory state acquisition for the manipulation of image contrast (COSMIC) in cervical spine myelographic magnetic resonance imaging. Society of Skeletal Radiology 2008 Annual Meeting, La Quinta, CA. Skeletal Radiol 2008;37:377 (Abstract 13).
-
(2008)
Skeletal Radiol
, vol.37
, pp. 377
-
-
Huang, T.L.1
Ogino, S.2
Bittersohl, B.3
Vu, A.T.4
Lang, P.K.5
Yoshioka, H.6
-
21
-
-
38949156006
-
A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times
-
Abstract 1749
-
Beatty PJ, Brau AC, Chang S, et al. A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times. In: Proc 15th Annual Meeting ISMRM, Berlin; 2007 (Abstract 1749).
-
Proc 15th Annual Meeting ISMRM, Berlin; 2007
-
-
Beatty, P.J.1
Brau, A.C.2
Chang, S.3
-
22
-
-
24144470505
-
Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: Application with cardiac imaging and a 32-channel cardiac coil
-
DOI 10.1002/mrm.20636
-
Reeder SB, Wintersperger BJ, Dietrich O, et al. Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil. Magn Reson Med 2005;54:748-754. (Pubitemid 41233774)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.3
, pp. 748-754
-
-
Reeder, S.B.1
Wintersperger, B.J.2
Dietrich, O.3
Lanz, T.4
Greiser, A.5
Reiser, M.F.6
Glazer, G.M.7
Schoenberg, S.O.8
-
23
-
-
34247555294
-
Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): Initial experience
-
DOI 10.2214/AJR.06.1208
-
Gold GE, Busse RF, Beehler C, et al. Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. AJR Am J Roentgenol 2007;188:1287-1293. (Pubitemid 46668510)
-
(2007)
American Journal of Roentgenology
, vol.188
, Issue.5
, pp. 1287-1293
-
-
Gold, G.E.1
Busse, R.F.2
Beehler, C.3
Han, E.4
Brau, A.C.S.5
Beatty, P.J.6
Beaulieu, C.F.7
-
24
-
-
70249113016
-
Knee joint: Comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging - Diagnostic performance compared with that of conventional MR imaging at 3.0 T
-
Kijowski R, Davis KW, Woods MA, et al. Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging - diagnostic performance compared with that of conventional MR imaging at 3.0 T. Radiology 2009;252:486-495.
-
(2009)
Radiology
, vol.252
, pp. 486-495
-
-
Kijowski, R.1
Davis, K.W.2
Woods, M.A.3
-
26
-
-
0031756757
-
MRI of patellar articular cartilage: Evaluation of an optimized gradient-echo sequence (3D-DESS)
-
Ruehm S, Zanetti M, Romero J, Hodler J. MRI of patellar articular cartilage: evaluation of an optimized gradient echo sequence (3D-DESS). J Magn Reson Imaging 1998;8:1246-1251. (Pubitemid 28533668)
-
(1998)
Journal of Magnetic Resonance Imaging
, vol.8
, Issue.6
, pp. 1246-1251
-
-
Ruehm, S.1
Zanetti, M.2
Romero, J.3
Hodler, J.4
-
27
-
-
24144483103
-
Cramer-Rao bounds for three-point decomposition of water and fat
-
DOI 10.1002/mrm.20623
-
Pineda AR, Reeder SB, Wen Z, Pelc NJ. Cramer-Rao bounds for three-point decomposition of water and fat. Magn Reson Med 2005;54:625-635. (Pubitemid 41233757)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.3
, pp. 625-635
-
-
Pineda, A.R.1
Reeder, S.B.2
Wen, Z.3
Pelc, N.J.4
-
28
-
-
0031866441
-
Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging
-
Eckstein F, Schnier M, Haubner M, et al. Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging. Clin Orthop Relat Res 1998:137-148. (Pubitemid 28326293)
-
(1998)
Clinical Orthopaedics and Related Research
, Issue.352
, pp. 137-148
-
-
Eckstein, F.1
Schnier, M.2
Haubner, M.3
Priebsch, J.4
Glaser, C.5
Englmeier, K.-H.6
Reiser, M.7
-
29
-
-
0034232664
-
Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume
-
Cicuttini F, Forbes A, Asbeutah A, Morris K, Stuckey S. Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume. J Orthop Res 2000;18:580-584.
-
(2000)
J Orthop Res
, vol.18
, pp. 580-584
-
-
Cicuttini, F.1
Forbes, A.2
Asbeutah, A.3
Morris, K.4
Stuckey, S.5
-
30
-
-
0033136254
-
Gender differences in knee cartilage volume as measured by magnetic resonance imaging
-
DOI 10.1053/joca.1998.0200
-
Cicuttini F, Forbes A, Morris K, Darling S, Bailey M, Stuckey S. Gender differences in knee cartilage volume as measured by magnetic resonance imaging. Osteoarthritis Cartilage 1999;7:265-271. (Pubitemid 29244100)
-
(1999)
Osteoarthritis and Cartilage
, vol.7
, Issue.3
, pp. 265-271
-
-
Cicuttini, F.1
Forbes, A.2
Morris, K.3
Darling, S.4
Bailey, M.5
Stuckey, S.6
-
31
-
-
0031929722
-
In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging
-
Eckstein F, Westhoff J, Sittek H, et al. In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging. AJR Am J Roentgenol 1998;170:593-597.
-
(1998)
AJR Am J Roentgenol
, vol.170
, pp. 593-597
-
-
Eckstein, F.1
Westhoff, J.2
Sittek, H.3
-
32
-
-
3242803606
-
Musculoskeletal MRI at 3.0 T: Relaxation times and image contrast
-
Gold GE, Han E, Stainsby J, Wright G, Brittain J, Beaulieu C. Musculoskeletal MRI at 3.0 T: relaxation times and image contrast. AJR Am J Roentgenol 2004;183:343-351.
-
(2004)
AJR Am J Roentgenol
, vol.183
, pp. 343-351
-
-
Gold, G.E.1
Han, E.2
Stainsby, J.3
Wright, G.4
Brittain, J.5
Beaulieu, C.6
|