메뉴 건너뛰기




Volumn 32, Issue 1, 2010, Pages 173-183

Cartilage morphology at 3.0T: Assessment of three-dimensional magnetic resonance imaging techniques

Author keywords

Cartilage; FSE Cube; IDEAL; Knee; Magnetic resonance imaging

Indexed keywords

ACCURACY; ADULT; ARTICLE; CARTILAGE; CLINICAL ARTICLE; COHERENT OSCILLATORY STATE ACQUISITION FOR MANIPULATION OF IMAGE CONTRAST IMAGING; CONTRAST SENSITIVITY; CONTROLLED STUDY; FAST SPIN ECHO CUBE IMAGING; FEMALE; GRADIENT ECHO; HUMAN; INTERMETHOD COMPARISON; ITERATIVE DECOMPOSITION OF WATER AND FAT WITH ECHO ASSYMETRY AND LEAST SQUARES ESTIMATION COMBINED WITH SPOILED GRADIENT ECHO IMAGING; KNEE; LESION CONSPICUITY; MALE; MORPHOLOGY; MULTIECHO IN STEADY STATE ACQUISITION; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOARTHRITIS; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; REFORMAT QUALITY; SEQUENCE ANALYSIS; SIGNAL NOISE RATIO; SURFACE PROPERTY; THREE DIMENSIONAL IMAGING; VASTLY UNDERSAMPLED ISOTROPIC PROJECTION RECONSTRUCTION BALANCED STEADY STATE FREE PRECESSION IMAGING; VOLUMETRY; ANATOMY AND HISTOLOGY; ARTICULAR CARTILAGE; IMAGE PROCESSING; OBSERVER VARIATION; PROCEDURES; PROSPECTIVE STUDY; REFERENCE VALUE; REPRODUCIBILITY;

EID: 77954104644     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22213     Document Type: Article
Times cited : (36)

References (32)
  • 1
    • 38149052992 scopus 로고    scopus 로고
    • Estimates of the prevalence of arthritis and other rheumatic conditions in the United States. Part II
    • Lawrence RC, Felson DT, Helmick CG, et al. Estimates of the prevalence of arthritis and other rheumatic conditions in the United States. Part II. Arthritis Rheum 2008;58:26-35.
    • (2008) Arthritis Rheum , vol.58 , pp. 26-35
    • Lawrence, R.C.1    Felson, D.T.2    Helmick, C.G.3
  • 5
    • 39549091704 scopus 로고    scopus 로고
    • Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: Preliminary study
    • Duc SR, Pfirrmann CW, Koch PP, Zanetti M, Hodler J. Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: preliminary study. Radiology 2008;246:526-535.
    • (2008) Radiology , vol.246 , pp. 526-535
    • Duc, S.R.1    Pfirrmann, C.W.2    Koch, P.P.3    Zanetti, M.4    Hodler, J.5
  • 6
    • 31144467037 scopus 로고    scopus 로고
    • Articular cartilage of the knee: Evaluation with fluctuating equilibrium MR imaging - Initial experience in healthy volunteers
    • Gold GE, Hargreaves BA, Vasanawala SS, et al. Articular cartilage of the knee: evaluation with fluctuating equilibrium MR imaging - initial experience in healthy volunteers. Radiology 2006;238:712-718.
    • (2006) Radiology , vol.238 , pp. 712-718
    • Gold, G.E.1    Hargreaves, B.A.2    Vasanawala, S.S.3
  • 8
    • 34547762645 scopus 로고    scopus 로고
    • Effect of multi-slice acquisition on T1 and T2 measurements of articular cartilage at 3T
    • Watanabe A, Boesch C, Obata T, Anderson SE. Effect of multi-slice acquisition on T1 and T2 measurements of articular cartilage at 3T. J Magn Reson Imaging 2007;26:109-117.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 109-117
    • Watanabe, A.1    Boesch, C.2    Obata, T.3    Anderson, S.E.4
  • 9
    • 0030004409 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy
    • Disler DG, McCauley TR, Kelman CG, et al. Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: comparison with standard MR imaging and arthroscopy. AJR Am J Roentgenol 1996;167:127-132.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 127-132
    • Disler, D.G.1    McCauley, T.R.2    Kelman, C.G.3
  • 10
    • 0030090546 scopus 로고    scopus 로고
    • Optimization of a dual echo in the steady state (DESS) free-precession sequence for imaging cartilage
    • Hardy PA, Recht MP, Piraino D, Thomasson D. Optimization of a dual echo in the steady state (DESS) free-precession sequence for imaging cartilage. J Magn Reson Imaging 1996;6:329-335.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 329-335
    • Hardy, P.A.1    Recht, M.P.2    Piraino, D.3    Thomasson, D.4
  • 11
    • 55349138378 scopus 로고    scopus 로고
    • The osteoarthritis initiative: Report on the design rationale for the magnetic resonance imaging protocol for the knee
    • Peterfy CG, Schneider E, Nevitt M. The osteoarthritis initiative: report on the design rationale for the magnetic resonance imaging protocol for the knee. Osteoarthritis Cartilage 2008;16:1433-1441.
    • (2008) Osteoarthritis Cartilage , vol.16 , pp. 1433-1441
    • Peterfy, C.G.1    Schneider, E.2    Nevitt, M.3
  • 12
    • 0032796073 scopus 로고    scopus 로고
    • Magnetic resonance imaging of superficial cartilage lesions: Role of contrast in lesion detection
    • Mosher TJ, Pruett SW. Magnetic resonance imaging of superficial cartilage lesions: role of contrast in lesion detection. J Magn Reson Imaging 1999;10:178-182.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 178-182
    • Mosher, T.J.1    Pruett, S.W.2
  • 14
    • 33646449765 scopus 로고    scopus 로고
    • Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast
    • Busse RF, Hariharan H, Vu A, Brittain JH. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magn Reson Med 2006;55:1030-1037.
    • (2006) Magn Reson Med , vol.55 , pp. 1030-1037
    • Busse, R.F.1    Hariharan, H.2    Vu, A.3    Brittain, J.H.4
  • 15
    • 33745728327 scopus 로고    scopus 로고
    • Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imaging
    • Kijowski R, Lu A, Block W, Grist T. Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imaging. J Magn Reson Imaging 2006;24:168-175.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 168-175
    • Kijowski, R.1    Lu, A.2    Block, W.3    Grist, T.4
  • 16
    • 26844562367 scopus 로고    scopus 로고
    • Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition
    • DOI 10.1002/mrm.20654
    • Yu H, Reeder SB, Shimakawa A, Brittain JH, Pelc NJ. Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition. Magn Reson Med 2005;54:1032-1039. (Pubitemid 41457077)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.4 , pp. 1032-1039
    • Yu, H.1    Reeder, S.B.2    Shimakawa, A.3    Brittain, J.H.4    Pelc, N.J.5
  • 17
  • 18
    • 84925567627 scopus 로고    scopus 로고
    • Unspoiled gradient recalled-echo acquired in the steady-state (GRASS) with IDEAL fat-suppression for high resolution cartilage imaging at 3T
    • Abstract 3819
    • Kijowski R, Passov L, Shimakawa A, Yu H, Reeder S. Unspoiled gradient recalled-echo acquired in the steady-state (GRASS) with IDEAL fat-suppression for high resolution cartilage imaging at 3T. In: Proc 15th Annual Meeting ISMRM, Berlin; 2007 (Abstract 3819).
    • Proc 15th Annual Meeting ISMRM, Berlin; 2007
    • Kijowski, R.1    Passov, L.2    Shimakawa, A.3    Yu, H.4    Reeder, S.5
  • 19
    • 0023865001 scopus 로고
    • FADE - A new fast imaging sequence
    • Redpath TW, Jones RA. FADE - a new fast imaging sequence. Magn Reson Med 1988;6:224-234.
    • (1988) Magn Reson Med , vol.6 , pp. 224-234
    • Redpath, T.W.1    Jones, R.A.2
  • 20
    • 77954091436 scopus 로고    scopus 로고
    • Quantitative and qualitative evaluation of coherent oscillatory state acquisition for the manipulation of image contrast (COSMIC) in cervical spine myelographic magnetic resonance imaging
    • Society of Skeletal Radiology 2008 Annual Meeting, La Quinta, CA. (Abstract 13)
    • Huang TL, Ogino S, Bittersohl B, Vu AT, Lang PK, Yoshioka H. Quantitative and qualitative evaluation of coherent oscillatory state acquisition for the manipulation of image contrast (COSMIC) in cervical spine myelographic magnetic resonance imaging. Society of Skeletal Radiology 2008 Annual Meeting, La Quinta, CA. Skeletal Radiol 2008;37:377 (Abstract 13).
    • (2008) Skeletal Radiol , vol.37 , pp. 377
    • Huang, T.L.1    Ogino, S.2    Bittersohl, B.3    Vu, A.T.4    Lang, P.K.5    Yoshioka, H.6
  • 21
    • 38949156006 scopus 로고    scopus 로고
    • A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times
    • Abstract 1749
    • Beatty PJ, Brau AC, Chang S, et al. A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times. In: Proc 15th Annual Meeting ISMRM, Berlin; 2007 (Abstract 1749).
    • Proc 15th Annual Meeting ISMRM, Berlin; 2007
    • Beatty, P.J.1    Brau, A.C.2    Chang, S.3
  • 24
    • 70249113016 scopus 로고    scopus 로고
    • Knee joint: Comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging - Diagnostic performance compared with that of conventional MR imaging at 3.0 T
    • Kijowski R, Davis KW, Woods MA, et al. Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging - diagnostic performance compared with that of conventional MR imaging at 3.0 T. Radiology 2009;252:486-495.
    • (2009) Radiology , vol.252 , pp. 486-495
    • Kijowski, R.1    Davis, K.W.2    Woods, M.A.3
  • 26
    • 0031756757 scopus 로고    scopus 로고
    • MRI of patellar articular cartilage: Evaluation of an optimized gradient-echo sequence (3D-DESS)
    • Ruehm S, Zanetti M, Romero J, Hodler J. MRI of patellar articular cartilage: evaluation of an optimized gradient echo sequence (3D-DESS). J Magn Reson Imaging 1998;8:1246-1251. (Pubitemid 28533668)
    • (1998) Journal of Magnetic Resonance Imaging , vol.8 , Issue.6 , pp. 1246-1251
    • Ruehm, S.1    Zanetti, M.2    Romero, J.3    Hodler, J.4
  • 27
    • 24144483103 scopus 로고    scopus 로고
    • Cramer-Rao bounds for three-point decomposition of water and fat
    • DOI 10.1002/mrm.20623
    • Pineda AR, Reeder SB, Wen Z, Pelc NJ. Cramer-Rao bounds for three-point decomposition of water and fat. Magn Reson Med 2005;54:625-635. (Pubitemid 41233757)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.3 , pp. 625-635
    • Pineda, A.R.1    Reeder, S.B.2    Wen, Z.3    Pelc, N.J.4
  • 29
    • 0034232664 scopus 로고    scopus 로고
    • Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume
    • Cicuttini F, Forbes A, Asbeutah A, Morris K, Stuckey S. Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume. J Orthop Res 2000;18:580-584.
    • (2000) J Orthop Res , vol.18 , pp. 580-584
    • Cicuttini, F.1    Forbes, A.2    Asbeutah, A.3    Morris, K.4    Stuckey, S.5
  • 30
    • 0033136254 scopus 로고    scopus 로고
    • Gender differences in knee cartilage volume as measured by magnetic resonance imaging
    • DOI 10.1053/joca.1998.0200
    • Cicuttini F, Forbes A, Morris K, Darling S, Bailey M, Stuckey S. Gender differences in knee cartilage volume as measured by magnetic resonance imaging. Osteoarthritis Cartilage 1999;7:265-271. (Pubitemid 29244100)
    • (1999) Osteoarthritis and Cartilage , vol.7 , Issue.3 , pp. 265-271
    • Cicuttini, F.1    Forbes, A.2    Morris, K.3    Darling, S.4    Bailey, M.5    Stuckey, S.6
  • 31
    • 0031929722 scopus 로고    scopus 로고
    • In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging
    • Eckstein F, Westhoff J, Sittek H, et al. In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging. AJR Am J Roentgenol 1998;170:593-597.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 593-597
    • Eckstein, F.1    Westhoff, J.2    Sittek, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.