메뉴 건너뛰기




Volumn 252, Issue 2, 2009, Pages 486-495

Knee joint: Comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging - Diagnostic performance compared with that of conventional MR imaging at 3.0 T

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTHROSCOPIC SURGERY; ARTICLE; ARTICULAR CARTILAGE; BONE MARROW; CLINICAL ASSESSMENT; DIAGNOSTIC IMAGING; FAST SPIN ECHO SEQUENCE NUCLEAR MAGNETIC RESONANCE IMAGING; FEMALE; HUMAN; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; KNEE; KNEE ARTHROSCOPY; KNEE DISEASE; KNEE INJURY; KNEE LIGAMENT; KNEE LIGAMENT INJURY; KNEE MENISCUS; KNEE MENISCUS RUPTURE; KNEE SURGERY; MAJOR CLINICAL STUDY; MALE; MUSCULOSKELETAL INJURY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIODIAGNOSIS; RADIOLOGIST; THREE DIMENSIONAL IMAGING; ADOLESCENT; AGED; ALGORITHM; ANISOTROPY; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; ECHO PLANAR IMAGING; IMAGE ENHANCEMENT; METHODOLOGY; MIDDLE AGED; PATHOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SPIN LABELING;

EID: 70249113016     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.2523090028     Document Type: Article
Times cited : (233)

References (28)
  • 1
    • 0027394087 scopus 로고
    • Multiplanar reconstruction in magnetic resonance evaluation of the knee: Comparison with film magnetic resonance interpretation
    • Gay SB, Chen NC, Burch JJ, Gleason TR, Sagman AM. Multiplanar reconstruction in magnetic resonance evaluation of the knee: comparison with film magnetic resonance interpretation. Invest Radiol 1993;28(2):142-145.
    • (1993) Invest Radiol , vol.28 , Issue.2 , pp. 142-145
    • Gay, S.B.1    Chen, N.C.2    Burch, J.J.3    Gleason, T.R.4    Sagman, A.M.5
  • 2
    • 0032015191 scopus 로고    scopus 로고
    • Multiplanar reconstruction in MR imaging of the knee: Comparison with standard sagittal and coronal images
    • Wieslander SB, Rappeport ED, Lausten GS, Thomsen HS. Multiplanar reconstruction in MR imaging of the knee: comparison with standard sagittal and coronal images. Acta Radiol 1998;39(2):116-119.
    • (1998) Acta Radiol , vol.39 , Issue.2 , pp. 116-119
    • Wieslander, S.B.1    Rappeport, E.D.2    Lausten, G.S.3    Thomsen, H.S.4
  • 3
    • 39549091704 scopus 로고    scopus 로고
    • Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: Preliminary study
    • Duc SR, Pfirrmann CW, Koch PP, Zanetti M, Hodler J. Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: preliminary study. Radiology 2008;246(2):526-535.
    • (2008) Radiology , vol.246 , Issue.2 , pp. 526-535
    • Duc, S.R.1    Pfirrmann, C.W.2    Koch, P.P.3    Zanetti, M.4    Hodler, J.5
  • 4
    • 33745728327 scopus 로고    scopus 로고
    • Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imaging
    • Kijowski R, Lu A, Block W, Grist T. Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imaging. J Magn Reson Imaging 2006;24(1):168-175.
    • (2006) J Magn Reson Imaging , vol.24 , Issue.1 , pp. 168-175
    • Kijowski, R.1    Lu, A.2    Block, W.3    Grist, T.4
  • 5
    • 64949151539 scopus 로고    scopus 로고
    • Vastly undersampled isotropic projection steady-state free precession imaging of the knee: Diagnostic performance compared with conventional MR
    • Kijowski R, Blankenbaker DG, Klaers JL, Shinki K, De Smet AA, Block WF. Vastly undersampled isotropic projection steady-state free precession imaging of the knee: diagnostic performance compared with conventional MR. Radiology 2009;251(1):185-194.
    • (2009) Radiology , vol.251 , Issue.1 , pp. 185-194
    • Kijowski, R.1    Blankenbaker, D.G.2    Klaers, J.L.3    Shinki, K.4    De Smet, A.A.5    Block, W.F.6
  • 6
    • 35148840438 scopus 로고    scopus 로고
    • Diagnostic efficacy in knee MRI comparing conventional technique and multiplanar reconstruction with one-millimeter FSE PDW images
    • Yoon YC, Kim SS, Chung HW, Choe BK, Ahn JH. Diagnostic efficacy in knee MRI comparing conventional technique and multiplanar reconstruction with one-millimeter FSE PDW images. Acta Radiol 2007;48(8):869-874.
    • (2007) Acta Radiol , vol.48 , Issue.8 , pp. 869-874
    • Yoon, Y.C.1    Kim, S.S.2    Chung, H.W.3    Choe, B.K.4    Ahn, J.H.5
  • 7
    • 51449085600 scopus 로고    scopus 로고
    • Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    • Busse RF, Brau AC, Vu A, et al. Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 2008;60(3):640-649.
    • (2008) Magn Reson Med , vol.60 , Issue.3 , pp. 640-649
    • Busse, R.F.1    Brau, A.C.2    Vu, A.3
  • 8
    • 33646449765 scopus 로고    scopus 로고
    • Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast
    • Busse RF, Hariharan H, Vu A, Brittain JH. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magn Reson Med 2006;55(5):1030-1037.
    • (2006) Magn Reson Med , vol.55 , Issue.5 , pp. 1030-1037
    • Busse, R.F.1    Hariharan, H.2    Vu, A.3    Brittain, J.H.4
  • 10
    • 0024415632 scopus 로고
    • A system for grading articular cartilage lesions at arthroscopy
    • Noyes FR, Stabler CL. A system for grading articular cartilage lesions at arthroscopy. Am J Sports Med 1989;17(4):505-513.
    • (1989) Am J Sports Med , vol.17 , Issue.4 , pp. 505-513
    • Noyes, F.R.1    Stabler, C.L.2
  • 11
    • 0032753277 scopus 로고    scopus 로고
    • Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients
    • Bredella MA, Tirman PF, Peterfy CG, et al. Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients. AJR Am J Roentgenol 1999;172(4):1073-1080.
    • (1999) AJR Am J Roentgenol , vol.172 , Issue.4 , pp. 1073-1080
    • Bredella, M.A.1    Tirman, P.F.2    Peterfy, C.G.3
  • 13
    • 0036839060 scopus 로고    scopus 로고
    • Grading articular cartilage of the knee using fast spin-echo proton density-weighted MR imaging without fat suppression
    • Sonin AH, Pensy RA, Mulligan ME, Hatem S. Grading articular cartilage of the knee using fast spin-echo proton density-weighted MR imaging without fat suppression. AJR Am J Roentgenol 2002;179(5):1159-1166. (Pubitemid 35204367)
    • (2002) American Journal of Roentgenology , vol.179 , Issue.5 , pp. 1159-1166
    • Sonin, A.H.1    Pensy, R.A.2    Mulligan, M.E.3    Hatem, S.4
  • 14
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33(1):159-174.
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 16
    • 0030992209 scopus 로고    scopus 로고
    • Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients
    • Cheung LP, Li KC, Hollett MD, Bergman AG, Herfkens RJ. Meniscal tears of the knee: accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients. Radiology 1997;203(2):508-512.
    • (1997) Radiology , vol.203 , Issue.2 , pp. 508-512
    • Cheung, L.P.1    Li, K.C.2    Hollett, M.D.3    Bergman, A.G.4    Herfkens, R.J.5
  • 17
    • 0031896508 scopus 로고    scopus 로고
    • Anterior cruciate ligament injury: Fast spin-echo MR imaging with arthroscopic correlation in 217 examinations
    • Ha TP, Li KC, Beaulieu CF, et al. Anterior cruciate ligament injury: fast spin-echo MR imaging with arthroscopic correlation in 217 examinations. AJR Am J Roentgenol 1998;170(5):1215-1219.
    • (1998) AJR Am J Roentgenol , vol.170 , Issue.5 , pp. 1215-1219
    • Ha, T.P.1    Li, K.C.2    Beaulieu, C.F.3
  • 18
    • 33747444555 scopus 로고    scopus 로고
    • Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions-Comparison to arthroscopy
    • DOI 10.1016/j.ejrad.2005.12.034, PII S0720048X06000064
    • Schaefer FK, Schaefer PJ, Brossmann J, et al. Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions: comparison to arthroscopy. Eur J Radiol 2006;58(3):411-415. (Pubitemid 44250886)
    • (2006) European Journal of Radiology , vol.58 , Issue.3 , pp. 411-415
    • Schaefer, F.K.W.1    Schaefer, P.J.2    Brossmann, J.3    Frahm, C.4    Muhle, C.5    Hilgert, R.E.6    Heller, M.7    Jahnke, T.8
  • 19
    • 0029910595 scopus 로고    scopus 로고
    • Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: Comparison with a conventional spin-echo sequence
    • Escobedo EM, Hunter JC, Zink-Brody GC, Wilson AJ, Harrison SD, Fisher DJ. Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: comparison with a conventional spin-echo sequence. AJR Am J Roentgenol 1996;167(5):1223-1227.
    • (1996) AJR Am J Roentgenol , vol.167 , Issue.5 , pp. 1223-1227
    • Escobedo, E.M.1    Hunter, J.C.2    Zink-Brody, G.C.3    Wilson, A.J.4    Harrison, S.D.5    Fisher, D.J.6
  • 20
    • 0028910292 scopus 로고
    • Medial collateral ligament injuries: Evaluation of multiple signs, prevalence and location of associated bone bruises, and assessment with MR imaging
    • Schweitzer ME, Tran D, Deely DM, Hume EL. Medial collateral ligament injuries: evaluation of multiple signs, prevalence and location of associated bone bruises, and assessment with MR imaging. Radiology 1995;194(3):825-829.
    • (1995) Radiology , vol.194 , Issue.3 , pp. 825-829
    • Schweitzer, M.E.1    Tran, D.2    Deely, D.M.3    Hume, E.L.4
  • 21
    • 0037973576 scopus 로고    scopus 로고
    • Using fat-saturated proton density-weighted MR imaging to evaluate articular cartilage [6] (multiple letters)
    • Mohr A, Roemer FW, Genant HK, Liess C. Using fat-saturated proton density-weighted MR imaging to evaluate articular cartilage [letter]. AJR Am J Roentgenol 2003;181(1):280-281. (Pubitemid 36741506)
    • (2003) American Journal of Roentgenology , vol.181 , Issue.1 , pp. 280-282
    • Mohr, A.1    Roemer, F.W.2    Genant, H.K.3    Liess, C.4    Sonin, A.5
  • 22
    • 0042173132 scopus 로고    scopus 로고
    • The value of water-excitation 3D FLASH and fat-saturated PDw TSE MR imaging for detecting and grading articular cartilage lesions of the knee
    • DOI 10.1007/s00256-003-0635-z
    • Mohr A. The value of water-excitation 3D FLASH and fat-saturated PDw TSE MR imaging for detecting and grading articular cartilage lesions of the knee. Skeletal Radiol 2003;32(7):396-402. (Pubitemid 36926625)
    • (2003) Skeletal Radiology , vol.32 , Issue.7 , pp. 396-402
    • Mohr, A.1
  • 23
    • 0032772878 scopus 로고    scopus 로고
    • Posteromedial corner of the knee: MR imaging with gross anatomic correlation
    • DOI 10.1007/s002560050522
    • Loredo R, Hodler J, Pedowitz R, Yeh LR, Trudell D, Resnick D. Posteromedial corner of the knee: MR imaging with gross anatomic correlation. Skeletal Radiol 1999;28(6):305-311. (Pubitemid 29358783)
    • (1999) Skeletal Radiology , vol.28 , Issue.6 , pp. 305-311
    • Loredo, R.1    Hodler, J.2    Pedowitz, R.3    Yeh, L.-R.4    Trudell, D.5    Resnick, D.6
  • 24
    • 0030028252 scopus 로고    scopus 로고
    • Posterolateral aspect of the knee: Improved MR imaging with a coronal oblique technique
    • Yu JS, Salonen DC, Hodler J, Haghighi P, Trudell D, Resnick D. Posterolateral aspect of the knee: improved MR imaging with a coronal oblique technique. Radiology 1996;198(1):199-204. (Pubitemid 26008264)
    • (1996) Radiology , vol.198 , Issue.1 , pp. 199-204
    • Yu, J.S.1    Salonen, D.C.2    Hodler, J.3    Haghighi, P.4    Trudell, D.5    Resnick, D.6
  • 25
    • 36148997626 scopus 로고    scopus 로고
    • MRI of the popliteofibular ligament: Isotropic 3D WE-DESS versus coronal oblique fat-suppressed T2W MRI
    • DOI 10.1007/s00256-007-0385-4
    • Rajeswaran G, Lee JC, Healy JC. MRI of the popliteofibular ligament: isotropic 3D WE-DESS versus coronal oblique fat-suppressed T2W MRI. Skeletal Radiol 2007;36(12):1141-1146. (Pubitemid 350112380)
    • (2007) Skeletal Radiology , vol.36 , Issue.12 , pp. 1141-1146
    • Rajeswaran, G.1    Lee, J.C.2    Healy, J.C.3
  • 26
    • 20044393046 scopus 로고    scopus 로고
    • Comparison of fast spin-echo versus conventional spin-echo MRI for evaluating meniscal tears
    • Blackmon GB, Major NM, Helms CA. Comparison of fast spin-echo versus conventional spin-echo MRI for evaluating meniscal tears. AJR Am J Roentgenol 2005;184(6):1740-1743.
    • (2005) AJR Am J Roentgenol , vol.184 , Issue.6 , pp. 1740-1743
    • Blackmon, G.B.1    Major, N.M.2    Helms, C.A.3
  • 28
    • 58149196705 scopus 로고    scopus 로고
    • Ankle: Isotropic MR imaging with 3D-FSE-Cube - Initial experience in healthy volunteers
    • Stevens KJ, Busse RF, Han E, et al. Ankle: isotropic MR imaging with 3D-FSE-Cube - initial experience in healthy volunteers. Radiology 2008;249(3):1026-1033.
    • (2008) Radiology , vol.249 , Issue.3 , pp. 1026-1033
    • Stevens, K.J.1    Busse, R.F.2    Han, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.