메뉴 건너뛰기




Volumn 238, Issue 2, 2006, Pages 712-718

Articular cartilage of the knee: Evaluation with fluctuating equilibrium MR imaging - Initial experience in healthy volunteers

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANALYTICAL PARAMETERS; ARTICLE; ARTICULAR CARTILAGE; ARTIFACT REDUCTION; CARTILAGE FLUID; CARTILAGE VISIBILITY; CLINICAL TRIAL; FAT SUPPRESSION; FEMALE; FLUCTUATING EQUILIBRIUM MAGNETIC RESONANCE IMAGING; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; KNEE; KNEE CARTILAGE; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OPTICAL RESOLUTION; PRIORITY JOURNAL; SIGNAL NOISE RATIO; SIGNAL NOISE RATIO EFFICIENCY; TECHNIQUE; THREE DIMENSIONAL IMAGING; THREE DIMENSIONAL SPOILED GRADIENT RECALLED ACQUISITION IN THE STEADY STATE; TISSUE WATER; TWO DIMENSIONAL FAST SPIN ECHO; VOLUMETRY;

EID: 31144467037     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2381042183     Document Type: Article
Times cited : (48)

References (24)
  • 1
    • 0033775218 scopus 로고    scopus 로고
    • Osteoarthritis: New insights. I. The disease and its risk factors
    • Felson DT, Lawrence RC, Dieppe PA, et al. Osteoarthritis: new insights. I. The disease and its risk factors. Ann Intern Med 2000;133:635-646.
    • (2000) Ann Intern Med , vol.133 , pp. 635-646
    • Felson, D.T.1    Lawrence, R.C.2    Dieppe, P.A.3
  • 2
    • 0030984427 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional spoiled gradient-recalled MR imaging: Assessment of articular and physeal hyaline cartilage
    • Disler DG. Fat-suppressed three-dimensional spoiled gradient-recalled MR imaging: assessment of articular and physeal hyaline cartilage. AJR Am J Roentgenol 1997;169:1117-1123.
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 1117-1123
    • Disler, D.G.1
  • 3
    • 0030043124 scopus 로고    scopus 로고
    • Accuracy of fat-suppressed three-dimensional spoiled gradient-echo FLASH MR imaging in the detection of patellofemoral articular cartilage abnormalities
    • Recht MP, Piraino DW, Paletta GA, Schils JP, Belhobek GH. Accuracy of fat-suppressed three-dimensional spoiled gradient-echo FLASH MR imaging in the detection of patellofemoral articular cartilage abnormalities. Radiology 1996;198:209-212.
    • (1996) Radiology , vol.198 , pp. 209-212
    • Recht, M.P.1    Piraino, D.W.2    Paletta, G.A.3    Schils, J.P.4    Belhobek, G.H.5
  • 4
    • 0032867346 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional fast spoiled gradient-recalled echo imaging: A modified FS 3D SPGR technique for assessment of patellofemoral joint chondromalacia
    • Wang SF, Cheng HC, Chang CY. Fat-suppressed three-dimensional fast spoiled gradient-recalled echo imaging: a modified FS 3D SPGR technique for assessment of patellofemoral joint chondromalacia. Clin Imaging 1999;23:177-180.
    • (1999) Clin Imaging , vol.23 , pp. 177-180
    • Wang, S.F.1    Cheng, H.C.2    Chang, C.Y.3
  • 5
    • 0031659416 scopus 로고    scopus 로고
    • Magnetic resonance imaging of articular cartilage in the knee: An evaluation with use of fast-spin-echo imaging
    • Potter HG, Linklater JM, Allen AA, Hannafin JA, Haas SB. Magnetic resonance imaging of articular cartilage in the knee: an evaluation with use of fast-spin-echo imaging. J Bone Joint Surg Am 1998;80:1276-1284.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1276-1284
    • Potter, H.G.1    Linklater, J.M.2    Allen, A.A.3    Hannafin, J.A.4    Haas, S.B.5
  • 6
    • 0030910660 scopus 로고    scopus 로고
    • Short echo time projection reconstruction MR imaging of cartilage: Comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging
    • Brossmann J, Frank LR, Pauly JM, et al. Short echo time projection reconstruction MR imaging of cartilage: comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging. Radiology 1997;203:501-507.
    • (1997) Radiology , vol.203 , pp. 501-507
    • Brossmann, J.1    Frank, L.R.2    Pauly, J.M.3
  • 7
    • 0032065442 scopus 로고    scopus 로고
    • MR imaging of articular cartilage of the knee: New methods using ultrashort TEs
    • Gold GE, Thedens DR, Pauly JM, et al. MR imaging of articular cartilage of the knee: new methods using ultrashort TEs. AJR Am J Roentgenol 1998;170:1223-1226.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 1223-1226
    • Gold, G.E.1    Thedens, D.R.2    Pauly, J.M.3
  • 8
    • 0032860789 scopus 로고    scopus 로고
    • MR imaging of articular cartilage using driven equilibrium
    • Hargreaves BA, Gold GE, Lang PK, et al. MR imaging of articular cartilage using driven equilibrium. Magn Reson Med 1999;42:695-703.
    • (1999) Magn Reson Med , vol.42 , pp. 695-703
    • Hargreaves, B.A.1    Gold, G.E.2    Lang, P.K.3
  • 9
    • 0030090546 scopus 로고    scopus 로고
    • Optimization of a dual echo in the steady state (DESS) Free-precession sequence for imaging cartilage
    • Hardy PA, Recht MP, Piraino D, Thomasson D. Optimization of a dual echo in the steady state (DESS) Free-precession sequence for imaging cartilage. J Magn Reson Imaging 1996;6:329-335.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 329-335
    • Hardy, P.A.1    Recht, M.P.2    Piraino, D.3    Thomasson, D.4
  • 10
    • 0033957730 scopus 로고    scopus 로고
    • Human articular cartilage: Influence of aging and early symptomatic degeneration on the spatial variation of T2-preliminary findings at 3 T
    • Mosher TJ, Dardzinski BJ, Smith MB. Human articular cartilage: influence of aging and early symptomatic degeneration on the spatial variation of T2-preliminary findings at 3 T. Radiology 2000;214:259-266.
    • (2000) Radiology , vol.214 , pp. 259-266
    • Mosher, T.J.1    Dardzinski, B.J.2    Smith, M.B.3
  • 11
    • 0035163230 scopus 로고    scopus 로고
    • Protocol issues for delayed Gd(DTPA)(2-)-enhanced MRI (dGEMRIC) for clinical evaluation of articular cartilage
    • Burstein D, Velyvis J, Scott KT, et al. Protocol issues for delayed Gd(DTPA)(2-)-enhanced MRI (dGEMRIC) for clinical evaluation of articular cartilage. Magn Reson Med 2001;45:36-41.
    • (2001) Magn Reson Med , vol.45 , pp. 36-41
    • Burstein, D.1    Velyvis, J.2    Scott, K.T.3
  • 15
    • 0031866441 scopus 로고    scopus 로고
    • Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging
    • Eckstein F, Schnier M, Haubner M, et al. Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging. Clin Orthop Relat Res 1998;352:137-148.
    • (1998) Clin Orthop Relat Res , vol.352 , pp. 137-148
    • Eckstein, F.1    Schnier, M.2    Haubner, M.3
  • 17
    • 0037306841 scopus 로고    scopus 로고
    • Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation
    • Reeder SB, Pelc NJ, Alley MT, Gold GE. Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation. AJR Am J Roentgenol 2003;180:357-362.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 357-362
    • Reeder, S.B.1    Pelc, N.J.2    Alley, M.T.3    Gold, G.E.4
  • 18
    • 0035009703 scopus 로고    scopus 로고
    • Magnetization preparation during the steady state: Fat-saturated 3D TrueFISP
    • Scheffler K, Heid O, Hennig J. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. Magn Reson Med 2001;45:1075-1080.
    • (2001) Magn Reson Med , vol.45 , pp. 1075-1080
    • Scheffler, K.1    Heid, O.2    Hennig, J.3
  • 19
    • 0031847926 scopus 로고    scopus 로고
    • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain
    • Spielman DM, Adalsteinsson E, Lim KO. Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain. Magn Reson Med 1998;40:376-382.
    • (1998) Magn Reson Med , vol.40 , pp. 376-382
    • Spielman, D.M.1    Adalsteinsson, E.2    Lim, K.O.3
  • 23
    • 0031929722 scopus 로고    scopus 로고
    • In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging
    • Eckstein F, Westhoff J, Sittek H, et al. In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging. AJR Am J Roentgenol 1998;170:593-597.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 593-597
    • Eckstein, F.1    Westhoff, J.2    Sittek, H.3
  • 24
    • 0032796073 scopus 로고    scopus 로고
    • Magnetic resonance imaging of superficial cartilage lesions: Role of contrast in lesion detection
    • Mosher TJ, Pruett SW. Magnetic resonance imaging of superficial cartilage lesions: role of contrast in lesion detection. J Magn Reson Imaging 1999;10:178-182.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 178-182
    • Mosher, T.J.1    Pruett, S.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.