메뉴 건너뛰기




Volumn 2, Issue 4, 2008, Pages 735-738

Insulin delivery route for the artificial pancreas: Subcutaneous, intraperitoneal, or intravenous? Pros and cons

Author keywords

Artificial pancreas; Closed loop control; Insulin delivery

Indexed keywords


EID: 77954067827     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680800200429     Document Type: Conference Paper
Times cited : (48)

References (29)
  • 1
    • 0036902299 scopus 로고    scopus 로고
    • Implantable closed loop glucose-sensing and insulin delivery: The future for insulin pump therapy
    • Renard E. Implantable closed loop glucose-sensing and insulin delivery: the future for insulin pump therapy. Curr Opin Pharmacol. 2002;2(6):708-16.
    • (2002) Curr Opin Pharmacol , vol.2 , Issue.6 , pp. 708-716
    • Renard, E.1
  • 2
    • 34248162815 scopus 로고    scopus 로고
    • The artificial pancreas: How sweet engineering will solve bitter problems
    • Klonoff DC. The artificial pancreas: how sweet engineering will solve bitter problems. J Diabetes Sci Technol. 2007;1(1):72-81.
    • (2007) J Diabetes Sci Technol. , vol.1 , Issue.1 , pp. 72-81
    • Klonoff, D.C.1
  • 4
    • 0017723175 scopus 로고
    • Evaluation of exogenous insulin homeostasis by the artificial pancreas in insulindependent diabetes
    • Mirouze J, Selam JL, Pham TC, Cavadore D. Evaluation of exogenous insulin homeostasis by the artificial pancreas in insulindependent diabetes. Diabetologia. 1977;13(3):273-8.
    • (1977) Diabetologia , vol.13 , Issue.3 , pp. 273-278
    • Mirouze, J.1    Selam, J.L.2    Pham, T.C.3    Cavadore, D.4
  • 5
    • 0025182886 scopus 로고
    • Devices for insulin administration
    • Selam JL, Charles MA. Devices for insulin administration. Diabetes Care. 1990;13(9):955-79.
    • (1990) Diabetes Care , vol.13 , Issue.9 , pp. 955-979
    • Selam, J.L.1    Charles, M.A.2
  • 7
    • 0026659759 scopus 로고
    • Clinical trial of programmable implantable insulin pumps for type 1 diabetes
    • Selam JL, Micossi P, Dunn FL, Nathan DM. Clinical trial of programmable implantable insulin pumps for type 1 diabetes. Diabetes Care. 1992;15(7):877-85.
    • (1992) Diabetes Care , vol.15 , Issue.7 , pp. 877-885
    • Selam, J.L.1    Micossi, P.2    Dunn, F.L.3    Nathan, D.M.4
  • 8
    • 0027972684 scopus 로고
    • [Lys (B28), Pro (B29) ]-human insulin. A rapidly absorbed analogue of human insulin
    • Howey DC, Bowsher RR, Brunelle RL, Woodworth JR. [Lys (B28), Pro (B29) ]-human insulin. A rapidly absorbed analogue of human insulin. Diabetes. 1994;43(3):396-402.
    • (1994) Diabetes , vol.43 , Issue.3 , pp. 396-402
    • Howey, D.C.1    Bowsher, R.R.2    Brunelle, R.L.3    Woodworth, J.R.4
  • 10
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closed-loop systems
    • Hovorka R. Continuous glucose monitoring and closed-loop systems. Diabet Med. 2006;23(1):1-12.
    • (2006) Diabet Med. , vol.23 , Issue.1 , pp. 1-12
    • Hovorka, R.1
  • 11
    • 33845521334 scopus 로고    scopus 로고
    • Feasibility of automating insulin delivery for the treatment of type 1 diabetes
    • Steil GM, Rebrin K, Darwin C, Hariri F, Saad MF. Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes. 2006;55(12):3344-50.
    • (2006) Diabetes , vol.55 , Issue.12 , pp. 3344-3350
    • Steil, G.M.1    Rebrin, K.2    Darwin, C.3    Hariri, F.4    Saad, M.F.5
  • 12
    • 48649083317 scopus 로고    scopus 로고
    • Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
    • Epub 2008 Feb. 5
    • Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane W V. Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care. 2008;31(5):934-9. Epub 2008 Feb. 5.
    • (2008) Diabetes Care , vol.31 , Issue.5 , pp. 934-939
    • Weinzimer, S.A.1    Steil, G.M.2    Swan, K.L.3    Dziura, J.4    Kurtz, N.5    Tamborlane, W.V.6
  • 13
    • 1642452596 scopus 로고    scopus 로고
    • Closed-loop insulin deliverythe path to physiological glucose control
    • Steil GM, Panteleon AE, Rebrin K. Closed-loop insulin deliverythe path to physiological glucose control. Adv Drug Deliv Rev. 2004;56(2):125-44.
    • (2004) Adv Drug Deliv Rev. , vol.56 , Issue.2 , pp. 125-144
    • Steil, G.M.1    Panteleon, A.E.2    Rebrin, K.3
  • 14
    • 33845340831 scopus 로고    scopus 로고
    • OmniPod insulin management system: Patient perceptions, preference, and glycemic control
    • Zisser H, Jovanovic L. OmniPod insulin management system: patient perceptions, preference, and glycemic control. Diabetes Care. 2006;29(9):2175.
    • (2006) Diabetes Care , vol.29 , Issue.9 , pp. 2175
    • Zisser, H.1    Jovanovic, L.2
  • 15
    • 0017122578 scopus 로고
    • Comparison of peripheral and portal routes of insulin infusion by a computercontrolled insulin infusion system (artificial endocrine pancreas)
    • Botz CK, Leibel BS, Zingg W, Gander RE, Albisser AM. Comparison of peripheral and portal routes of insulin infusion by a computercontrolled insulin infusion system (artificial endocrine pancreas). Diabetes. 1976;25(8):691-700.
    • (1976) Diabetes , vol.25 , Issue.8 , pp. 691-700
    • Botz, C.K.1    Leibel, B.S.2    Zingg, W.3    Gander, R.E.4    Albisser, A.M.5
  • 17
    • 0030007999 scopus 로고    scopus 로고
    • Postprandial insulin profiles with implantable pump therapy may explain decreased frequency of severe hypoglycemia, compared with intensive subcutaneous regimens, in insulin-dependent diabetes mellitus patients
    • Nathan DM, Dunn FL, Bruch J, McKitrick C, Larkin M, Haggan C, Lavin-Tompkins J, Norman D, Rogers D, Simon D. Postprandial insulin profiles with implantable pump therapy may explain decreased frequency of severe hypoglycemia, compared with intensive subcutaneous regimens, in insulin-dependent diabetes mellitus patients. Am J Med. 1996;100(4):412-7.
    • (1996) Am J Med. , vol.100 , Issue.4 , pp. 412-417
    • Nathan, D.M.1    Dunn, F.L.2    Bruch, J.3    McKitrick, C.4    Larkin, M.5    Haggan, C.6    Lavin-Tompkins, J.7    Norman, D.8    Rogers, D.9    Simon, D.10
  • 19
    • 0028918227 scopus 로고
    • Feasibility of intraperitoneal insulin therapy with programmable implantable pumps in IDDM. A multicenter study. The EVADIAC Study Group
    • Hanaire-Broutin H, Broussolle C, Jeandidier N, Renard E, Guerci B, Haardt MJ, Lassmann-Vague V. Feasibility of intraperitoneal insulin therapy with programmable implantable pumps in IDDM. A multicenter study. The EVADIAC Study Group. Diabetes Care. 1995;18(3):388-92.
    • (1995) Diabetes Care , vol.18 , Issue.3 , pp. 388-392
    • Hanaire-Broutin, H.1    Broussolle, C.2    Jeandidier, N.3    Renard, E.4    Guerci, B.5    Haardt, M.J.6    Lassmann-Vague, V.7
  • 20
    • 0036241609 scopus 로고    scopus 로고
    • Comparison of blood glucose stability and HbA1c between implantable insulin pumps using U400 HOE 21PH insulin and external pumps using lispro in type 1 diabetic patients: A pilot study
    • the EVADIAC Study Group
    • Catargi B, Meyer L, Melki V, Renard E, Jeandidier N; for the EVADIAC Study Group. Comparison of blood glucose stability and HbA1c between implantable insulin pumps using U400 HOE 21PH insulin and external pumps using lispro in type 1 diabetic patients: a pilot study. Diabetes Metab. 2002;28(2):133-7.
    • (2002) Diabetes Metab. , vol.28 , Issue.2 , pp. 133-137
    • Catargi, B.1    Meyer, L.2    Melki, V.3    Renard, E.4    Jeandidier, N.5
  • 21
    • 0027955099 scopus 로고
    • French multicentre experience with implantable insulin pumps. The EVADIAC Study Group
    • Broussolle C, Jeandidier N, Hanaire-Broutin H. French multicentre experience with implantable insulin pumps. The EVADIAC Study Group. Lancet. 1994;343(8896):514-5.
    • (1994) Lancet , vol.343 , Issue.8896 , pp. 514-515
    • Broussolle, C.1    Jeandidier, N.2    Hanaire-Broutin, H.3
  • 23
    • 0034025842 scopus 로고    scopus 로고
    • Continuous intraperitoneal insulin infusion partly restores the glucagon response to hypoglycemia in type 1 diabetic patients
    • Oskarsson PR, Lins PE, Backman L, Adamson UC. Continuous intraperitoneal insulin infusion partly restores the glucagon response to hypoglycemia in type 1 diabetic patients. Diabetes Metab. 2000;26(2):118-24.
    • (2000) Diabetes Metab. , vol.26 , Issue.2 , pp. 118-124
    • Oskarsson, P.R.1    Lins, P.E.2    Backman, L.3    Adamson, U.C.4
  • 24
    • 0033430388 scopus 로고    scopus 로고
    • Metabolic and hormonal responses to exercise in type 1 diabetic patients during continuous subcutaneous, as compared to continuous intraperitoneal, insulin infusion
    • Oskarsson PR, Lins PE, Wallberg-Henriksson H, Adamson UC. Metabolic and hormonal responses to exercise in type 1 diabetic patients during continuous subcutaneous, as compared to continuous intraperitoneal, insulin infusion. Diabetes Metab. 1999;25(6):491-7.
    • (1999) Diabetes Metab. , vol.25 , Issue.6 , pp. 491-497
    • Oskarsson, P.R.1    Lins, P.E.2    Wallberg-Henriksson, H.3    Adamson, U.C.4
  • 26
    • 0026787245 scopus 로고
    • Comparison of peripheral and portal (via the umbilical vein) routes of insulin infusion in IDDM patients
    • Shishko PI, Kovalev PA, Goncharov VG, Zajarny IU. Comparison of peripheral and portal (via the umbilical vein) routes of insulin infusion in IDDM patients. Diabetes. 1982;41(9):1042-9.
    • (1982) Diabetes , vol.41 , Issue.9 , pp. 1042-1049
    • Shishko, P.I.1    Kovalev, P.A.2    Goncharov, V.G.3    Zajarny, I.U.4
  • 27
    • 33751506973 scopus 로고    scopus 로고
    • Artificial beta cell: Clinical experience toward an implantable closed-loop insulin delivery system
    • Renard E, Costalat G, Chevassus H, Bringer J. Artificial beta cell: clinical experience toward an implantable closed-loop insulin delivery system. Diabetes Metab. 2006;32(5 Pt 2):497-502.
    • (2006) Diabetes Metab. , vol.32 , Issue.5 PART 2 , pp. 497-502
    • Renard, E.1    Costalat, G.2    Chevassus, H.3    Bringer, J.4
  • 28
    • 33845497506 scopus 로고    scopus 로고
    • Closed loop insulin delivery using implanted insulin pumps and sensors in type 1 diabetic patients
    • Renard E, Costalat G, Chevassus H, Bringer J. Closed loop insulin delivery using implanted insulin pumps and sensors in type 1 diabetic patients. Diabetes Res Clin Pract. 2006;74(Suppl 2):S173-7.
    • (2006) Diabetes Res Clin Pract. , vol.74 , Issue.SUPPL. 2
    • Renard, E.1    Costalat, G.2    Chevassus, H.3    Bringer, J.4
  • 29
    • 0027958298 scopus 로고
    • Insulin antibody responses after long-term intraperitoneal insulin administration via implantable programmable insulin delivery systems
    • Olsen CL, Chan E, Turner DS, Iravani M, Nagy M, Selam JL, Wong ND, Waxman K, Charles MA. Insulin antibody responses after long-term intraperitoneal insulin administration via implantable programmable insulin delivery systems. Diabetes Care. 1994;17(3):169-76.
    • (1994) Diabetes Care , vol.17 , Issue.3 , pp. 169-176
    • Olsen, C.L.1    Chan, E.2    Turner, D.S.3    Iravani, M.4    Nagy, M.5    Selam, J.L.6    Wong, N.D.7    Waxman, K.8    Charles, M.A.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.