메뉴 건너뛰기




Volumn , Issue , 2009, Pages 411-425

MRI Compatible Device for Robotic Assisted Interventions to Prostate Cancer

Author keywords

Bistable module concept; Dielectric elastomer actuators (DEAs); Magnetic position sensor; Magnetic resonance imaging (MRI); Manipulator precision; MRI compatible device for robotic assisted interventions to prostate cancer; Prostate cancer therapy; Radical prostatectomy; Transperineal prostate cancer needle biopsy

Indexed keywords


EID: 77953518004     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9780470744697.ch22     Document Type: Chapter
Times cited : (7)

References (25)
  • 1
    • 9244239759 scopus 로고    scopus 로고
    • Future perspectives for intraoperative MRI
    • Jolesz, F. (2005) Future perspectives for intraoperative MRI, Neurosurgery Clinics of North America, 16, 201-13.
    • (2005) Neurosurgery Clinics of North America , vol.16 , pp. 201-213
    • Jolesz, F.1
  • 2
    • 84957057529 scopus 로고    scopus 로고
    • MR Compatibility of Mechatronic Devices: Design Criteria, Medical Image Computing and Computer-Assisted Intervention
    • Chinzei, K., Kikinis, R. and Jolesz, F. (1999) MR Compatibility of Mechatronic Devices: Design Criteria, Medical Image Computing and Computer-Assisted Intervention, 1020-30.
    • (1999) , pp. 1020-1030
    • Chinzei, K.1    Kikinis, R.2    Jolesz, F.3
  • 3
    • 3042632335 scopus 로고    scopus 로고
    • Manipulation in MRI Devices Using Electrostrictive Polymer Actuators: with an Application to Reconfigurable Imaging Coils
    • , New Orleans, LA, 23 April-2 May
    • Vogan, J., Wingert, A., Hafez, M., et al. (2004) Manipulation in MRI Devices Using Electrostrictive Polymer Actuators: with an Application to Reconfigurable Imaging Coils, Proceedings of the 2004 IEEE International Conference on Robotics and Automation, New Orleans, LA, 23 April-2 May, 2498-504.
    • (2004) Proceedings of the 2004 IEEE International Conference on Robotics and Automation , pp. 2498-2504
    • Vogan, J.1    Wingert, A.2    Hafez, M.3
  • 4
    • 33750341596 scopus 로고    scopus 로고
    • Large-Scale Failure Modes of Dielectric Elastomer Actuators
    • Plante, J.S. and Dubowsky, S. (2006) Large-Scale Failure Modes of Dielectric Elastomer Actuators, Int. J. Solids and Structures, 43, 7727-51.
    • (2006) Int. J. Solids and Structures , vol.43 , pp. 7727-7751
    • Plante, J.S.1    Dubowsky, S.2
  • 8
    • 45349096041 scopus 로고    scopus 로고
    • Cancer Facts and Figures 2007
    • American Cancer Society
    • Jemal, A. et al. (2007) Cancer Facts and Figures 2007, American Cancer Society.
    • (2007)
    • Jemal, A.1
  • 9
    • 79960750571 scopus 로고    scopus 로고
    • NCCN Clinical Practice Guidelines in Oncology: Prostate Cancer Early Detection, VI
    • available online from the National Comprehensive Ccancer Network
    • Babaian, R.J. et al., NCCN Clinical Practice Guidelines in Oncology: Prostate Cancer Early Detection, VI, available online from the National Comprehensive Ccancer Network www.nccn.org, 2006.
    • (2006)
    • Babaian, R.J.1
  • 10
    • 0030970742 scopus 로고    scopus 로고
    • Clinical significance of repeat sextant biopsies in prostate cancer patients
    • Stoumbakis, N., Cookson, M.S., Reuter, V.E. and Fair, W.R. (1997) Clinical significance of repeat sextant biopsies in prostate cancer patients, Urology, 49 (3A SUPPL), 113-8.
    • (1997) Urology , vol.49 , Issue.3 A SUPPL , pp. 113-118
    • Stoumbakis, N.1    Cookson, M.S.2    Reuter, V.E.3    Fair, W.R.4
  • 11
    • 0029671182 scopus 로고    scopus 로고
    • Small (S3-cm) Renal Masses: Detection with CT versus US and Pathologic Correlation
    • Jamis-Dow, C.A., Choyke, P.L., Jennings, S.B., et al. (1996) Small (S3-cm) Renal Masses: Detection with CT versus US and Pathologic Correlation, Genitourinary Radiology, 198 (3), 785-8.
    • (1996) Genitourinary Radiology , vol.198 , Issue.3 , pp. 785-788
    • Jamis-Dow, C.A.1    Choyke, P.L.2    Jennings, S.B.3
  • 12
    • 0036074112 scopus 로고    scopus 로고
    • Real time MRI-ultrasound image guided stereotactic prostate biopsy
    • Kaplan, I., Oldenburg, N.E., Meskell, P., et al. (2002) Real time MRI-ultrasound image guided stereotactic prostate biopsy, Magnetic Resonance Imaging, 20, 295-299.
    • (2002) Magnetic Resonance Imaging , vol.20 , pp. 295-299
    • Kaplan, I.1    Oldenburg, N.E.2    Meskell, P.3
  • 13
    • 0036494034 scopus 로고    scopus 로고
    • Improved Magnetic Resonance Imaging Detection of Prostate Cancer in a Transgenic Mouse Model
    • Song, S.K., Qu, Z., Garabedian, E.M., Gordon, J.I., Milbrant, J. and Ackerman, J.J.H. (2002) Improved Magnetic Resonance Imaging Detection of Prostate Cancer in a Transgenic Mouse Model, Cancer Research, 62, 1555-8.
    • (2002) Cancer Research , vol.62 , pp. 1555-1558
    • Song, S.K.1    Qu, Z.2    Garabedian, E.M.3    Gordon, J.I.4    Milbrant, J.5    Ackerman, J.J.H.6
  • 14
    • 1642406172 scopus 로고    scopus 로고
    • Endorectal Magnetic Resonance Imaging and Spectroscopy for the Detection of Tumor Foci in Men with Prior Negative Transrectal Ultrasound Prostate Biopsy
    • Yuen, J.S.P., Thng, C.H., Tan, P.H., et al. (2004) Endorectal Magnetic Resonance Imaging and Spectroscopy for the Detection of Tumor Foci in Men with Prior Negative Transrectal Ultrasound Prostate Biopsy, J. Urology, 171, 1482-68.
    • (2004) J. Urology , vol.171 , pp. 1482-1468
    • Yuen, J.S.P.1    Thng, C.H.2    Tan, P.H.3
  • 15
    • 0033047030 scopus 로고    scopus 로고
    • American Brachytherapy Society (ABS) Recommendations for Transperineal Permanent Brachytherapy of Prostate Cancer
    • Nag, S., Beyer, D., Friedland, J., et al. (1999) American Brachytherapy Society (ABS) Recommendations for Transperineal Permanent Brachytherapy of Prostate Cancer, Int. J. Radiation Oncology Bio. Phys, 44 (4), 789-99.
    • (1999) Int. J. Radiation Oncology Bio. Phys , vol.44 , Issue.4 , pp. 789-799
    • Nag, S.1    Beyer, D.2    Friedland, J.3
  • 16
    • 20344396112 scopus 로고    scopus 로고
    • Precise Evaluation of Positioning Repeatability of MR-Compatible Manipulator Inside MRI, Medical Image Computing and Computer-Assisted Intervention
    • Saint-Malo, France, 26-30 September 2004
    • Koseki, Y., Kikinis, R., Jolesz, F. and Chinzei, K., (2004) Precise Evaluation of Positioning Repeatability of MR-Compatible Manipulator Inside MRI, Medical Image Computing and Computer-Assisted Intervention, Saint-Malo, France, 26-30 September 2004, 192-9.
    • (2004) , pp. 192-199
    • Koseki, Y.1    Kikinis, R.2    Jolesz, F.3    Chinzei, K.4
  • 17
    • 0345307715 scopus 로고    scopus 로고
    • Remote Actuation Mechanism for MR-compatible Manipulator Using Leverage and Parallelogram IEEE International Conference on Robotics and Automation
    • Taipei, Taiwan, 12-17 May 2003
    • Koseki, Y., Koyachi, N., Arai, T. and Chinzei, K. (2003) Remote Actuation Mechanism for MR-compatible Manipulator Using Leverage and Parallelogram IEEE International Conference on Robotics and Automation, Taipei, Taiwan, 12-17 May 2003, 652-7.
    • (2003) , pp. 652-657
    • Koseki, Y.1    Koyachi, N.2    Arai, T.3    Chinzei, K.4
  • 18
    • 84890645531 scopus 로고    scopus 로고
    • Brigham and Women's Hospital
    • Private Communications
    • Roebuck, J. PhD, MD, Brigham and Women's Hospital, Private Communications, 2005-2007.
    • Roebuck, J.1
  • 19
    • 0034093188 scopus 로고    scopus 로고
    • The effects of the use of piezoelectric motors in a 1.5-Tesla high-field magnetic resonance imaging system (MRI)
    • Wendt, O., Oellinger, J., Luth, T.C., et al. (2000) The effects of the use of piezoelectric motors in a 1.5-Tesla high-field magnetic resonance imaging system (MRI), Biomed Tech, 45, 20-5.
    • (2000) Biomed Tech , vol.45 , pp. 20-25
    • Wendt, O.1    Oellinger, J.2    Luth, T.C.3
  • 20
    • 84890688719 scopus 로고    scopus 로고
    • A SytemforMRI-guided Prostate Interventions Proceedings of the International Conference on Biomedical Robotics and Biomechatronics
    • Pisa, Italy, 20-22 Febuary 2006
    • DiMaio, S.P., Fisher, G.S., Haker, S.J., et al. (2006) A SytemforMRI-guided Prostate Interventions Proceedings of the International Conference on Biomedical Robotics and Biomechatronics, Pisa, Italy, 20-22 Febuary 2006, 68-73.
    • (2006) , pp. 68-73
    • DiMaio, S.P.1    Fisher, G.S.2    Haker, S.J.3
  • 21
    • 20344400620 scopus 로고    scopus 로고
    • CT and MR Compatible Light Puncture Robot: Architectural Design and First Experiment
    • Medical Image Computing and Computer- Assisted Intervention, Saint-Malo, France, 26-30 September 2004
    • Taillant, E., Avila-Vilchis, J.C., Allegrini, C., et al. CT and MR Compatible Light Puncture Robot: Architectural Design and First Experiment, Medical Image Computing and Computer- Assisted Intervention, Saint-Malo, France, 26-30 September 2004, 145-52, 2004.
    • (2004) , pp. 145-152
    • Taillant, E.1    Avila-Vilchis, J.C.2    Allegrini, C.3
  • 23
    • 20044383186 scopus 로고    scopus 로고
    • Bouquet brachytherapy: Feasibility and optimization of conically spaced implants
    • Fu, L., Ng, W.S., Liu, H., et al. (2005) Bouquet brachytherapy: Feasibility and optimization of conically spaced implants, Am. Brachytherapy Soc., 4, 59-63.
    • (2005) Am. Brachytherapy Soc. , vol.4 , pp. 59-63
    • Fu, L.1    Ng, W.S.2    Liu, H.3
  • 24
    • 51649124475 scopus 로고    scopus 로고
    • An MRI Compatible Manipulator for Prostate Cancer Detection and Treatment, M.S. Thesis
    • Massachusetts Institute of Technology
    • Devita, L.M., An MRI Compatible Manipulator for Prostate Cancer Detection and Treatment, M.S. Thesis, Massachusetts Institute of Technology, 2007.
    • (2007)
    • Devita, L.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.