Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy

Author keywords

EDR2; GafChromic EBT; IMRT; Monte Carlo; Quality assurance

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DOSIMETRY; IONIZATION CHAMBERS; PHOTOIONIZATION; PHOTONS; QUALITY ASSURANCE; RADIOTHERAPY;

EID: 77953508729     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3395574     Document Type: Article
Times cited : (14)

References (31)
  • 1
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee
    • DOI 10.1118/1.1591194
    • G. A. Ezzell, J. M. Galvin, D. Low, J. R. Palta, I. Rosen, M. B. Sharpe, P. Xia, Y. Xiao, L. Xing, and C. X. Yu, " Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee.," Med. Phys. MPHYA6 0094-2405 30, 2089-2115 (2003). 10.1118/1.1591194 (Pubitemid 37022015)
    • (2003) Medical Physics , vol.30 , Issue.8 , pp. 2089-2115
    • Ezzell, G.A.1    Galvin, J.M.2    Low, D.3    Palta, J.R.4    Rosen, I.5    Sharpe, M.B.6    Xia, P.7    Xiao, Y.8    Xing, L.9    Yu, C.X.10
  • 2
    • 0032798513 scopus 로고    scopus 로고
    • Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity- modulated radiation therapy
    • DOI 10.1118/1.598650
    • D. A. Low, J. F. Dempsey, R. Venkatesan, S. Mutic, J. Markman, E. Mark Haacke, and J. A. Purdy, " Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity modulated radiation therapy.," Med. Phys. MPHYA6 0094-2405 26, 1542-1551 (1999). 10.1118/1.598650 (Pubitemid 29402265)
    • (1999) Medical Physics , vol.26 , Issue.8 , pp. 1542-1551
    • Low, D.A.1    Dempsey, J.F.2    Venkatesan, R.3    Mutic, S.4    Markman, J.5    Haacke, E.M.6    Purdy, J.A.7
  • 3
    • 0037732932 scopus 로고    scopus 로고
    • MAGIC-type polymer gel for three-dimensional dosimetry: Intensity-modulated radiation therapy verification
    • DOI 10.1118/1.1576392
    • H. Gustavsson, A. Karlsson, S. A. Back, L. E. Olsson, P. Haraldsson, P. Engstrom, and H. Nystrom, " MAGIC-type polymer gel for three-dimensional dosimetry: Intensity modulated radiation therapy verification.," Med. Phys. MPHYA6 0094-2405 30, 1264-1271 (2003). 10.1118/1.1576392 (Pubitemid 36740494)
    • (2003) Medical Physics , vol.30 , Issue.6 , pp. 1264-1271
    • Gustavsson, H.1    Karlsson, A.2    Back, S.A.J.3    Olsson, L.E.4    Haraldsson, P.5    Engstrom, P.6    Nystrom, H.7
  • 4
    • 22244450090 scopus 로고    scopus 로고
    • Characterization of a 2D ion chamber array for the verification of radiotherapy treatments
    • DOI 10.1088/0031-9155/50/14/012
    • E. Spezi, A. L. Angelini, F. Romani, and A. Ferri, " Characterization of a 2D ion chamber array for the verification of radiotherapy treatments.," Phys. Med. Biol. PHMBA7 0031-9155 50, 3361-3373 (2005). 10.1088/0031-9155/50/14/012 (Pubitemid 40991695)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.14 , pp. 3361-3373
    • Spezi, E.1    Angelini, A.L.2    Romani, F.3    Ferri, A.4
  • 5
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • DOI 10.1118/1.1567831
    • P. A. Jursinic and B. E. Nelms, " A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery.," Med. Phys. MPHYA6 0094-2405 30, 870-879 (2003). 10.1118/1.1567831 (Pubitemid 36578690)
    • (2003) Medical Physics , vol.30 , Issue.5 , pp. 870-879
    • Jursinic, P.A.1    Nelms, B.E.2
  • 6
    • 0030962169 scopus 로고    scopus 로고
    • A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering
    • DOI 10.1118/1.597999
    • S. E. Burch, K. J. Kearfott, J. H. Trueblood, W. C. Sheils, J. I. Yeo, and C. K. Wang, " A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering.," Med. Phys. MPHYA6 0094-2405 24, 775-783 (1997). 10.1118/1.597999 (Pubitemid 27215216)
    • (1997) Medical Physics , vol.24 , Issue.5 , pp. 775-783
    • Burch, S.E.1    Kearfott, K.J.2    Trueblood, J.H.3    Sheils, W.C.4    Yeo, J.I.5    Wang, C.K.C.6
  • 7
    • 0036127078 scopus 로고    scopus 로고
    • Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation
    • DOI 10.1118/1.1449493
    • S. G. Ju, Y. C. Ahn, S. J. Huh, and I. J. Yeo, " Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation.," Med. Phys. MPHYA6 0094-2405 29, 351-355 (2002). 10.1118/1.1449493 (Pubitemid 34241157)
    • (2002) Medical Physics , vol.29 , Issue.3 , pp. 351-355
    • Ju, S.G.1    Ahn, Y.C.2    Huh, S.J.3    Yeo, I.J.4
  • 8
    • 1642495624 scopus 로고    scopus 로고
    • Verification of IMRT fields by film dosimetry
    • DOI 10.1118/1.1631093
    • M. Bucciolini, F. B. Buonamici, and M. Casati, " Verification of IMRT fields by film dosimetry.," Med. Phys. MPHYA6 0094-2405 31, 161-168 (2004). 10.1118/1.1631093 (Pubitemid 38113877)
    • (2004) Medical Physics , vol.31 , Issue.1 , pp. 161-168
    • Bucciolini, M.1    Buonamici, F.B.2    Casati, M.3
  • 9
    • 3142727652 scopus 로고    scopus 로고
    • EDR2 film dosimetry for IMRT verification using low-energy photon filters
    • DOI 10.1118/1.1760190
    • I. J. Yeo, A. Beiki-Ardakani, Y. B. Cho, M. Heydarian, T. Zhang, and M. Islam, " EDR2 film dosimetry for IMRT verification using low-energy photon filters.," Med. Phys. MPHYA6 0094-2405 31, 1960-1963 (2004). 10.1118/1.1760190 (Pubitemid 38924814)
    • (2004) Medical Physics , vol.31 , Issue.7 , pp. 1960-1963
    • Yeo, I.J.1    Beiki-Ardakani, A.2    Cho, Y.-B.3    Heydarian, M.4    Zhang, T.5    Islam, M.6
  • 10
    • 33646461862 scopus 로고    scopus 로고
    • Evaluation of GafChromic EBT prototype B for external beam dose verification
    • MPHYA6 0094-2405. 10.1118/1.2188077
    • M. Todorovic, M. Fischer, F. Cremers, E. Thom, and R. Schmidt, " Evaluation of GafChromic EBT prototype B for external beam dose verification.," Med. Phys. MPHYA6 0094-2405 33 1321-1328 (2006). 10.1118/1.2188077
    • (2006) Med. Phys. , vol.33 , pp. 1321-1328
    • Todorovic, M.1    Fischer, M.2    Cremers, F.3    Thom, E.4    Schmidt, R.5
  • 11
    • 34547253812 scopus 로고    scopus 로고
    • Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance
    • DOI 10.1088/0031-9155/52/14/013, PII S0031915507435813, 013
    • M. Fuss, E. Sturtewagen, C. De Wagter, and D. Georg, " Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.," Phys. Med. Biol. PHMBA7 0031-9155 52, 4211-4225 (2007). 10.1088/0031-9155/52/14/013 (Pubitemid 47134635)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.14 , pp. 4211-4225
    • Fuss, M.1    Sturtewagen, E.2    De Wagter, C.3    Georg, D.4
  • 12
    • 33845329557 scopus 로고    scopus 로고
    • Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC® film
    • DOI 10.1118/1.2370505, 012612MPH
    • B. D. Lynch, J. Kozelka, M. K. Ranade, J. G. Li, W. E. Simon, and J. F. Dempsey, " Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.," Med. Phys. MPHYA6 0094-2405 33, 4551-4556 (2006). 10.1118/1.2370505 (Pubitemid 44868091)
    • (2006) Medical Physics , vol.33 , Issue.12 , pp. 4551-4556
    • Lynch, B.D.1    Kozelka, J.2    Ranade, M.K.3    Li, J.G.4    Simon, W.E.5    Dempsey, J.F.6
  • 13
    • 46149100990 scopus 로고    scopus 로고
    • GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis
    • DOI 10.1118/1.2938522
    • S. Saur and J. Frengen, " GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis.," Med. Phys. MPHYA6 0094-2405 35, 3094-3101 (2008). 10.1118/1.2938522 (Pubitemid 351904513)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3094-3101
    • Saur, S.1    Frengen, J.2
  • 14
    • 46149099592 scopus 로고    scopus 로고
    • Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure
    • DOI 10.1118/1.2936334
    • L. Menegotti, A. Delana, and A. Martignano, " Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure.," Med. Phys. MPHYA6 0094-2405 35, 3078-3085 (2008). 10.1118/1.2936334 (Pubitemid 351904511)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3078-3085
    • Menegotti, L.1    Delana, A.2    Martignano, A.3
  • 15
    • 34247503351 scopus 로고    scopus 로고
    • Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry
    • DOI 10.1088/0031-9155/52/1/015, PII S003191550724850X, 015
    • L. Paelinck, W. De Neve, and C. De Wagter, " Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.," Phys. Med. Biol. PHMBA7 0031-9155 52, 231-242 (2007). 10.1088/0031-9155/52/1/015 (Pubitemid 46646276)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.1 , pp. 231-242
    • Paelinck, L.1    De Neve, W.2    De Wagter, C.3
  • 16
    • 22544440841 scopus 로고    scopus 로고
    • Precise radiochromic film dosimetry using a flat-bed document scanner
    • DOI 10.1118/1.1929253
    • S. Devic, J. Seuntjens, E. Sham, E. B. Podgorsak, C. R. Schmidtlein, A. S. Kirov, and C. G. Soares, " Precise radiochromic film dosimetry using a flat-bed document scanner.," Med. Phys. MPHYA6 0094-2405 32, 2245-2253 (2005). 10.1118/1.1929253 (Pubitemid 41023182)
    • (2005) Medical Physics , vol.32 , Issue.7 , pp. 2245-2253
    • Devic, S.1    Seuntjens, J.2    Sham, E.3    Podgorsak, E.B.4    Schmidtlein, C.R.5    Kirov, A.S.6    Soares, C.G.7
  • 17
    • 33750510893 scopus 로고    scopus 로고
    • Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification
    • DOI 10.1016/j.meddos.2006.06.001, PII S0958394706001269
    • A. Sankar, K. M. Ayyangar, R. M. Nehru, P. G. Kurup, V. Murali, C. A. Enke, and J. Velmurugan, " Comparison of Kodak EDR2 and Gafchromic EBT film for intensity modulated radiation therapy dose distribution verification.," Med. Dosim. ZZZZZZ 0739-0211 31, 273-282 (2006). 10.1016/j.meddos.2006.06.001 (Pubitemid 44667461)
    • (2006) Medical Dosimetry , vol.31 , Issue.4 , pp. 273-282
    • Sankar, A.1    Ayyangar, K.M.2    Nehru, R.M.3    Gopalakrishna Kurup, P.G.4    Murali, V.5    Enke, C.A.6    Velmurugan, J.7
  • 18
    • 58149269273 scopus 로고    scopus 로고
    • Analysis of uncertainties in Gafchromic EBT film dosimetry of photon beams
    • PHMBA7 0031-9155,. 10.1088/0031-9155/53/24/001
    • M. Martišíková, B. Ackermann, and O. Jakel, " Analysis of uncertainties in Gafchromic EBT film dosimetry of photon beams.," Phys. Med. Biol. PHMBA7 0031-9155 53, 7013-7027 (2008). 10.1088/0031-9155/53/24/001
    • (2008) Phys. Med. Biol. , vol.53 , pp. 7013-7027
    • Martišíková, M.1    Ackermann, B.2    Jakel, O.3
  • 19
    • 14644419015 scopus 로고    scopus 로고
    • Dosimetric accuracy of Kodak EDR2 film for IMRT verifications
    • DOI 10.1118/1.1852791
    • N. Childress, M. Salehpour, L. Dong, C. Bloch, R. Allen White, and I. Rosen, " Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.," Med. Phys. MPHYA6 0094-2405 32, 539-548 (2005). 10.1118/1.1852791 (Pubitemid 40322335)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 539-548
    • Childress, N.L.1    Salehpour, M.2    Dong, L.3    Bloch, C.4    White, R.A.5    Rosen, I.I.6
  • 21
    • 27844610290 scopus 로고    scopus 로고
    • Development of a parallel electron and photon transport code (PMCEPT) I: Method and absorbed dose computation in water
    • KPSJAS 0374-4884.
    • O. Kum and S. Lee, " Development of a parallel electron and photon transport code (PMCEPT) I: Method and absorbed dose computation in water.," J. Korean Phys. Soc. KPSJAS 0374-4884 47, 716-725 (2005).
    • (2005) J. Korean Phys. Soc. , vol.47 , pp. 716-725
    • Kum, O.1    Lee, S.2
  • 22
    • 33751037893 scopus 로고    scopus 로고
    • Development of a parallel electron and photon transport (PMCEPT) Code II: Absorbed dose computation in homogeneous and heterogeneous media
    • KPSJAS 0374-4884.
    • H. Kim and O. Kum, " Development of a parallel electron and photon transport (PMCEPT) Code II: Absorbed dose computation in homogeneous and heterogeneous media.," J. Korean Phys. Soc. KPSJAS 0374-4884 49, 1640-1651 (2007).
    • (2007) J. Korean Phys. Soc. , vol.49 , pp. 1640-1651
    • Kim, H.1    Kum, O.2
  • 23
    • 0003682469 scopus 로고
    • International Commission on Radiation Units and Measurements (ICRU), "," ICRU Report No. 44 (ICRU 465 Publications, Bethesda, Maryland).
    • International Commission on Radiation Units and Measurements (ICRU), " Tissue Substitutes in Radiation. Dosimetry and Measurements.," ICRU Report No. 44 (ICRU 465 Publications, Bethesda, Maryland, 1989).
    • (1989) Tissue Substitutes in Radiation. Dosimetry and Measurements
  • 24
    • 85027220098 scopus 로고    scopus 로고
    • Personal communication with, Virginia Commonwealth University, USA (Department of Radiation Oncology, 401 College Street, P.O. Box 980058, Richmond, Virginia).
    • Personal communication with J. Siebers, Virginia Commonwealth University, USA (Department of Radiation Oncology, 401 College Street, P.O. Box 980058, Richmond, Virginia).
    • Siebers, J.1
  • 25
    • 44449122864 scopus 로고    scopus 로고
    • Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife
    • DOI 10.1118/1.2912179
    • E. E. Wilcox and G. M. Daskalov, " Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife.," Med. Phys. MPHYA6 0094-2405 35, 2259-2266 (2008). 10.1118/1.2912179 (Pubitemid 351752943)
    • (2008) Medical Physics , vol.35 , Issue.6 , pp. 2259-2266
    • Wilcox, E.E.1    Daskalov, G.M.2
  • 26
    • 0037035943 scopus 로고    scopus 로고
    • Investigation of photon beam output factors for conformal radiation therapy - Monte Carlo simulations and measurements
    • DOI 10.1088/0031-9155/47/11/401, PII S0031915502323959
    • F. Haryanto, M. Fippel, W. Laub, O. Dohm, and F. Nusslin, " Investigation of photon beam output factors for conformal radiation therapy-Monte Carlo simulations and measurements.," Phys. Med. Biol. PHMBA7 0031-9155 47, N133-N143 (2002). 10.1088/0031-9155/47/11/401 (Pubitemid 34662209)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.11
    • Haryanto, F.1    Fippel, M.2    Laub, W.3    Dohm, O.4    Nusslin, F.5
  • 27
    • 38849151519 scopus 로고    scopus 로고
    • Total scatter factors of small beams: A multidetector and Monte Carlo study
    • DOI 10.1118/1.2828195
    • P. Francescon, S. Cora, and C. Cavedon, " Total scatter factors of small beams: A 475 multidetector and Monte Carlo study.," Med. Phys. MPHYA6 0094-2405 35, 504-513 (2008). 10.1118/1.2828195 (Pubitemid 351190870)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 504-513
    • Francescon, P.1    Cora, S.2    Cavedon, C.3
  • 28
    • 37549052531 scopus 로고    scopus 로고
    • Small fields: Nonequilibrium radiation dosimetry
    • MPHYA6 0094-2405,. 10.1118/1.2815356
    • I. J. Das, G. X. Ding, and A. Ahnesjo, " Small fields: Nonequilibrium radiation dosimetry.," Med. Phys. MPHYA6 0094-2405 35, 206-215 (2008). 10.1118/1.2815356
    • (2008) Med. Phys. , vol.35 , pp. 206-215
    • Das, I.J.1    Ding, G.X.2    Ahnesjo, A.3
  • 29
    • 34447321620 scopus 로고    scopus 로고
    • Evaluation of GAFCHROMIC® EBT film for CyberKnife® dosimetry
    • DOI 10.1118/1.2734384
    • E. E. Wilcox and G. M. Daskalov, " Evaluation of GAFCHROMIC EBT film for Cyberknife dosimetry.," Med. Phys. MPHYA6 0094-2405 34, 1967-1974 (2007). 10.1118/1.2734384 (Pubitemid 47055731)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 1967-1974
    • Wilcox, E.E.1    Daskalov, G.M.2
  • 30
    • 65449139869 scopus 로고    scopus 로고
    • Monte Carlo evaluation of the convolution/superposition algorithm of Hi-Art tomotherapy in heterogeneous phantoms and clinical cases
    • MPHYA6 0094-2405,. 10.1118/1.3112364
    • E. Sterpin, F. Salvat, G. Olivera, and S. Vynckier, " Monte Carlo evaluation of the convolution/superposition algorithm of Hi-Art tomotherapy in heterogeneous phantoms and clinical cases.," Med. Phys. MPHYA6 0094-2405 36, 1566-1575 (2009). 10.1118/1.3112364
    • (2009) Med. Phys. , vol.36 , pp. 1566-1575
    • Sterpin, E.1    Salvat, F.2    Olivera, G.3    Vynckier, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.