Tomotherapy: A new concept in the delivery of dynamic conformal radiotherapy
-
0094-2405 10.1118/1.596958.
-
T. R. Mackie, T. W. Holmes, S. Swerdloff, P. J. Reckwerdt, J. O. Deasy, J. Yang, B. R. Paliwal, and T. J. Kinsella, " Tomotherapy: A new concept in the delivery of dynamic conformal radiotherapy.," Med. Phys. 0094-2405 10.1118/1.596958 20, 1709-1719 (1993).
-
(1993)
Med. Phys.
, vol.20
, pp. 1709-1719
-
-
MacKie, T.R.1
Holmes, T.W.2
Swerdloff, S.3
Reckwerdt, P.J.4
Deasy, J.O.5
Yang, J.6
Paliwal, B.R.7
Kinsella, T.J.8
-
2
-
-
33745495381
-
History of tomotherapy
-
0031-9155 10.1088/0031-9155/51/13/R24.
-
T. R. Mackie, " History of tomotherapy.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/51/13/R24 51, R427-R453 (2006).
-
(2006)
Phys. Med. Biol.
, vol.51
-
-
MacKie, T.R.1
-
3
-
-
2342583374
-
Is tomotherapy the future of IMRT
-
0007-1285 10.1259/bjr/22666727.
-
A. W. Beavis, " Is tomotherapy the future of IMRT.," Br. J. Radiol. 0007-1285 10.1259/bjr/22666727 77, 285-295 (2004).
-
(2004)
Br. J. Radiol.
, vol.77
, pp. 285-295
-
-
Beavis, A.W.1
-
4
-
-
0032706348
-
Dose calculations for external photon beams in radiotherapy
-
0031-9155 10.1088/0031-9155/44/11/201.
-
A. Ahnesjö and M. M. Aspradakis, " Dose calculations for external photon beams in radiotherapy.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/44/11/201 44, R99-R155 (1999).
-
(1999)
Phys. Med. Biol.
, vol.44
-
-
Ahnesjö, A.1
Aspradakis, M.M.2
-
5
-
-
0024424112
-
Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media
-
0094-2405 10.1118/1.596360.
-
A. Ahnesjö, " Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media.," Med. Phys. 0094-2405 10.1118/1.596360 16, 577-592 (1989).
-
(1989)
Med. Phys.
, vol.16
, pp. 577-592
-
-
Ahnesjö, A.1
-
6
-
-
14644415951
-
Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels
-
0031-9155 10.1088/0031-9155/50/4/007.
-
W. Lu, G. H. Olivera, M. Chen, P. J. Reckwerdt, and T. R. Mackie, " Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/50/4/007 50, 655-680 (2005).
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 655-680
-
-
Lu, W.1
Olivera, G.H.2
Chen, M.3
Reckwerdt, P.J.4
MacKie, T.R.5
-
7
-
-
34247207650
-
On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: Comparison with Monte Carlo calculations
-
0031-9155 10.1088/0031-9155/52/5/011.
-
A. Fogliata, E. Vanetti, D. Albers, C. Brink, A. Clivi, T. Knöös, G. Nicolini, and L. Cozzi, " On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: Comparison with Monte Carlo calculations.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/52/5/011 52, 1363-1385 (2007).
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 1363-1385
-
-
Fogliata, A.1
Vanetti, E.2
Albers, D.3
Brink, C.4
Clivi, A.5
Knöös, T.6
Nicolini, G.7
Cozzi, L.8
-
8
-
-
15744398473
-
Comparison of inhomogeneity correction algorithms in small photon fields
-
0094-2405 10.1118/1.1861154.
-
A. O. Jones and I. J. Das, " Comparison of inhomogeneity correction algorithms in small photon fields.," Med. Phys. 0094-2405 10.1118/1.1861154 32, 766-776 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 766-776
-
-
Jones, A.O.1
Das, I.J.2
-
9
-
-
0343602910
-
The impact of electron transport on the accuracy of computed dose
-
0094-2405 10.1118/1.599004.
-
M. R. Arnfield, C. H. Siantar, J. Siebers, P. Garmon, L. Cox, and R. Mohan, " The impact of electron transport on the accuracy of computed dose.," Med. Phys. 0094-2405 10.1118/1.599004 27, 1266-1274 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 1266-1274
-
-
Arnfield, M.R.1
Siantar, C.H.2
Siebers, J.3
Garmon, P.4
Cox, L.5
Mohan, R.6
-
10
-
-
7244223251
-
Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium
-
0094-2405 10.1118/1.1788932.
-
P. Carrasco, N. Jornet, M. A. Duch, L. Weber, M. Ginjaume, T. Eudaldo, D. Jurado, A. Ruiz, and M. Ribas, " Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium.," Med. Phys. 0094-2405 10.1118/1.1788932 31, 2899-2911 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 2899-2911
-
-
Carrasco, P.1
Jornet, N.2
Duch, M.A.3
Weber, L.4
Ginjaume, M.5
Eudaldo, T.6
Jurado, D.7
Ruiz, A.8
Ribas, M.9
-
11
-
-
0242521407
-
Monte Carlo modeling of external radiotherapy photon beams
-
0031-9155 10.1088/0031-9155/48/21/R01.
-
F. Verhaegen and J. Seuntjens, " Monte Carlo modeling of external radiotherapy photon beams.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/48/21/R01 48, R107-R164 (2003).
-
(2003)
Phys. Med. Biol.
, vol.48
-
-
Verhaegen, F.1
Seuntjens, J.2
-
12
-
-
33846618618
-
Monte Carlo treatment planning for photon and electron beams
-
0969-806X 10.1016/j.radphyschem.2006.05.015.
-
N. Reynaert, S. C. van der Marck, D. R. Schaart, W. Van der Zee, C. Van Vliet-Vroegindeweij, M. Tomsej, J. Jansen, B. Heijmen, M. Coghe, and C. De Wagter, " Monte Carlo treatment planning for photon and electron beams.," Radiat. Phys. Chem. 0969-806X 10.1016/j.radphyschem.2006.05.015 76, 643-686 (2007).
-
(2007)
Radiat. Phys. Chem.
, vol.76
, pp. 643-686
-
-
Reynaert, N.1
Van Der Marck, S.C.2
Schaart, D.R.3
Van Der Zee, W.4
Van Vliet-Vroegindeweij, C.5
Tomsej, M.6
Jansen, J.7
Heijmen, B.8
Coghe, M.9
De Wagter, C.10
-
13
-
-
36649020653
-
Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
-
0094-2405 10.1118/1.2795842.
-
I. J. Chetty, B. Curran, J. E. Cygler, J. J. DeMarco, G. Ezzell, B. A. Faddegon, I. Kawrakow, P. J. Keall, H. Liu, C. -M. Ma, D. W. O. Rogers, J. Seuntjens, D. Sheikh-Bagheri, and J. V. Siebers, " Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.," Med. Phys. 0094-2405 10.1118/1.2795842 34, 4818-4853 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 4818-4853
-
-
Chetty, I.J.1
Curran, B.2
Cygler, J.E.3
Demarco, J.J.4
Ezzell, G.5
Faddegon, B.A.6
Kawrakow, I.7
Keall, P.J.8
Liu, H.9
Ma, C.-M.10
Rogers, D.W.O.11
Seuntjens, J.12
Sheikh-Bagheri, D.13
Siebers, J.V.14
-
14
-
-
34548711374
-
Monte Carlo simulation of the tomotherapy treatment unit in the static mode using MC HAMMER, a Monte Carlo tool dedicated to tomotherapy
-
1742-6588,. 10.1088/1742-6596/74/1/021019
-
E. Sterpin, M. Tomsej, R. Cravens, F. Salvat, K. Ruchala, G. H. Olivera and S. Vynckier, " Monte Carlo simulation of the tomotherapy treatment unit in the static mode using MC HAMMER, a Monte Carlo tool dedicated to tomotherapy.," J. Phys.: Conf. Ser. 1742-6588 74, 021019 (2007). 10.1088/1742-6596/74/1/021019
-
(2007)
J. Phys.: Conf. Ser.
, vol.74
, pp. 021019
-
-
Sterpin, E.1
Tomsej, M.2
Cravens, R.3
Salvat, F.4
Ruchala, K.5
Olivera, G.H.6
Vynckier, S.7
-
15
-
-
44649183488
-
Analytical model of the binary multileaf collimator of tomotherapy for Monte Carlo simulations
-
1742-6588 10.1088/1742-6596/102/1/012022.
-
E. Sterpin, F. Salvat, G. H. Olivera, and S. Vynckier, " Analytical model of the binary multileaf collimator of tomotherapy for Monte Carlo simulations.," J. Phys.: Conf. Ser. 1742-6588 10.1088/1742-6596/102/1/ 012022 102, 012022 (2008).
-
(2008)
J. Phys.: Conf. Ser.
, vol.102
, pp. 012022
-
-
Sterpin, E.1
Salvat, F.2
Olivera, G.H.3
Vynckier, S.4
-
16
-
-
42949087443
-
Monte Carlo simulation of helical tomotherapy with PENELOPE
-
0031-9155 10.1088/0031-9155/53/8/011.
-
E. Sterpin, F. Salvat, R. Cravens, K. Ruchala, G. H. Olivera, and S. Vynckier, " Monte Carlo simulation of helical tomotherapy with PENELOPE.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/53/8/011 53, 2161-2180 (2008).
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 2161-2180
-
-
Sterpin, E.1
Salvat, F.2
Cravens, R.3
Ruchala, K.4
Olivera, G.H.5
Vynckier, S.6
-
17
-
-
34247599929
-
Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multiplayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator
-
0094-2405 10.1118/1.2727314.
-
E. Sterpin, M. Tomsej, B. De Smedt, N. Reynaert, and S. Vynckier, " Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multiplayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator.," Med. Phys. 0094-2405 10.1118/1.2727314 34, 1665-1677 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 1665-1677
-
-
Sterpin, E.1
Tomsej, M.2
De Smedt, B.3
Reynaert, N.4
Vynckier, S.5
-
18
-
-
33846256274
-
Comparison of 6 MV and 18 MV photons for IMRT treatment of lung cancer
-
0167-8140,. 10.1016/j.radonc.2006.11.016
-
I. Madani, B. Vanderstraeten, S. Bral, M. Coghe, W. De Gersem, C. De Wagter, H. Thierens, and W. De Neve, " Comparison of 6 MV and 18 MV photons for IMRT treatment of lung cancer.," Radiother. Oncol. 0167-8140 82, 63-69 (2007). 10.1016/j.radonc.2006.11.016
-
(2007)
Radiother. Oncol.
, vol.82
, pp. 63-69
-
-
Madani, I.1
Vanderstraeten, B.2
Bral, S.3
Coghe, M.4
De Gersem, W.5
De Wagter, C.6
Thierens, H.7
De Neve, W.8
-
19
-
-
33845194334
-
Comparison of dose-volume histograms of IMRT treatment plans for ethmod sinus cancer computed by advanced treatment planning systems including Monte Carlo
-
0167-8140 10.1016/j.radonc.2006.10.023.
-
L. Paelinck, B. De Smedt, N. Reynaert, M. Coghe, W. De Gersem, C. De Wagter, B. Vanderstraeten, H. Thierens, and W. De Neve, " Comparison of dose-volume histograms of IMRT treatment plans for ethmod sinus cancer computed by advanced treatment planning systems including Monte Carlo.," Radiother. Oncol. 0167-8140 10.1016/j.radonc.2006.10.023 81, 250-256 (2006).
-
(2006)
Radiother. Oncol.
, vol.81
, pp. 250-256
-
-
Paelinck, L.1
De Smedt, B.2
Reynaert, N.3
Coghe, M.4
De Gersem, W.5
De Wagter, C.6
Vanderstraeten, B.7
Thierens, H.8
De Neve, W.9
-
20
-
-
0035996450
-
Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: A comparison between radiochromic films measurements, Monte Carlo simulations, and collapsed cone convolution calculations
-
0094-2405 10.1118/1.1487421.
-
C. Martens, N. Reynaert, C. De Wagter, P. Nilsson, M. Coghe, H. Palmans, H. Thierens, and W. De Neve, " Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: A comparison between radiochromic films measurements, Monte Carlo simulations, and collapsed cone convolution calculations.," Med. Phys. 0094-2405 10.1118/1.1487421 29, 1528-1535 (2002).
-
(2002)
Med. Phys.
, vol.29
, pp. 1528-1535
-
-
Martens, C.1
Reynaert, N.2
De Wagter, C.3
Nilsson, P.4
Coghe, M.5
Palmans, H.6
Thierens, H.7
De Neve, W.8
-
21
-
-
33846882623
-
Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situation
-
0031-9155 10.1088/0031-9155/51/22/005.
-
T. Knöös, E. Wieslander, L. Cozzi, C. Brink, A. Fogliata, D. Albers, H. Nyström, and S. Lassen, " Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situation.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/51/22/005 51, 5785-5807 (2006).
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 5785-5807
-
-
Knöös, T.1
Wieslander, E.2
Cozzi, L.3
Brink, C.4
Fogliata, A.5
Albers, D.6
Nyström, H.7
Lassen, S.8
-
22
-
-
33748297735
-
Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition and pencil beam computations
-
0094-2405 10.1118/1.2241992.
-
B. Vanderstraeten, N. Reynaert, L. Paelinck, I. Madani, C. De Wagter, W. De Gersem, W. De Neve, and H. Thierens, " Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/ superposition and pencil beam computations.," Med. Phys. 0094-2405 10.1118/1.2241992 33, 3149-3157 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 3149-3157
-
-
Vanderstraeten, B.1
Reynaert, N.2
Paelinck, L.3
Madani, I.4
De Wagter, C.5
De Gersem, W.6
De Neve, W.7
Thierens, H.8
-
23
-
-
0033866920
-
Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM
-
0094-2405 10.1118/1.599024.
-
P. Francescon, C. Cavedon, S. Reccanello, and S. Cora, " Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM.," Med. Phys. 0094-2405 10.1118/1.599024 27, 1579-1587 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 1579-1587
-
-
Francescon, P.1
Cavedon, C.2
Reccanello, S.3
Cora, S.4
-
24
-
-
0025266991
-
The validity of the density scaling method in primary electron transport for photon and electron beams
-
0094-2405 10.1118/1.596497.
-
M. K. Woo and J. R. Cunningham, " The validity of the density scaling method in primary electron transport for photon and electron beams.," Med. Phys. 0094-2405 10.1118/1.596497 17, 187-194 (1990).
-
(1990)
Med. Phys.
, vol.17
, pp. 187-194
-
-
Woo, M.K.1
Cunningham, J.R.2
-
25
-
-
0003797116
-
-
OECD Nuclear Energy Agency, Issy-les-Moulineaux, France.
-
F. Salvat, J. M. Fernandez-Varea, and J. Sempau, " PENELOPE-2006: A code system for Monte Carlo simulation of electron and photon transport.," OECD Nuclear Energy Agency, Issy-les-Moulineaux, France, 2006.
-
(2006)
PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport
-
-
Salvat, F.1
Fernandez-Varea, J.M.2
Sempau, J.3
-
26
-
-
16444385104
-
Sensitivity study for CT image use in Monte Carlo treatment planning
-
0031-9155 10.1088/0031-9155/50/5/016.
-
F. Verhaegen and S. Devic, " Sensitivity study for CT image use in Monte Carlo treatment planning.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/50/5/016 50, 937-946 (2005).
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 937-946
-
-
Verhaegen, F.1
Devic, S.2
-
27
-
-
24044552348
-
Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT
-
0031-9155 10.1088/0031-9155/50/17/006.
-
B. De Smedt, B. Vanderstraeten, N. Reynaert, W. De Neve, and H. Thierens, " Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/50/17/006 50, 4005-4019 (2005).
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 4005-4019
-
-
De Smedt, B.1
Vanderstraeten, B.2
Reynaert, N.3
De Neve, W.4
Thierens, H.5
-
28
-
-
0034036210
-
Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
-
0031-9155 10.1088/0031-9155/45/4/313.
-
J. V. Siebers, P. J. Keall, A. E. Nahum, and R. Mohan, " Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/45/ 4/313 45, 983-995 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 983-995
-
-
Siebers, J.V.1
Keall, P.J.2
Nahum, A.E.3
Mohan, R.4
-
29
-
-
33845931294
-
Comparison of the Epson Expression 1680 flatbed and the Vidar VXR-16 Dosimetry PRO film scanners for use in IMRT dosimetry using Gafchromic and radiographic film
-
0094-2405 10.1118/1.2402584.
-
E. Wilcox, G. Daskalov, and L. Nedialkova, " Comparison of the Epson Expression 1680 flatbed and the Vidar VXR-16 Dosimetry PRO film scanners for use in IMRT dosimetry using Gafchromic and radiographic film.," Med. Phys. 0094-2405 10.1118/1.2402584 34, 41-48 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 41-48
-
-
Wilcox, E.1
Daskalov, G.2
Nedialkova, L.3
-
30
-
-
28044452190
-
Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies
-
0094-2405 10.1118/1.2065467.
-
S. T. Chiu-Tsao, Y. Ho, R. Shankar, L. Wang, and L. B. Harrison, " Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies.," Med. Phys. 0094-2405 10.1118/1.2065467 32, 3350-3354 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3350-3354
-
-
Chiu-Tsao, S.T.1
Ho, Y.2
Shankar, R.3
Wang, L.4
Harrison, L.B.5
-
31
-
-
38849173037
-
Accurate dosimetry with Gafchromic EBT film of a 6MV photon beam in water: What level is achievable?
-
0094-2405 10.1118/1.2828196.
-
L. J. van Battum, D. Hoffmans, H. Piersma, and S. Heukelom, " Accurate dosimetry with Gafchromic EBT film of a 6MV photon beam in water: What level is achievable? " Med. Phys. 0094-2405 10.1118/1.2828196 35, 704-716 (2008).
-
(2008)
Med. Phys.
, vol.35
, pp. 704-716
-
-
Van Battum, L.J.1
Hoffmans, D.2
Piersma, H.3
Heukelom, S.4
-
32
-
-
33845931294
-
Comparison of the Epson Expression 1680 flatbed and the Vidar VXR-16 dosimetry PROTM film scanners for use in IMRT dosimetry using Gafchromic and radiographic film
-
0094-2405.
-
E. Wilcox, G. Daskalov, and L. Nedialkova, " Comparison of the Epson Expression 1680 flatbed and the Vidar VXR-16 dosimetry PROTM film scanners for use in IMRT dosimetry using Gafchromic and radiographic film.," Med. Phys. 0094-2405 3441-3448 (2007).
-
(2007)
Med. Phys.
, pp. 3441-3448
-
-
Wilcox, E.1
Daskalov, G.2
Nedialkova, L.3
-
33
-
-
33645519422
-
Accurate skin dose measurements using radiochromic film in clinical applications
-
0094-2405 10.1118/1.2179169.
-
S. Devic, " Accurate skin dose measurements using radiochromic film in clinical applications.," Med. Phys. 0094-2405 10.1118/1.2179169 33, 1116-1124 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 1116-1124
-
-
Devic, S.1
-
34
-
-
10744226022
-
Dosimetric considerations for patients with HIP prostheses undergoing irradiation. Report on the AAPM Radiation Therapy Committeee Task Group 63
-
0094-2405 10.1118/1.1565113.
-
C. Reft, R. Alecu, I. J. Das, B. J. Gerbi, P. Keall, E. Lief, B. J. Mijnheer, N. Papanikolaou, C. Sibat, and J. Van Dyk, " Dosimetric considerations for patients with HIP prostheses undergoing irradiation. Report on the AAPM Radiation Therapy Committeee Task Group 63.," Med. Phys. 0094-2405 10.1118/1.1565113 30, 1162-1182 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 1162-1182
-
-
Reft, C.1
Alecu, R.2
Das, I.J.3
Gerbi, B.J.4
Keall, P.5
Lief, E.6
Mijnheer, B.J.7
Papanikolaou, N.8
Sibat, C.9
Van Dyk, J.10
-
35
-
-
58149236841
-
A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy
-
0031-9155,. 10.1088/0031-9155/53/24/011
-
I. M. Gagne, W. Ansbacher, S. Zavgorodni, C. Popescu and W. A. Beckham " A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy., Phys. Med. Biol. 0031-9155 53, 7167-7185 (2008). 10.1088/0031-9155/53/24/011
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 7167-7185
-
-
Gagne, I.M.1
Ansbacher, W.2
Zavgorodni, S.3
Popescu, C.4
Beckham, W.A.5
|