메뉴 건너뛰기




Volumn 37, Issue 6, 2010, Pages 2466-2472

A method to correct the influence of carbon fiber couchtop and patient positioning device on image quality of cone beam CT

Author keywords

Cone beam computed tomography; Couchtop; Image quality; Positioning device

Indexed keywords

DISEASES; ELECTROMAGNETIC WAVE ATTENUATION; FIBERS; GRAPHITE FIBERS; IMAGE ENHANCEMENT; IMAGE QUALITY; IMAGE RESOLUTION; PHANTOMS; QUALITY CONTROL;

EID: 77953489247     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3425999     Document Type: Article
Times cited : (4)

References (19)
  • 1
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • DOI 10.1016/S0360-3016(02)02884-5, PII S0360301602028845
    • D. A. Jaffray, J. H. Siewerdsen, J. W. Wong, and A. A. Martinez, " Flat-panel cone-beam computed tomography for image-guided radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 53 (5), 1337-1349 (2002). 10.1016/S0360-3016(02)02884-5 (Pubitemid 34787872)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.53 , Issue.5 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3    Martinez, A.A.4
  • 2
    • 33645347668 scopus 로고    scopus 로고
    • Overview of image-guided radiation therapy
    • ZZZZZZ 0739-0211 (),. 10.1016/j.meddos.2005.12.004
    • L. Xing, B. Thorndyke, E. Schreibmann, Y. Yang, T. F. Li, G. Y. Kim, G. Luxton, and A. Koong, " Overview of image-guided radiation therapy.," Med. Dosim. ZZZZZZ 0739-0211 31 (2), 91-112 (2006). 10.1016/j.meddos.2005.12.004
    • (2006) Med. Dosim. , vol.31 , Issue.2 , pp. 91-112
    • Xing, L.1    Thorndyke, B.2    Schreibmann, E.3    Yang, Y.4    Li, T.F.5    Kim, G.Y.6    Luxton, G.7    Koong, A.8
  • 3
    • 33846883177 scopus 로고    scopus 로고
    • Advanced imaging and guidance system for use in intensity modulated RT
    • (Springer, Berlin Heidelberg), 10.1007/3-540-30356-1-17
    • D. A. Jaffray, K. K. Brock, and M. B. Sharpe, " Advanced imaging and guidance system for use in intensity modulated RT.," Image-Guided IMRT (Springer, Berlin Heidelberg, 2006), pp. 217-227. 10.1007/3-540-30356-1-17
    • (2006) Image-Guided IMRT , pp. 217-227
    • Jaffray, D.A.1    Brock, K.K.2    Sharpe, M.B.3
  • 4
    • 33846826893 scopus 로고    scopus 로고
    • Reducing metal artifacts in cone-beam CT images by preprocessing projection data
    • IOBPD3 0360-3016 (),. 10.1016/j.ijrob2006.09.045
    • Y. Zhang, L. Zhang, X. R. Zhu, A. K. Lee, M. Chambers, and L. Dong, " Reducing metal artifacts in cone-beam CT images by preprocessing projection data.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 67 (3), 924-932 (2007). 10.1016/j.ijrobp.2006.09.045
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.67 , Issue.3 , pp. 924-932
    • Zhang, Y.1    Zhang, L.2    Zhu, X.R.3    Lee, A.K.4    Chambers, M.5    Dong, L.6
  • 5
    • 22144476562 scopus 로고    scopus 로고
    • Metal artifact reduction for CT based on sinusoidal description
    • JXSTE5 0895-3996 ().
    • J. J. Liu, S. R. Watt-Smith, and S. M. Smith, " Metal artifact reduction for CT based on sinusoidal description.," J. X-Ray Sci. Technol. JXSTE5 0895-3996 13 (2), 85-96 (2005).
    • (2005) J. X-Ray Sci. Technol. , vol.13 , Issue.2 , pp. 85-96
    • Liu, J.J.1    Watt-Smith, S.R.2    Smith, S.M.3
  • 6
    • 45749103203 scopus 로고    scopus 로고
    • Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
    • DOI 10.1088/0031-9155/53/11/009, PII S0031915508683785
    • J. Wang, T. Li, Z. Liang, and L. Xing, " Dose reduction in kilovotage cone-beam computed tomography for radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 53 (11), 2897-2909 (2008). 10.1088/0031-9155/53/11/ 009 (Pubitemid 351868612)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2897-2909
    • Wang, J.1    Li, T.2    Liang, Z.3    Xing, L.4
  • 7
    • 31044451240 scopus 로고    scopus 로고
    • A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT
    • DOI 10.1118/1.2148916
    • J. H. Siewerdsen, M. J. Daly, and B. Bakhtiar, " A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT.," Med. Phys. MPHYA6 0094-2405 33 (1), 187-197 (2006). 10.1118/1.2148916 (Pubitemid 43121048)
    • (2006) Medical Physics , vol.33 , Issue.1 , pp. 187-197
    • Siewerdsen, J.H.1    Daly, M.J.2    Bakhtiar, B.3    Moseley, D.J.4    Richard, S.5    Keller, H.6    Jaffray, D.A.7
  • 8
    • 58149115069 scopus 로고    scopus 로고
    • The influence of bowtie filtration on cone-beam CT image quality
    • MPHYA6 0094-2405 (),. 10.1118/1.3017470
    • N. Mail, D. J. Moseley, J. H. Siewerdsen, and D. A. Jaffray, " The influence of bowtie filtration on cone-beam CT image quality.," Med. Phys. MPHYA6 0094-2405 36 (1), 22-32 (2009). 10.1118/1.3017470
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 22-32
    • Mail, N.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4
  • 9
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • DOI 10.1118/1.1711475
    • R. Ning, X. Tang, and D. Conover, " X-ray scatter correction algorithm for cone beam CT imaging.," Med. Phys. MPHYA6 0094-2405 31 (5), 1195-1202 (2004). 10.1118/1.1711475 (Pubitemid 38656792)
    • (2004) Medical Physics , vol.31 , Issue.5 , pp. 1195-1202
    • Ning, R.1    Tang, X.2    Conover, D.3
  • 11
    • 11244314035 scopus 로고    scopus 로고
    • The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors
    • DOI 10.1118/1.1819789
    • J. H. Siewerdsen, D. J. Moseley, and B. Bakhtiar, " The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors.," Med. Phys. MPHYA6 0094-2405 31 (12), 3506-3520 (2004). 10.1118/1.1819789 (Pubitemid 40065003)
    • (2004) Medical Physics , vol.31 , Issue.12 , pp. 3506-3520
    • Siewerdsen, J.H.1    Moseley, D.J.2    Bakhtiar, B.3    Richard, S.4    Jaffray, D.A.5
  • 12
    • 85027218666 scopus 로고    scopus 로고
    • Elekta, Clinical User Manual for XVI R3.5, General Release.
    • Elekta, Clinical User Manual for XVI R3.5, General Release (2006).
    • (2006)
  • 13
    • 0021445363 scopus 로고
    • Practical cone-beam algorithm
    • JOAOD6 0740-3232 (),. 10.1364/JOSAA.1.000612
    • L. A. Feldkamp, L. C. Davis, and J. W. Kress, " Practical cone-beam algorithm.," J. Opt. Soc. Am. A JOAOD6 0740-3232 1 (6), 612-619 (1984). 10.1364/JOSAA.1.000612
    • (1984) J. Opt. Soc. Am. A , vol.1 , Issue.6 , pp. 612-619
    • Feldkamp, L.A.1    Davis, L.C.2    Kress, J.W.3
  • 14
    • 85027221927 scopus 로고    scopus 로고
    • The Phantom Laboratory, Catphan 500 and 600 Manual.
    • The Phantom Laboratory, Catphan 500 and 600 Manual (2006).
    • (2006)
  • 15
    • 0033623770 scopus 로고    scopus 로고
    • 2 amorphous silicon flat panel x-ray detector for radiographic imaging applications
    • DOI 10.1118/1.599010
    • P. R. Granfors and R. Aufrichtig, " Performance of a 41×41 cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications.," Med. Phys. MPHYA6 0094-2405 27 (6), 1324-1331 (2000). 10.1118/1.599010 (Pubitemid 30416101)
    • (2000) Medical Physics , vol.27 , Issue.6 , pp. 1324-1331
    • Granfors, P.R.1    Aufrichtig, R.2
  • 16
    • 2442706565 scopus 로고    scopus 로고
    • Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: Image quality and dose measurements
    • DOI 10.1118/1.1688212
    • F. Cremers, T. Frenzel, C. Kausch, D. Albers, T. Schönborn, and R. Schmidt, " Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: Image quality and dose measurements.," Med. Phys. MPHYA6 0094-2405 31 (5), 985-996 (2004). 10.1118/1.1688212 (Pubitemid 38656765)
    • (2004) Medical Physics , vol.31 , Issue.5 , pp. 985-996
    • Cremers, F.1    Frenzel, Th.2    Kausch, C.3    Albers, D.4    Schonborn, T.5    Schmidt, R.6
  • 17
    • 53049101856 scopus 로고    scopus 로고
    • Evaluating the influence of the Siemens IGRT carbon fiber tabletop in head-and-neck cancer IMRT
    • RAONDT 0167-8140,. 10.1016/j.radonc.2008.06.011
    • E. Spezi, A. L. Angelini, F. Romani, A. Guido, F. Bunkheila, M. Ntreta, and A. Ferri, " Evaluating the influence of the Siemens IGRT carbon fiber tabletop in head-and-neck cancer IMRT.," Radiother. Oncol. RAONDT 0167-8140 89, 114-122 (2008). 10.1016/j.radonc.2008.06.011
    • (2008) Radiother. Oncol. , vol.89 , pp. 114-122
    • Spezi, E.1    Angelini, A.L.2    Romani, F.3    Guido, A.4    Bunkheila, F.5    Ntreta, M.6    Ferri, A.7
  • 18
    • 34548280321 scopus 로고    scopus 로고
    • Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop
    • JACMFG 1526-9914 (),. 10.1120/jacmv7i3.2247
    • W. K. Myint, M. Niedbala, D. Wilkins, and L. H. Gerig, " Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop.," J. Appl. Clin. Med. Phys. JACMFG 1526-9914 7 (3), 21-27 (2006). 10.1120/jacmp.v7i3.2247
    • (2006) J. Appl. Clin. Med. Phys. , vol.7 , Issue.3 , pp. 21-27
    • Myint, W.K.1    Niedbala, M.2    Wilkins, D.3    Gerig, L.H.4
  • 19
    • 54949116628 scopus 로고    scopus 로고
    • Modeling of carbon fiber couchtop attenuation properties with a commercial treatment planning system
    • MPHYA6 0094-2405 (),. 10.1118/1.2982135
    • I. B. Mihaylov, P. Corry, Y. Yan, V. Ratanatharathorn, and E. G. Moros, " Modeling of carbon fiber couchtop attenuation properties with a commercial treatment planning system.," Med. Phys. MPHYA6 0094-2405 35 (11), 4982-4988 (2008). 10.1118/1.2982135
    • (2008) Med. Phys. , vol.35 , Issue.11 , pp. 4982-4988
    • Mihaylov, I.B.1    Corry, P.2    Yan, Y.3    Ratanatharathorn, V.4    Moros, E.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.