메뉴 건너뛰기




Volumn 37, Issue 11, 2010, Pages 5618-5626

In-plane visibility of lesions using breast tomosynthesis and digital mammography

Author keywords

breast tomosynthesis; digital mammography; forced choice; observer performance; signal detection

Indexed keywords

MAMMOGRAPHY; SIGNAL DETECTION; TOMOGRAPHY; VISIBILITY;

EID: 77953340413     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3488899     Document Type: Article
Times cited : (34)

References (39)
  • 1
    • 0037117140 scopus 로고    scopus 로고
    • Long-term effects of mammography screening: Updated overview of the Swedish randomised trials
    • DOI 10.1016/S0140-6736(02)08020-0
    • L. Nyström, I. Andersson, N. Bjurstam, J. Frisell, B. Nordenskjöld, and L. E. Rutqvist, " Long-term effects of mammography screening: Updated overview of the Swedish randomised trials.," Lancet LANCAO 0140-6736 359, 909-919 (2002). 10.1016/S0140-6736(02)08020-0 (Pubitemid 34246378)
    • (2002) Lancet , vol.359 , Issue.9310 , pp. 909-919
    • Nystrom, L.1    Andersson, I.2    Bjurstam, N.3    Frisell, J.4    Nordenskjold, B.5    Rutqvist, L.E.6
  • 3
    • 2942711553 scopus 로고    scopus 로고
    • Screen-film mammography versus full-field digital mammography with soft-copy reading: Randomized trial in a population-based screening program - The Oslo II study
    • DOI 10.1148/radiol.2321031624
    • P. Skaane and A. Skjennald, " Screen-film mammography versus full-field digital mammography with soft-copy reading: Randomized trial in a population-based screening program-The Oslo II study.," Radiology RADLAX 0033-8419 232, 197-204 (2004). 10.1148/radiol.2321031624 (Pubitemid 38787838)
    • (2004) Radiology , vol.232 , Issue.1 , pp. 197-204
    • Skaane, P.1    Skjennald, A.2
  • 4
    • 0032783631 scopus 로고    scopus 로고
    • Estimation of the noisy component of anatomical backgrounds
    • DOI 10.1118/1.598632
    • F. O. Bochud, J. F. Valley, F. R. Verdun, C. Hessler, and P. Schnyder, " Estimation of the noisy component of anatomical backgrounds.," Med. Phys. MPHYA6 0094-2405 26, 1365-1370 (1999). 10.1118/1.598632 (Pubitemid 29334805)
    • (1999) Medical Physics , vol.26 , Issue.7 , pp. 1365-1370
    • Bochud, F.O.1    Valley, J.-F.2    Verdun, F.R.3    Hessler, C.4    Schnyder, P.5
  • 5
    • 0035049369 scopus 로고    scopus 로고
    • Human observer detection experiments with mammograms and power-law noise
    • DOI 10.1118/1.1355308
    • A. E. Burgess, F. L. Jacobson, and P. F. Judy, " Human observer detection experiments with mammograms and power-law noise.," Med. Phys. MPHYA6 0094-2405 28, 419-437 (2001). 10.1118/1.1355308 (Pubitemid 32323293)
    • (2001) Medical Physics , vol.28 , Issue.4 , pp. 419-437
    • Burgess, A.E.1    Jacobson, F.L.2    Judy, P.F.3
  • 6
    • 33745148987 scopus 로고    scopus 로고
    • Analyzing the Effect of dose reduction on the detection of mammographic lesions using mathematical observer models
    • DOI 10.1117/12.656378, Medical Imaging 2006: Image Perception, Observer Performance, and Technology Assessment
    • A. S. Chawla, R. Saunders, C. K. Abbey, D. Delong, and E. Samei, " Analyzing the effect of dose reduction on the detection of mammographic lesions using mathematical observer models.," Proc. SPIE PSISDG 0277-786X 6146, 61460I.1-61460I.12 (2006). 10.1117/12.656378 (Pubitemid 43894756)
    • (2006) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.6146
    • Chawla, A.S.1    Saunders, R.2    Abbey, C.3    Delong, D.4    Samei, E.5
  • 8
    • 34548311949 scopus 로고    scopus 로고
    • Dose reduction and its influence on diagnostic accuracy and radiation risk in digital mammography: An observer performance study using an anthropomorphic breast phantom
    • DOI 10.1259/bjr/29933797
    • T. Svahn, B. Hemdal, M. Ruschin, D. Chakraborty, I. Andersson, A. Tingberg, and S. Mattsson, " Possibility of absorbed dose reduction and its influence on radiation risk estimates in digital mammography: An anthropomorphic breast phantom JAFROC study.," Br. J. Radiol. BJRAAP 0007-1285 80, 557-562 (2007). 10.1259/bjr/29933797 (Pubitemid 47343083)
    • (2007) British Journal of Radiology , vol.80 , Issue.955 , pp. 557-562
    • Svahn, T.1    Hemdal, B.2    Ruschin, M.3    Chakraborty, D.P.4    Andersson, I.5    Tingberg, A.6    Mattson, S.7
  • 10
    • 56349132626 scopus 로고    scopus 로고
    • Breast tomosynthesis and digital mammography: A comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings
    • ZZZZZZ 0938-7994,. 10.1007/s00330-008-1076-9
    • I. Andersson, D. M. Ikeda, S. Zackrisson, M. Ruschin, T. Svahn, P. Timberg, and A. Tingberg, " Breast tomosynthesis and digital mammography: A comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings.," Eur. Radiol. ZZZZZZ 0938-7994 18, 2817-2825 (2008). 10.1007/s00330-008-1076-9
    • (2008) Eur. Radiol. , vol.18 , pp. 2817-2825
    • Andersson, I.1    Ikeda, D.M.2    Zackrisson, S.3    Ruschin, M.4    Svahn, T.5    Timberg, P.6    Tingberg, A.7
  • 11
    • 66449089773 scopus 로고    scopus 로고
    • Tomosynthesis imaging: At a translational crossroads
    • MPHYA6 0094-2405,. 10.1118/1.3120285
    • J. T. Dobbins III, " Tomosynthesis imaging: At a translational crossroads.," Med. Phys. MPHYA6 0094-2405 36, 1956-1967 (2009). 10.1118/1.3120285
    • (2009) Med. Phys. , vol.36 , pp. 1956-1967
    • Dobbins III, J.T.1
  • 16
    • 33645524546 scopus 로고    scopus 로고
    • A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging
    • MPHYA6 0094-2405,. 10.1118/1.2174127
    • X. Gong, S. J. Glick, B. Liu, A. A. Vedula, and S. Thacker, " A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging.," Med. Phys. MPHYA6 0094-2405 33, 1041-1052 (2006). 10.1118/1.2174127
    • (2006) Med. Phys. , vol.33 , pp. 1041-1052
    • Gong, X.1    Glick, S.J.2    Liu, B.3    Vedula, A.A.4    Thacker, S.5
  • 18
    • 35148874776 scopus 로고    scopus 로고
    • A new approach to digital breast tomosynthesis for breast cancer screening
    • DOI 10.1117/12.713677, Medical Imaging 2007: Physics of Medical Imaging
    • R. M. Nishikawa, I. Reiser, and S. Payam, " A new approach to digital breast tomosynthesis for breast cancer screening.," Proc. SPIE PSISDG 0277-786X 6510, 65103C.1-65103C.8 (2007). 10.1117/12.713677 (Pubitemid 47550221)
    • (2007) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.6510 , Issue.PART 2
    • Nishikawa, R.M.1    Reiser, I.2    Seifi, P.3
  • 20
    • 0005642443 scopus 로고    scopus 로고
    • A theoretical framework for filtered backprojection in tomosynthesis
    • PSISDG 0277-786X,. 10.1117/12.310839
    • G. Lauritsch and W. Haerer, " A theoretical framework for filtered backprojection in tomosynthesis.," Proc. SPIE PSISDG 0277-786X 3338, 1127-1137 (1998). 10.1117/12.310839
    • (1998) Proc. SPIE , vol.3338 , pp. 1127-1137
    • Lauritsch, G.1    Haerer, W.2
  • 21
    • 33745351039 scopus 로고    scopus 로고
    • Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device
    • DOI 10.1117/12.651380, Medical Imaging 2006: Physics of Medical Imaging
    • T. Mertelmeier, J. Orman, and W. Haerer, " Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device.," Proc. SPIE PSISDG 0277-786X 6142, 61420F.1-61420F.12 (2006). 10.1117/12.651380 (Pubitemid 43944866)
    • (2006) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.6142
    • Mertelmeier, T.1    Orman, J.2    Haerer, W.3    Dudam, M.K.4
  • 23
    • 56749186140 scopus 로고    scopus 로고
    • Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach
    • MPHYA6 0094-2405,. 10.1118/1.2996110
    • Y. H. Hu, B. Zhao, and W. Zhao, " Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach.," Med. Phys. MPHYA6 0094-2405 35, 5242-5252 (2008). 10.1118/1.2996110
    • (2008) Med. Phys. , vol.35 , pp. 5242-5252
    • Hu, Y.H.1    Zhao, B.2    Zhao, W.3
  • 24
    • 58149136863 scopus 로고    scopus 로고
    • Experimental validation of a three-dimensional linear system model for breast tomosynthesis
    • MPHYA6 0094-2405,. 10.1118/1.3040178
    • B. Zhao, J. Zhou, Y. H. Hu, T. Mertelmeier, J. Ludwig, and W. Zhao, " Experimental validation of a three-dimensional linear system model for breast tomosynthesis.," Med. Phys. MPHYA6 0094-2405 36, 240-251 (2009). 10.1118/1.3040178
    • (2009) Med. Phys. , vol.36 , pp. 240-251
    • Zhao, B.1    Zhou, J.2    Hu, Y.H.3    Mertelmeier, T.4    Ludwig, J.5    Zhao, W.6
  • 25
    • 0033735247 scopus 로고    scopus 로고
    • Scatter/primary in mammography: Comprehensive results
    • MPHYA6 0094-2405,. 10.1118/1.1312812
    • J. M. Boone, K. K. Lindfors, V. N. Cooper III, and J. A. Seibert, " Scatter/primary in mammography: Comprehensive results.," Med. Phys. MPHYA6 0094-2405 27, 2408-2416 (2000). 10.1118/1.1312812
    • (2000) Med. Phys. , vol.27 , pp. 2408-2416
    • Boone, J.M.1    Lindfors, K.K.2    Cooper III, V.N.3    Seibert, J.A.4
  • 26
    • 70349659698 scopus 로고    scopus 로고
    • Evaluation of scatter effects on image quality for breast tomosynthesis
    • MPHYA6 0094-2405,. 10.1118/1.3215926
    • G. Wu, J. G. Mainprize, J. M. Boone, and M. J. Yaffe, " Evaluation of scatter effects on image quality for breast tomosynthesis.," Med. Phys. MPHYA6 0094-2405 36, 4425-4432 (2009). 10.1118/1.3215926
    • (2009) Med. Phys. , vol.36 , pp. 4425-4432
    • Wu, G.1    Mainprize, J.G.2    Boone, J.M.3    Yaffe, M.J.4
  • 28
    • 0034133191 scopus 로고    scopus 로고
    • Visual signal detection in structured backgrounds. IV. Figures of merit for model performance in multiple-alternative forced-choice detection tasks with correlated responses
    • ZZZZZZ 1084-7529,. 10.1364/JOSAA.17.000206
    • M. P. Eckstein, C. K. Abbey, and F. O. Bochud, " Visual signal detection in structured backgrounds. IV. Figures of merit for model performance in multiple-alternative forced-choice detection tasks with correlated responses.," J. Opt. Soc. Am. A Opt. Image Sci. Vis ZZZZZZ 1084-7529 17, 206-217 (2000). 10.1364/JOSAA.17.000206
    • (2000) J. Opt. Soc. Am. A Opt. Image Sci. Vis , vol.17 , pp. 206-217
    • Eckstein, M.P.1    Abbey, C.K.2    Bochud, F.O.3
  • 29
    • 0028999842 scopus 로고
    • Comparison of receiver operating characteristic and forced choice observer performance measurement methods
    • MPHYA6 0094-2405,. 10.1118/1.597576
    • A. E. Burgess, " Comparison of receiver operating characteristic and forced choice observer performance measurement methods.," Med. Phys. MPHYA6 0094-2405 22, 643-655 (1995). 10.1118/1.597576
    • (1995) Med. Phys. , vol.22 , pp. 643-655
    • Burgess, A.E.1
  • 30
    • 33750356996 scopus 로고    scopus 로고
    • How Do Lesion Size and Random Noise Affect Detection Performance in Digital Mammography?
    • DOI 10.1016/j.acra.2006.07.011, PII S1076633206003813
    • W. Huda, K. M. Ogden, E. M. Scalzetti, D. R. Dance, and E. A. Bertrand, " How do lesion size and random noise affect detection performance in digital mammography?," Acad. Radiol. ZZZZZZ 1076-6332 13, 1355-1366 (2006). 10.1016/j.acra.2006.07.011 (Pubitemid 44633699)
    • (2006) Academic Radiology , vol.13 , Issue.11 , pp. 1355-1366
    • Huda, W.1    Ogden, K.M.2    Scalzetti, E.M.3    Dance, D.R.4    Bertrand, E.A.5
  • 32
    • 65449139477 scopus 로고    scopus 로고
    • Comparison of power spectra for tomosynthesis projections and reconstructed images
    • MPHYA6 0094-2405,. 10.1118/1.3116774
    • E. Engström, I. Reiser, and R. Nishikawa, " Comparison of power spectra for tomosynthesis projections and reconstructed images.," Med. Phys. MPHYA6 0094-2405 36, 1753-1758 (2009). 10.1118/1.3116774
    • (2009) Med. Phys. , vol.36 , pp. 1753-1758
    • Engström, E.1    Reiser, I.2    Nishikawa, R.3
  • 34
    • 77950553921 scopus 로고    scopus 로고
    • Task-based assessment of breast tomosynthesis: Effect of acquisition parameters and quantum noise
    • MPHYA6 0094-2405,. 10.1118/1.3357288
    • I. Reiser and R. M. Nishikawa, " Task-based assessment of breast tomosynthesis: Effect of acquisition parameters and quantum noise.," Med. Phys. MPHYA6 0094-2405 37, 1591-1600 (2010). 10.1118/1.3357288
    • (2010) Med. Phys. , vol.37 , pp. 1591-1600
    • Reiser, I.1    Nishikawa, R.M.2
  • 35
    • 66449115784 scopus 로고    scopus 로고
    • Evaluation of a variable dose acquisition technique for microcalcification and mass detection in digital breast tomosynthesis
    • MPHYA6 0094-2405,. 10.1118/1.3116902
    • M. Das, H. C. Gifford, J. M. O'Connor, and S. J. Glick, " Evaluation of a variable dose acquisition technique for microcalcification and mass detection in digital breast tomosynthesis.," Med. Phys. MPHYA6 0094-2405 36, 1976-1984 (2009). 10.1118/1.3116902
    • (2009) Med. Phys. , vol.36 , pp. 1976-1984
    • Das, M.1    Gifford, H.C.2    O'Connor, J.M.3    Glick, S.J.4
  • 36
    • 42949103956 scopus 로고    scopus 로고
    • Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system
    • DOI 10.1118/1.2903425
    • B. Zhao and W. Zhao, " Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system.," Med. Phys. MPHYA6 0094-2405 35, 1978-1987 (2008). 10.1118/1.2903425 (Pubitemid 351614813)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 1978-1987
    • Zhao, B.1    Zhao, W.2
  • 37
    • 78149437919 scopus 로고    scopus 로고
    • Proceedings of the Seventh International Workshoon Digital Mammography (IWDM 2004), p, (unpublished).
    • L. Baetz, J. Eser, and T. Mertelmeier, " Detector performance of the new Siemens FFDM system.," Proceedings of the Seventh International Workshop on Digital Mammography (IWDM 2004), pp. 23-30, 2005 (unpublished).
    • (2005) Detector Performance of the New Siemens FFDM System , pp. 23-30
    • Baetz, L.1    Eser, J.2    Mertelmeier, T.3
  • 38
    • 14644435701 scopus 로고    scopus 로고
    • Physical characterization of a prototype selenium-based full field digital mammography detector
    • DOI 10.1118/1.1855033
    • R. S. Saunders, Jr., E. Samei, J. L. Jesneck, and J. Y. Lo, " Physical characterization of a prototype selenium-based full field digital mammography detector.," Med. Phys. MPHYA6 0094-2405 32, 588-599 (2005). 10.1118/1.1855033 (Pubitemid 40322341)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 588-599
    • Saunders Jr., R.S.1    Samei, E.2    Jesneck, J.L.3    Lo, J.Y.4
  • 39
    • 85027226919 scopus 로고    scopus 로고
    • (private communication).
    • T. Mertelmeier (private communication), 2010.
    • (2010)
    • Mertelmeier, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.