-
4
-
-
70350209285
-
ICRP publication 102: Managing patient dose in multi-detector computed tomography (MDCT)
-
International Commission on Radiological Protection
-
International Commission on Radiological Protection. ICRP publication 102: managing patient dose in multi-detector computed tomography (MDCT). Ann ICRP 2007;37:1-79.
-
(2007)
Ann ICRP
, vol.37
, pp. 1-79
-
-
-
5
-
-
77950882237
-
Patient dose reduction methods in computerized tomography procedures: A review
-
Aweda MA, Arogundade RA. Patient dose reduction methods in computerized tomography procedures: a review. Int J Phys Sci 2007;2:1-9.
-
(2007)
Int J Phys Sci
, vol.2
, pp. 1-9
-
-
Aweda, M.A.1
Arogundade, R.A.2
-
6
-
-
44649159674
-
Technical approaches to the optimisation of CT
-
Kalender WA, Buchenau S, Deak P, Kellermeier M, Langner O, van Straten M, et al. Technical approaches to the optimisation of CT. Phys Med 2008;24:71-79
-
(2008)
Phys Med
, vol.24
, pp. 71-79
-
-
Kalender, W.A.1
Buchenau, S.2
Deak, P.3
Kellermeier, M.4
Langner, O.5
Van Straten, M.6
-
7
-
-
1342266221
-
Strategies for CT radiation dose optimization
-
Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JA, et al. Strategies for CT radiation dose optimization. Radiology 2004;230:619-628
-
(2004)
Radiology
, vol.230
, pp. 619-628
-
-
Kalra, M.K.1
Maher, M.M.2
Toth, T.L.3
Hamberg, L.M.4
Shepard, J.A.5
-
8
-
-
27744466794
-
Automatic exposure control in CT: Are we done yet?
-
McCollough CH. Automatic exposure control in CT: are we done yet? Radiology 2005;237:755-756
-
(2005)
Radiology
, vol.237
, pp. 755-756
-
-
McCollough, C.H.1
-
10
-
-
31544452752
-
Assessment of tube current modulation in pelvic CT
-
Iball GR, Brettle DS, Moore AC. Assessment of tube current modulation in pelvic CT. Br J Radiol 2006;79:62-70.
-
(2006)
Br J Radiol
, vol.79
, pp. 62-70
-
-
Iball, G.R.1
Brettle, D.S.2
Moore, A.C.3
-
11
-
-
34347392698
-
Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: Experimental assessment on pediatric phantoms
-
Brisse HJ, Madec L, Gaboriaud G, Lemoine T, Savignoni A, Neuenschwander S, et al. Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms. Med Phys 2007;34:3018-3033
-
(2007)
Med Phys
, vol.34
, pp. 3018-3033
-
-
Brisse, H.J.1
Madec, L.2
Gaboriaud, G.3
Lemoine, T.4
Savignoni, A.5
Neuenschwander, S.6
-
12
-
-
45149121094
-
Comparison between 3-D and z-axis automatic tube current modulation technique in multidetector-row CT
-
Matsubara K, Koshida K, Suzuki M, Tsujii H, Yamamoto T, Matsui O. Comparison between 3-D and z-axis automatic tube current modulation technique in multidetector-row CT. Radiat Prot Dosimetry 2008;128:106-111
-
(2008)
Radiat Prot Dosimetry
, vol.128
, pp. 106-111
-
-
Matsubara, K.1
Koshida, K.2
Suzuki, M.3
Tsujii, H.4
Yamamoto, T.5
Matsui, O.6
-
13
-
-
33645830709
-
Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
-
Rizzo S, Kalra M, Schmidt B, Dalal T, Suess C, Flohr T, et al. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. Am J Roentgenol 2006; 186:673-679
-
(2006)
Am J Roentgenol
, vol.186
, pp. 673-679
-
-
Rizzo, S.1
Kalra, M.2
Schmidt, B.3
Dalal, T.4
Suess, C.5
Flohr, T.6
-
14
-
-
3242783182
-
Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis
-
Kalra MK, Maher MM, Toth TL, Kamath RS, Halpern EF, Saini S. Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 2004;232:347-353
-
(2004)
Radiology
, vol.232
, pp. 347-353
-
-
Kalra, M.K.1
Maher, M.M.2
Toth, T.L.3
Kamath, R.S.4
Halpern, E.F.5
Saini, S.6
-
15
-
-
33746532552
-
The influences of tube voltage and scan direction on combined tube current modulation: A phantom study
-
Goo HW, Suh DS. The influences of tube voltage and scan direction on combined tube current modulation: a phantom study. Pediatr Radiol 2006;36:833-840
-
(2006)
Pediatr Radiol
, vol.36
, pp. 833-840
-
-
Goo, H.W.1
Suh, D.S.2
-
16
-
-
25144433343
-
Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation
-
Mulkens TH, Bellinck P, Baeyaert M, Ghysen D, Van Dijck X, Mussen E, et al. Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 2005;237: 213-223
-
(2005)
Radiology
, vol.237
, pp. 213-223
-
-
Mulkens, T.H.1
Bellinck, P.2
Baeyaert, M.3
Ghysen, D.4
Van Dijck, X.5
Mussen, E.6
-
17
-
-
33751228740
-
Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose
-
Namasivayam S, Kalra MK, Pottala KM, Waldrop SM, Hudgins PA. Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. Am J Neuroradiol 2006;27:2221-2225
-
(2006)
Am J Neuroradiol
, vol.27
, pp. 2221-2225
-
-
Namasivayam, S.1
Kalra, M.K.2
Pottala, K.M.3
Waldrop, S.M.4
Hudgins, P.A.5
-
18
-
-
34548501348
-
CT-automatic exposure control devices: What are their performances?
-
DOI 10.1016/j.nima.2007.06.117, PII S0168900207013083, Imaging 2006 Proceedings of the 3rd International Conference on Imaging Techniques in Subatomic Physics, Astrophysics, Medicine, Biology and Industry
-
Gutierrez D, Schmidt S, Denys A, Schnyder P, Bochud FO, Verdun FR. CT-automatic exposure control devices: What are their performances? Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2007;580:990-995 (Pubitemid 47379925)
-
(2007)
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
, vol.580
, Issue.2
, pp. 990-995
-
-
Gutierrez, D.1
Schmidt, S.2
Denys, A.3
Schnyder, P.4
Bochud, F.O.5
Verdun, F.R.6
-
19
-
-
70349778129
-
Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom
-
Rampado O, Marchisio F, Izzo A, Garelli E, Bianchi CC, Gandini G, et al. Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom. Eur J Radiol 2009; 72:181-187
-
(2009)
Eur J Radiol
, vol.72
, pp. 181-187
-
-
Rampado, O.1
Marchisio, F.2
Izzo, A.3
Garelli, E.4
Bianchi, C.C.5
Gandini, G.6
-
20
-
-
52949134425
-
Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality
-
Papadakis AE, Perisinakis K, Damilakis J. Automatic exposure control in pediatric and adult multidetector CT examinations: a phantom study on dose reduction and image quality. Med Phys 2008;35:4567-4576
-
(2008)
Med Phys
, vol.35
, pp. 4567-4576
-
-
Papadakis, A.E.1
Perisinakis, K.2
Damilakis, J.3
-
21
-
-
77953327950
-
The effect of different adaptation strengths on image quality and radiation dose using Siemens CARE Dose 4D
-
(in press)
-
Söderberg M, Gunnarsson M. The effect of different adaptation strengths on image quality and radiation dose using Siemens CARE Dose 4D. Radiat Prot Dosimetry 2010 (in press).
-
(2010)
Radiat Prot Dosimetry
-
-
Söderberg, M.1
Gunnarsson, M.2
-
22
-
-
23044432016
-
Reducing radiation dose in emergency computed tomography with automatic exposure control techniques
-
Kalra MK, Rizzo SM, Novelline RA. Reducing radiation dose in emergency computed tomography with automatic exposure control techniques. Emerg Radiol 2005;11: 267-274
-
(2005)
Emerg Radiol
, vol.11
, pp. 267-274
-
-
Kalra, M.K.1
Rizzo, S.M.2
Novelline, R.A.3
-
23
-
-
13244297711
-
Techniques and applications of automatic tube current modulation for CT
-
Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, et al. Techniques and applications of automatic tube current modulation for CT. Radiology 2004;233:649-657
-
(2004)
Radiology
, vol.233
, pp. 649-657
-
-
Kalra, M.K.1
Maher, M.M.2
Toth, T.L.3
Schmidt, B.4
Westerman, B.L.5
Morgan, H.T.6
-
24
-
-
23944456572
-
Computed tomography radiation dose optimization: Scanning protocols and clinical applications of automatic exposure control
-
Kalra MK, Naz N, Rizzo SM, Blake MA. Computed tomography radiation dose optimization: scanning protocols and clinical applications of automatic exposure control. Curr Probl Diagn Radiol 2005;34:171-181
-
(2005)
Curr Probl Diagn Radiol
, vol.34
, pp. 171-181
-
-
Kalra, M.K.1
Naz, N.2
Rizzo, S.M.3
-
25
-
-
33645562681
-
CT dose reduction and dose management tools: Overview of available options
-
McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. Radiographics 2006;26:503-512
-
(2006)
Radiographics
, vol.26
, pp. 503-512
-
-
McCollough, C.H.1
Bruesewitz, M.R.2
Kofler Jr., J.M.3
-
26
-
-
77953355068
-
Brochure: LightSpeed 2369740-142 (Swedish text)
-
General Electric
-
General Electric. Brochure: LightSpeed 2369740-142 (Swedish text). General Electric Company 2004;6:7-16.
-
(2004)
General Electric Company
, vol.6
, pp. 7-16
-
-
-
28
-
-
77953327250
-
SOMATOM Sensation 64 Application Guide
-
Siemens Medical Solutions, Erlangen: Siemens Medical Solutions
-
Siemens Medical Solutions. SOMATOM Sensation 64 Application Guide. Software Version syngo CT 2005A. Erlangen: Siemens Medical Solutions; 2009.
-
(2009)
Software Version Syngo CT 2005A
-
-
-
29
-
-
77953338115
-
Optimization and reduction of CT radiation exposure using Sure- Exposure control, illustrated by a thorax protocol
-
Blobel J, Mews J, de Vries H, Juran R, Rogalla P. Optimization and reduction of CT radiation exposure using Sure- Exposure control, illustrated by a thorax protocol. Toshiba Medical Systems, VISIONS 2004;6:12-15.
-
(2004)
Toshiba Medical Systems, VISIONS
, vol.6
, pp. 12-15
-
-
Blobel, J.1
Mews, J.2
De Vries, H.3
Juran, R.4
Rogalla, P.5
-
30
-
-
36849020401
-
Principles of CT: Radiation dose and image quality
-
Goldman LW. Principles of CT: radiation dose and image quality. J Nucl Med Technol 2007;35:213-225
-
(2007)
J Nucl Med Technol
, vol.35
, pp. 213-225
-
-
Goldman, L.W.1
-
31
-
-
34347385840
-
Angular online tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction
-
Papadakis AE, Perisinakis K, Damilakis J. Angular online tube current modulation in multidetector CT examinations of children and adults: the influence of different scanning parameters on dose reduction. Med Phys 2007; 34:2864-2874
-
(2007)
Med Phys
, vol.34
, pp. 2864-2874
-
-
Papadakis, A.E.1
Perisinakis, K.2
Damilakis, J.3
|