메뉴 건너뛰기




Volumn 35, Issue 4, 2007, Pages 213-225

Principles of CT: Radiation dose and image quality

Author keywords

Computed tomography; CT; CT technology; PET CT; Quality assurance; Radiation safety

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DOSIMETRY; IMAGE ENHANCEMENT; IMAGE QUALITY; IONIZATION CHAMBER; PHANTOM; RADIATION DOSE; THERMOLUMINESCENCE DOSIMETER;

EID: 36849020401     PISSN: 00914916     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnmt.106.037846     Document Type: Article
Times cited : (306)

References (18)
  • 1
    • 0020072857 scopus 로고
    • Radiation dosimetry survey of computed tomography systems from ten manufacturers
    • Shope TB, Morgan TJ, Showalter CK, et al. Radiation dosimetry survey of computed tomography systems from ten manufacturers. Br J Radiol. 1982;55:60-69.
    • (1982) Br J Radiol , vol.55 , pp. 60-69
    • Shope, T.B.1    Morgan, T.J.2    Showalter, C.K.3
  • 2
    • 0018131461 scopus 로고
    • Patient dosage in computed tomography
    • McCullough EC, Payne JT. Patient dosage in computed tomography. Radiology. 1978;129:457-463.
    • (1978) Radiology , vol.129 , pp. 457-463
    • McCullough, E.C.1    Payne, J.T.2
  • 3
    • 0017877886 scopus 로고
    • A film dosimetry system for use in computed tomography
    • Dixon RL, Ekstrand KE. A film dosimetry system for use in computed tomography. Radiology. 1978;127:255-258.
    • (1978) Radiology , vol.127 , pp. 255-258
    • Dixon, R.L.1    Ekstrand, K.E.2
  • 4
    • 0019388095 scopus 로고
    • A multisegmented ion chamber for CT scanner dosimetry
    • Moore MM, Cacak RK, Hendee WR. A multisegmented ion chamber for CT scanner dosimetry. Med Phys. 1981;8:640-645.
    • (1981) Med Phys , vol.8 , pp. 640-645
    • Moore, M.M.1    Cacak, R.K.2    Hendee, W.R.3
  • 5
    • 36849035693 scopus 로고
    • Radiation dosimetry in computed tomography
    • Gray JE, Hendee WR, eds, September 25-27, Boston, Massachusetts. Bellingham, WA: Society of Photo-Optical Instrumentation Engineers;
    • Jucius RA, Kambic GX. Radiation dosimetry in computed tomography. In: Gray JE, Hendee WR, eds. Application of Optical Instrumentation in Medicine VI: September 25-27, 1977, Boston, Massachusetts. Bellingham, WA: Society of Photo-Optical Instrumentation Engineers; 1977.
    • (1977) Application of Optical Instrumentation in Medicine VI
    • Jucius, R.A.1    Kambic, G.X.2
  • 6
    • 0018074741 scopus 로고
    • Use of a pencil-shaped ionization chamber for measurement of exposure resulting from a computed tomography scan
    • Suzuki A, Suzuki MN. Use of a pencil-shaped ionization chamber for measurement of exposure resulting from a computed tomography scan. Med Phys. 1978;5:536-539.
    • (1978) Med Phys , vol.5 , pp. 536-539
    • Suzuki, A.1    Suzuki, M.N.2
  • 7
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission x-ray computed tomography
    • Shope TB, Gagne RM, Johnson GC. A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys. 1981;8:488-495.
    • (1981) Med Phys , vol.8 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 8
    • 35148852590 scopus 로고    scopus 로고
    • Principles of CT and CT technology
    • Goldman LW. Principles of CT and CT technology. J Nucl Med Technol. 2007;35:115-128.
    • (2007) J Nucl Med Technol , vol.35 , pp. 115-128
    • Goldman, L.W.1
  • 9
    • 0032979557 scopus 로고    scopus 로고
    • Radiation dose in spiral CT: The relative effects of collimation and pitch
    • McNitt-Grat MF, Cagnon CH, Solberg TD, Chetty I. Radiation dose in spiral CT: the relative effects of collimation and pitch. Med Phys. 1999;26:409-414.
    • (1999) Med Phys , vol.26 , pp. 409-414
    • McNitt-Grat, M.F.1    Cagnon, C.H.2    Solberg, T.D.3    Chetty, I.4
  • 11
    • 0034118614 scopus 로고    scopus 로고
    • Calculation of effective dose
    • McCollough CH, Schueler BA. Calculation of effective dose. Med Phys. 2000;27:828-834.
    • (2000) Med Phys , vol.27 , pp. 828-834
    • McCollough, C.H.1    Schueler, B.A.2
  • 12
    • 0033008479 scopus 로고    scopus 로고
    • Radiation effective doses to patients undergoing abdominal CT examinations
    • Ware DE, Huda W, Mergo PJ, Litwiller AL. Radiation effective doses to patients undergoing abdominal CT examinations. Radiology. 1999;210:645-650.
    • (1999) Radiology , vol.210 , pp. 645-650
    • Ware, D.E.1    Huda, W.2    Mergo, P.J.3    Litwiller, A.L.4
  • 13
    • 0032742081 scopus 로고    scopus 로고
    • Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation, II: phantom measurements. Med Phys. 1999;26:2248-2253.
    • Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation, II: phantom measurements. Med Phys. 1999;26:2248-2253.
  • 14
    • 20644453137 scopus 로고    scopus 로고
    • X-ray imaging physics for nuclear medicine technologists part 2: X-ray interactions and image formation
    • Seibert JA, Boone JM. X-ray imaging physics for nuclear medicine technologists part 2: x-ray interactions and image formation. J Nucl Med Technol. 2005;33:3-18.
    • (2005) J Nucl Med Technol , vol.33 , pp. 3-18
    • Seibert, J.A.1    Boone, J.M.2
  • 16
    • 0017069791 scopus 로고
    • Picture quality of computed tomography
    • Hounsfield GN. Picture quality of computed tomography. AJR. 1976;127:3-9.
    • (1976) AJR , vol.127 , pp. 3-9
    • Hounsfield, G.N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.