메뉴 건너뛰기




Volumn 139, Issue 1-3, 2010, Pages 173-179

The effect of different adaptation strengths on image quality and radiation dose using Siemens care dose 4D

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BODY BURDEN; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; EQUIPMENT; EQUIPMENT DESIGN; EVALUATION; IMAGE QUALITY; INSTRUMENTATION; METHODOLOGY; RADIATION DOSE; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; THORAX RADIOGRAPHY;

EID: 77953327950     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncq098     Document Type: Article
Times cited : (37)

References (9)
  • 1
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: overview of available options
    • McCollough, C. H., Bruesewitz, M. R. and Kofler, J. M. Jr. CT dose reduction and dose management tools: overview of available options. Radiographics. 26, 503-512 (2006).
    • (2006) Radiographics , vol.26 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler J.M., Jr.3
  • 2
    • 32744470972 scopus 로고    scopus 로고
    • MHRA Evaluation Report 05016 (London, UK: Medicines and Healthcare products Regulatory Agency)
    • Keat, N. CT scanner automatic exposure control systems. MHRA Evaluation Report 05016 (London, UK: Medicines and Healthcare products Regulatory Agency) (2005).
    • (2005) CT scanner automatic exposure control systems
    • Keat, N.1
  • 3
    • 33645830709 scopus 로고    scopus 로고
    • Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
    • Rizzo, S., Kalra, M., Schmidt, B., Dalal, T., Suess, C., Flohr, T., Blake, M. and Saini, S. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. AJR Am. J. Roentgenol. 186, 673-679 (2006).
    • (2006) AJR Am. J. Roentgenol. , vol.186 , pp. 673-679
    • Rizzo, S.1    Kalra, M.2    Schmidt, B.3    Dalal, T.4    Suess, C.5    Flohr, T.6    Blake, M.7    Saini, S.8
  • 4
    • 52949134425 scopus 로고    scopus 로고
    • Automatic exposure control in pediatric and adult multidetector CTexaminations: a phantom study on dose reduction and image quality
    • Papadakis, A. E., Perisinakis, K. and Damilakis, J. Automatic exposure control in pediatric and adult multidetector CTexaminations: a phantom study on dose reduction and image quality. Med. Phys. 35, 4567-4576 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 4567-4576
    • Papadakis, A.E.1    Perisinakis, K.2    Damilakis, J.3
  • 5
    • 25144433343 scopus 로고    scopus 로고
    • Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation
    • Mulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Van Dijck, X., Mussen, E., Venstermans, C. and Termote, J. L. Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology. 237, 213-223 (2005).
    • (2005) Radiology , vol.237 , pp. 213-223
    • Mulkens, T.H.1    Bellinck, P.2    Baeyaert, M.3    Ghysen, D.4    Van Dijck, X.5    Mussen, E.6    Venstermans, C.7    Termote, J.L.8
  • 6
    • 23044432016 scopus 로고    scopus 로고
    • Reducing radiation dose in emergency computed tomography with automatic exposure control techniques
    • Kalra, M. K., Rizzo, S. M. and Novelline, R. A. Reducing radiation dose in emergency computed tomography with automatic exposure control techniques. Emerg. Radiol. 11, 267-274 (2005).
    • (2005) Emerg. Radiol. , vol.11 , pp. 267-274
    • Kalra, M.K.1    Rizzo, S.M.2    Novelline, R.A.3
  • 7
    • 77952094734 scopus 로고    scopus 로고
    • CARE Dose 4D new technique for radiation dose reduction
    • Kalra, M. K. and Brady, T. J. CARE Dose 4D new technique for radiation dose reduction. SOMATOM Sessions. 19, 28-31 (2006).
    • (2006) SOMATOM Sessions , vol.19 , pp. 28-31
    • Kalra, M.K.1    Brady, T.J.2
  • 9
    • 33746532552 scopus 로고    scopus 로고
    • The influences of tube voltage and scan direction on combined tube current modulation: a phantom study
    • Goo, H. W. and Suh, D. S. The influences of tube voltage and scan direction on combined tube current modulation: a phantom study. Pediatr. Radiol. 36, 833-840 (2006).
    • (2006) Pediatr. Radiol. , vol.36 , pp. 833-840
    • Goo, H.W.1    Suh, D.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.