Volumn 25, Issue 6, 2010, Pages 1576-1584

Accurate and less-disturbing active antiislanding method based on pll for grid-connected converters

Author keywords

Antiislanding; Grid connected converters; Inverters; Photovoltaics

Indexed keywords

ANTI-ISLANDING; EXTENSIVE SIMULATIONS; FEEDBACK SIGNAL; FREQUENCY DRIFTS; FREQUENCY SHIFT; GENERALIZED INTEGRATORS; GRID DISTURBANCE; GRID IMPEDANCE; GRID-CONNECTED; INJECTED CURRENT; INJECTED SIGNAL; INVERTER CURRENT; MATLAB /SIMULINK; ORTHOGONAL SIGNALS; PHOTOVOLTAICS; POINT OF COMMON COUPLING; SECOND ORDERS; ZERO-CROSSINGS;

EID: 77953258964     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2010.2040088     Document Type: Article
Times cited : (154)

References (40)
  • 1
    • 9244238709 scopus 로고    scopus 로고
    • Harmonic interaction between a large number of distributed power inverters and the distribution network
    • Nov.
    • J. H. R. Enslin and P. J. M. Heskes, "Harmonic interaction between a large number of distributed power inverters and the distribution network," IEEE Trans. Power Electron., vol.19, no.6, pp. 1586-1593, Nov. 2004.
    • (2004) IEEE Trans. Power Electron. , vol.19 , Issue.6 , pp. 1586-1593
    • Enslin, J.H.R.1    Heskes, P.J.M.2
  • 7
    • 0141756262 scopus 로고    scopus 로고
    • International harmonization of grid connection guidelines: Adequate requirements for the prevention of unintentional islanding
    • A. Woyte, K. D. Brabandere, D. V. Dommelen, R. Belmans, and J. Nijs, "International harmonization of grid connection guidelines: adequate requirements for the prevention of unintentional islanding," Progr. Photovoltaics, Res. Appl., vol.11, pp. 407-424, 2003.
    • (2003) Progr. Photovoltaics, Res. Appl. , vol.11 , pp. 407-424
    • Woyte, A.1    Brabandere, K.D.2    Dommelen, D.V.3    Belmans, R.4    Nijs, J.5
  • 8
    • 52349088154 scopus 로고    scopus 로고
    • Risk analysis of islanding of photovoltaic power systems within low voltage distribution networks
    • Mar., Available
    • N. Cullen, J. Thornycroft, and A. Collinson, "Risk analysis of islanding of photovoltaic power systems within low voltage distribution networks," IEA Rep. PVPS T5-08, Mar. 2002. Available: http://www.iea.pvps. org
    • (2002) IEA Rep. PVPS T5-08
    • Cullen, N.1    Thornycroft, J.2    Collinson, A.3
  • 9
    • 42249114994 scopus 로고    scopus 로고
    • An investigation on the nondetection zones of synchronous distributed generation antiislanding protection
    • Apr.
    • J. C. M. Vieira,W. Freitas, X.Wilsun, and A.Morelato, "An investigation on the nondetection zones of synchronous distributed generation antiislanding protection," IEEE Trans. Power Del., vol.23, no.2, pp. 593- 600, Apr. 2008.
    • (2008) IEEE Trans. Power Del. , vol.23 , Issue.2 , pp. 593-600
    • Vieira, J.C.M.1    Freitas, W.2    Wilsun, X.3    Morelato, A.4
  • 10
    • 37749009766 scopus 로고    scopus 로고
    • Islanding detection assessment of multi-inverter systems with active frequency drifting methods
    • Jan.
    • L. A. C. Lopes and Z. Yongzheng, "Islanding detection assessment of multi-inverter systems with active frequency drifting methods," IEEE Trans. Power Del., vol.23, no.1, pp. 480-486, Jan. 2008.
    • (2008) IEEE Trans. Power Del. , vol.23 , Issue.1 , pp. 480-486
    • Lopes, L.A.C.1    Yongzheng, Z.2
  • 11
    • 27944456766 scopus 로고    scopus 로고
    • Evaluation of islanding detection methods for photovoltaic utility-interactive power systems
    • Mar., Available
    • W. Bower and M. Ropp, "Evaluation of islanding detection methods for photovoltaic utility-interactive power systems," IEA Task V Rep. IEAPVPS, T5-09, Mar. 2002. Available: http://www.iea.pvps.org
    • (2002) IEA Task v Rep. IEAPVPS, T5-09
    • Bower, W.1    Ropp, M.2
  • 12
    • 0037348653 scopus 로고    scopus 로고
    • Automatic phaseshift method for islanding detection of grid-connected photovoltaic inverters
    • Mar.
    • H. Guo-Kiang, C. Chih-Chang, and C. Chern-Lin, "Automatic phaseshift method for islanding detection of grid-connected photovoltaic inverters," IEEE Trans. Energy Convers., vol.18, no.1, pp. 169-173, Mar. 2003.
    • (2003) IEEE Trans. Energy Convers. , vol.18 , Issue.1 , pp. 169-173
    • Guo-Kiang, H.1    Chih-Chang, C.2    Chern-Lin, C.3
  • 13
    • 4544314869 scopus 로고    scopus 로고
    • Development of a robust anti-islanding algorithm for utility interconnection of distributed fuel cell powered generation
    • Sep.
    • C. Jeraputra and P. N. Enjeti, "Development of a robust anti-islanding algorithm for utility interconnection of distributed fuel cell powered generation," IEEE Trans. Power Electron., vol.19, no.5, pp. 1163-1170, Sep. 2004.
    • (2004) IEEE Trans. Power Electron. , vol.19 , Issue.5 , pp. 1163-1170
    • Jeraputra, C.1    Enjeti, P.N.2
  • 14
    • 4544377194 scopus 로고    scopus 로고
    • Investigation of anti-islanding protection of power converter based distributed generators using frequency domain analysis
    • Sep.
    • V. John, Y. Zhihong, and A. Kolwalkar, "Investigation of anti-islanding protection of power converter based distributed generators using frequency domain analysis," IEEE Trans. Power Electron., vol.19, no.5, pp. 1177- 1183, Sep. 2004.
    • (2004) IEEE Trans. Power Electron. , vol.19 , Issue.5 , pp. 1177-1183
    • John, V.1    Zhihong, Y.2    Kolwalkar, A.3
  • 16
    • 0026765811 scopus 로고
    • Method for preventing islanding phenomenon on utility grid with a number of small scale PV systems
    • H. Kobayashi, K. Takigawa, E. Hashimoto, A. Kitamura, and H.Matsuda, "Method for preventing islanding phenomenon on utility grid with a number of small scale PV systems," in Proc. PVSC, 1991, vol.1, pp. 695-700.
    • (1991) Proc. PVSC , vol.1 , pp. 695-700
    • Kobayashi, H.1    Takigawa, K.2    Hashimoto, E.3    Kitamura, A.4    Matsuda, H.5
  • 17
    • 33244462832 scopus 로고    scopus 로고
    • Performance assessment of active frequency drifting islanding detection methods
    • Mar.
    • L. A. C. Lopes and S. Huili, "Performance assessment of active frequency drifting islanding detection methods," IEEE Trans. Energy Convers., vol.21, no.1, pp. 171-180, Mar. 2006.
    • (2006) IEEE Trans. Energy Convers. , vol.21 , Issue.1 , pp. 171-180
    • Lopes, L.A.C.1    Huili, S.2
  • 18
    • 0032632194 scopus 로고    scopus 로고
    • Prevention of islanding in grid-connected photovoltaic systems
    • M. E. Ropp, M. Begovic, and A. Rohatgi, "Prevention of islanding in grid-connected photovoltaic systems," Progr. Photovoltaics, Res. Appl., vol.7, pp. 39-59, 1999.
    • (1999) Progr. Photovoltaics, Res. Appl. , vol.7 , pp. 39-59
    • Ropp, M.E.1    Begovic, M.2    Rohatgi, A.3
  • 19
    • 0033345608 scopus 로고    scopus 로고
    • Analysis and performance assessment of the active frequency drift method of islanding prevention
    • Sep.
    • M. E. Ropp, M. Begovic, and A. Rohatgi, "Analysis and performance assessment of the active frequency drift method of islanding prevention," IEEE Trans. Energy Convers., vol.14, no.3, pp. 810-816, Sep. 1999.
    • (1999) IEEE Trans. Energy Convers. , vol.14 , Issue.3 , pp. 810-816
    • Ropp, M.E.1    Begovic, M.2    Rohatgi, A.3
  • 20
    • 0034262643 scopus 로고    scopus 로고
    • Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones
    • Sep.
    • M. E. Ropp, M. Begovic, A. Rohatgi, G. A. Kern, R. H. Bonn, Sr., and S. Gonzalez, "Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones," IEEE Trans. Energy Convers., vol.15, no.3, pp. 290-296, Sep. 2000.
    • (2000) IEEE Trans. Energy Convers. , vol.15 , Issue.3 , pp. 290-296
    • Ropp, M.E.1    Begovic, M.2    Rohatgi, A.3    Kern, G.A.4    Bonn Sr., R.H.5    Gonzalez, S.6
  • 21
    • 22744438252 scopus 로고    scopus 로고
    • Design methodology for the frequency shift method of islanding prevention and analysis of its detection capability
    • P. Sanchis, L. Marroyo, and J. Coloma, "Design methodology for the frequency shift method of islanding prevention and analysis of its detection capability," Progr. Photovoltaics, Res. Appl., vol.13, pp. 409-428, 2005.
    • (2005) Progr. Photovoltaics, Res. Appl. , vol.13 , pp. 409-428
    • Sanchis, P.1    Marroyo, L.2    Coloma, J.3
  • 22
    • 0033874966 scopus 로고    scopus 로고
    • Predicting islanding operation of grid connected PV inverters
    • G. A. Smith, P. A. Onions, and D. G. Infield, "Predicting islanding operation of grid connected PV inverters," Electr. Power Appl., IEE Proc., vol.147, pp. 1-6, 2000.
    • (2000) Electr. Power Appl., IEE Proc. , vol.147 , pp. 1-6
    • Smith, G.A.1    Onions, P.A.2    Infield, D.G.3
  • 23
    • 8744303092 scopus 로고    scopus 로고
    • A new family of active antiislanding schemes based on DQ implementation for grid-connected inverters
    • Z. Ye, L. Li, L. Garces, C. Wang, R. Zhang, M. Dame, R. Walling, and N. Miller, "A new family of active antiislanding schemes based on DQ implementation for grid-connected inverters," in Proc. PESC, 2004, vol.1, pp. 235-241.
    • (2004) Proc. PESC , vol.1 , pp. 235-241
    • Ye, Z.1    Li, L.2    Garces, L.3    Wang, C.4    Zhang, R.5    Dame, M.6    Walling, R.7    Miller, N.8
  • 24
    • 34548091002 scopus 로고    scopus 로고
    • Study and development of anti-islanding control for grid-connected inverters
    • Golden, CO, Rep. NREL/SR-560-36243, May
    • Z. Ye, R. Walling, L. Garces, R. Zhou, L. Li, T. Wang, "Study and development of anti-islanding control for grid-connected inverters," Nat. Renewable Energy Lab., Golden, CO, Rep. NREL/SR-560-36243, May 2004.
    • (2004) Nat. Renewable Energy Lab.
    • Ye, Z.1    Walling, R.2    Garces, L.3    Zhou, R.4    Li, L.5    Wang, T.6
  • 26
    • 4544365766 scopus 로고    scopus 로고
    • Evaluation of anti-islanding schemes based on nondetection zone concept
    • Sep.
    • Y. Zhihong, A. Kolwalkar, Z. Yu, D. Pengwei, andW. Reigh, "Evaluation of anti-islanding schemes based on nondetection zone concept," IEEE Trans. Power Electron., vol.19, no.5, pp. 1171-1176, Sep. 2004.
    • (2004) IEEE Trans. Power Electron. , vol.19 , Issue.5 , pp. 1171-1176
    • Zhihong, Y.1    Kolwalkar, A.2    Yu, Z.3    Pengwei, D.4    Reigh, W.5
  • 27
    • 58249125096 scopus 로고    scopus 로고
    • Sandia frequency-shift parameter selection to eliminate nondetection zones
    • Jan.
    • H. H. Zeineldin and S. Kennedy, "Sandia frequency-shift parameter selection to eliminate nondetection zones," IEEE Trans. Power Del., vol.24, no.1, pp. 486-487, Jan. 2009.
    • (2009) IEEE Trans. Power Del. , vol.24 , Issue.1 , pp. 486-487
    • Zeineldin, H.H.1    Kennedy, S.2
  • 28
    • 59749089489 scopus 로고    scopus 로고
    • A simplified control method for the grid-connected inverter with the function of islanding detection
    • Nov.
    • J. Hurng-Liahng, C.Wen-Jung, andW. Jinn-Chang, "A simplified control method for the grid-connected inverter with the function of islanding detection," IEEE Trans. Power Electron., vol.23, no.6, pp. 2775-2783, Nov. 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.6 , pp. 2775-2783
    • Hurng-Liahng, J.1    Wen-Jung, C.2    Jinn-Chang, W.3
  • 29
    • 42249113143 scopus 로고    scopus 로고
    • Islanding detection using proportional power spectral density
    • Apr.
    • Y. Jun, C. P. Diduch, and C. Liucheng, "Islanding detection using proportional power spectral density," IEEE Trans. Power Del., vol.23, no.2, pp. 776-784, Apr. 2008.
    • (2008) IEEE Trans. Power Del. , vol.23 , Issue.2 , pp. 776-784
    • Jun, Y.1    Diduch, C.P.2    Liucheng, C.3
  • 30
    • 42549109196 scopus 로고    scopus 로고
    • Overview of antiislanding algorithms for PV systems. Part II: Active methods
    • M. Francesco De, L. Marco, and D. A. Antonio, "Overview of antiislanding algorithms for PV systems. Part II: Active methods," in Proc. IPEMC, 2006, pp. 1884-1889.
    • (2006) Proc. IPEMC , pp. 1884-1889
    • De, M.F.1    Marco, L.2    Antonio, D.A.3
  • 31
    • 42549110582 scopus 로고    scopus 로고
    • Overview of anti-islanding algorithms for PV systems. Part I: Passive methods
    • M. Francesco De, L. Marco, D. A. Antonio, and P. Alberto, "Overview of anti-islanding algorithms for PV systems. Part I: Passive methods," in Proc. PEMCC, 2006, pp. 1878-1883.
    • (2006) Proc. PEMCC , pp. 1878-1883
    • De, M.F.1    Marco, L.2    Antonio, D.A.3    Alberto, P.4
  • 32
    • 48349108795 scopus 로고    scopus 로고
    • Line impedance estimation using active and reactive power variations
    • A. V. Timbus, P. Rodriguez, R. Teodorescu, and M. Ciobotaru, "Line impedance estimation using active and reactive power variations," in Proc. PESC, 2007, pp. 1273-1279.
    • (2007) Proc. PESC , pp. 1273-1279
    • Timbus, A.V.1    Rodriguez, P.2    Teodorescu, R.3    Ciobotaru, M.4
  • 33
    • 48349107290 scopus 로고    scopus 로고
    • Online grid impedance estimation for single-phase grid-connected systems using PQ variations
    • M. Ciobotaru, R. Teodorescu, P. Rodriguez, A. Timbus, and F. Blaabjerg, "Online grid impedance estimation for single-phase grid-connected systems using PQ variations," in Proc. PESC, 2007, pp. 2306-2312.
    • (2007) Proc. PESC , pp. 2306-2312
    • Ciobotaru, M.1    Teodorescu, R.2    Rodriguez, P.3    Timbus, A.4    Blaabjerg, F.5
  • 34
    • 24144468680 scopus 로고    scopus 로고
    • Implementation and test of an online embedded grid impedance estimation technique for PV inverters
    • Aug.
    • L. Asiminoaei, R. Teodorescu, F. Blaabjerg, and U. Borup, "Implementation and test of an online embedded grid impedance estimation technique for PV inverters," IEEE Trans. Ind. Electron., vol.52, no.4, pp. 1136- 1144, Aug. 2005.
    • (2005) IEEE Trans. Ind. Electron. , vol.52 , Issue.4 , pp. 1136-1144
    • Asiminoaei, L.1    Teodorescu, R.2    Blaabjerg, F.3    Borup, U.4
  • 36
    • 28444477685 scopus 로고    scopus 로고
    • A digital controlled PV-inverter with grid impedance estimation for ENS detection
    • Nov.
    • L. Asiminoaei, R. Teodorescu, F. Blaabjerg, and U. Borup, "A digital controlled PV-inverter with grid impedance estimation for ENS detection," IEEE Trans. Power Electron., vol.20, no.6, pp. 1480-1490, Nov. 2005.
    • (2005) IEEE Trans. Power Electron. , vol.20 , Issue.6 , pp. 1480-1490
    • Asiminoaei, L.1    Teodorescu, R.2    Blaabjerg, F.3    Borup, U.4
  • 37
    • 47049108343 scopus 로고    scopus 로고
    • On-line grid impedance estimation based on harmonic injection for grid-connected PV inverter
    • M. Ciobotaru, R. Teodorescu, and F. Blaabjerg, "On-line grid impedance estimation based on harmonic injection for grid-connected PV inverter," in Proc. ISIE, 2007, pp. 2437-2442.
    • (2007) Proc. ISIE , pp. 2437-2442
    • Ciobotaru, M.1    Teodorescu, R.2    Blaabjerg, F.3
  • 38
    • 49249100542 scopus 로고    scopus 로고
    • Offset rejection for PLL based synchronization in grid-connected converters
    • M. Ciobotaru, R. Teodorescu, and V. G. Agelidis, "Offset rejection for PLL based synchronization in grid-connected converters," in Proc. APEC, 2008, pp. 1611-1617.
    • (2008) Proc. APEC , pp. 1611-1617
    • Ciobotaru, M.1    Teodorescu, R.2    Agelidis, V.G.3
  • 39
    • 42449083729 scopus 로고    scopus 로고
    • A new single-phase PLL structure based on second order generalized integrator
    • M. Ciobotaru, R. Teodorescu, and F. Blaabjerg, "A new single-phase PLL structure based on second order generalized integrator," in Proc. PESC, 2006, pp. 1-6.
    • (2006) Proc. PESC , pp. 1-6
    • Ciobotaru, M.1    Teodorescu, R.2    Blaabjerg, F.3
  • 40
    • 52349092917 scopus 로고    scopus 로고
    • Accurate and lessdisturbing active anti-islanding method based on PLL for grid-connected PV inverters
    • M. Ciobotaru, V. G. Agelidis, and R. Teodorescu, "Accurate and lessdisturbing active anti-islanding method based on PLL for grid-connected PV inverters," in Proc. PESC, 2008, pp. 4569-4576.
    • (2008) Proc. PESC , pp. 4569-4576
    • Ciobotaru, M.1    Agelidis, V.G.2    Teodorescu, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.