메뉴 건너뛰기




Volumn 23, Issue 1, 2008, Pages 480-486

Islanding detection assessment of multi-inverter systems with active frequency drifting methods

Author keywords

Distributed generation (DG); Inverters; Islanding detection; Non detection zones; Photovoltaic systems

Indexed keywords

COMPUTER SIMULATION; DISTRIBUTED POWER GENERATION; ELECTRIC FREQUENCY MEASUREMENT; ELECTRIC POWER SYSTEMS;

EID: 37749009766     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2007.911188     Document Type: Article
Times cited : (150)

References (13)
  • 1
    • 4544365766 scopus 로고    scopus 로고
    • Evaluation of anti-islanding schemes based on non detection zone concept
    • Sep
    • Z. Ye, A. Kowalkar, Y. Zhang, P. Du, and R. Walling, "Evaluation of anti-islanding schemes based on non detection zone concept," IEEE Trans. Power Electron., vol. 19, no. 5, pp. 1171-1176, Sep. 2004.
    • (2004) IEEE Trans. Power Electron , vol.19 , Issue.5 , pp. 1171-1176
    • Ye, Z.1    Kowalkar, A.2    Zhang, Y.3    Du, P.4    Walling, R.5
  • 2
    • 0031370152 scopus 로고    scopus 로고
    • SunSine300: Utility interactive AC module anti-islanding test results
    • G. Kern, "SunSine300: Utility interactive AC module anti-islanding test results," in Proc. IEEE Photovoltaic Specialists Conf., 1997, pp. 1265-1268.
    • (1997) Proc. IEEE Photovoltaic Specialists Conf , pp. 1265-1268
    • Kern, G.1
  • 3
    • 0034262643 scopus 로고    scopus 로고
    • Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones
    • Sep
    • M. Ropp, M. Begovic, A. Rohatgi, G. A. Kern, R. H. Bonn, and S. Gonzalez, "Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones," IEEE Trans. Energy Convers., vol. 15, no. 3, pp. 290-296, Sep. 2000.
    • (2000) IEEE Trans. Energy Convers , vol.15 , Issue.3 , pp. 290-296
    • Ropp, M.1    Begovic, M.2    Rohatgi, A.3    Kern, G.A.4    Bonn, R.H.5    Gonzalez, S.6
  • 4
    • 37749005742 scopus 로고    scopus 로고
    • Evaluation of Islanding Detection Methods for Photovoltaic Utility-Interactive Power Systems Task V
    • Report IEA-PVPS T5-09, Mar, Online, Available
    • W. Bower and M. Ropp, Evaluation of Islanding Detection Methods for Photovoltaic Utility-Interactive Power Systems Task V, Report IEA-PVPS T5-09, Mar. 2002. [Online]. Available: http://www.iea-pvps.org/products/ download/rep5_09.pdf, 2000.
    • (2000)
    • Bower, W.1    Ropp, M.2
  • 6
    • 0037348640 scopus 로고    scopus 로고
    • Testing the islanding protection function of photovoltaic inverters
    • Mar
    • A. Woyte, R. Belmans, and J. Nijs, "Testing the islanding protection function of photovoltaic inverters," IEEE Trans. Energy Convers., vol. 18, no. 1, pp. 157-162, Mar. 2003.
    • (2003) IEEE Trans. Energy Convers , vol.18 , Issue.1 , pp. 157-162
    • Woyte, A.1    Belmans, R.2    Nijs, J.3
  • 7
    • 33244462832 scopus 로고    scopus 로고
    • Performance assessment of active frequency drifting islanding detection methods
    • Mar
    • L. A. C. Lopes and H. Sun, "Performance assessment of active frequency drifting islanding detection methods," IEEE Trans. Energy Convers. vol. 21, no. 1, pp. 171-180, Mar. 2006.
    • (2006) IEEE Trans. Energy Convers , vol.21 , Issue.1 , pp. 171-180
    • Lopes, L.A.C.1    Sun, H.2
  • 8
    • 0036948513 scopus 로고    scopus 로고
    • The development of a scaled-down simulator for distribution grids and its application for verifying interference behavior among a number of module integrated converters (MIC)
    • Y. Noda, T. Mizuno, H. Koizumi, K. Nagasaka, and K. Kurokawa, "The development of a scaled-down simulator for distribution grids and its application for verifying interference behavior among a number of module integrated converters (MIC)," in Proc. IEEE Photovoltaic Specialists Conf., 2002, pp. 1545-1548.
    • (2002) Proc. IEEE Photovoltaic Specialists Conf , pp. 1545-1548
    • Noda, Y.1    Mizuno, T.2    Koizumi, H.3    Nagasaka, K.4    Kurokawa, K.5
  • 11
    • 0003490984 scopus 로고    scopus 로고
    • Development and Testing of an Approach to Anti-Islanding in Utility-Interconnected Photovoltaic Systems Sandia National Lab Rep
    • Aug, Online, Available
    • J. Stevens, R. Bonn, J. Ginn, S. Gonzalez, and G. Kern, Development and Testing of an Approach to Anti-Islanding in Utility-Interconnected Photovoltaic Systems Sandia National Lab Rep., SAND 2000-1939, Aug. 2000. [Online]. Available: http://www.sandia.gov/pv/docs/PDF/ 0800steve.pdf.
    • (2000) SAND , vol.2000 -1939
    • Stevens, J.1    Bonn, R.2    Ginn, J.3    Gonzalez, S.4    Kern, G.5
  • 12
    • 37749014974 scopus 로고    scopus 로고
    • A simple control circuit for a three-level hysteresis current controlled voltage source inverter
    • Z.-X. Luo, Y.-Z. Zhang, and L. A. C. Lopes, "A simple control circuit for a three-level hysteresis current controlled voltage source inverter," in Proc. IEEE Int. Symp. Industrial Electronics, 2006, pp. 751-756.
    • (2006) Proc. IEEE Int. Symp. Industrial Electronics , pp. 751-756
    • Luo, Z.-X.1    Zhang, Y.-Z.2    Lopes, L.A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.