메뉴 건너뛰기




Volumn 7642, Issue , 2010, Pages

Hydrogel-based piezoresistive biochemical microsensors

Author keywords

Biochemical sensor; Glucose sensitive; pH sensitive; Piezoresistive sensor; Polyelectrolytic hydrogel; Swelling behaviour

Indexed keywords

ANALYTE CONCENTRATION; ANALYTES; AQUEOUS SOLUTIONS; BIOCHEMICAL SENSOR; BIOCOMPATIBLE POLYMER; CONTINUOUS MONITORING; FABRICATED SENSORS; GAMMA IRRADIATION; GEL SWELLING; GLUCOSE CONCENTRATION; GLUCOSE-SENSITIVE HYDROGEL; GRADUAL CHANGES; IMPLANTABLE SENSORS; MEASUREMENT PROCEDURES; ON-LINE CONTROLS; PH SENSITIVE; PHYSIOLOGICAL PH RANGE; PIEZO-RESISTIVE; PIEZORESISTIVE SENSORS; POLYELECTROLYTIC HYDROGELS; REPRODUCIBILITIES; SENSOR RESPONSE TIME; SENSOR SIGNALS; VOLUME PHASE TRANSITION;

EID: 77953234959     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.847373     Document Type: Conference Paper
Times cited : (4)

References (21)
  • 1
    • 40449109054 scopus 로고    scopus 로고
    • Electrochemical glucose biosensors
    • Wang, J., "Electrochemical glucose biosensors," Chem. Rev. 108, 814-825 (2008).
    • (2008) Chem. Rev. , vol.108 , pp. 814-825
    • Wang, J.1
  • 2
    • 33645298033 scopus 로고    scopus 로고
    • A hydrogel-based implantable micromachined transponder for wireless glucose measurement
    • Lei, M., Baldi, A., Nuxoll, E., Siegel, R. A., Ziaie, B., "A hydrogel-based implantable micromachined transponder for wireless glucose measurement," Diabetes Techn & Therap. 8, 112-122 (2006).
    • (2006) Diabetes Techn & Therap , vol.8 , pp. 112-122
    • Lei, M.1    Baldi, A.2    Nuxoll, E.3    Siegel, R.A.4    Ziaie, B.5
  • 3
    • 67349168792 scopus 로고    scopus 로고
    • Hydrogel-based microsensors for wireless chemical monitoring
    • doi: 10.1007/s10544-008-9168-5
    • Lei, M., Baldi, A., Nuxoll, E., Siegel, R. A., Ziaie, B., "Hydrogel-based microsensors for wireless chemical monitoring", Biomed Microdevices 11, 529-538 (2009), doi: 10.1007/s10544-008-9168-5.
    • (2009) Biomed Microdevices , vol.11 , pp. 529-538
    • Lei, M.1    Baldi, A.2    Nuxoll, E.3    Siegel, R.A.4    Ziaie, B.5
  • 4
    • 75549083694 scopus 로고    scopus 로고
    • Hard and soft micro- and nanofabrication: An integrated approach to hydrogel-based biosensing and drug delivery
    • Siegel, R. A., Gu, Y., Lei, M., Baldi, A., Nuxoll, E. E., Ziaie, B., "Hard and soft micro- and nanofabrication: An integrated approach to hydrogel-based biosensing and drug delivery," J. Controll. Release 141, 303-313 (2010).
    • (2010) J. Controll. Release , vol.141 , pp. 303-313
    • Siegel, R.A.1    Gu, Y.2    Lei, M.3    Baldi, A.4    Nuxoll, E.E.5    Ziaie, B.6
  • 5
    • 74149083503 scopus 로고    scopus 로고
    • Osmotic swelling pressure response of smart hydrogels suitable for chronically implantable glucose sensors
    • Lin, G., Chang, S., Hao, H., Tathireddy, P., Orthner, M., Magda, J., Solzbacher, F., "Osmotic swelling pressure response of smart hydrogels suitable for chronically implantable glucose sensors," Sens. Actuat. B 144, 332-336 (2010).
    • (2010) Sens. Actuat. B , vol.144 , pp. 332-336
    • Lin, G.1    Chang, S.2    Hao, H.3    Tathireddy, P.4    Orthner, M.5    Magda, J.6    Solzbacher, F.7
  • 6
    • 77949340761 scopus 로고    scopus 로고
    • Hydrogel based sensor arrays (2x2) with perforated piezoresistive diaphragms for metabolic monitoring (in-vitro)
    • doi: 10.1016/j.snb.2010.01.063
    • Orthner, M. P., Lin, G., Avula, M., Buetefisch, S., Magda, J., Rieth, L. W., Solzbacher, F., "Hydrogel based sensor arrays (2x2) with perforated piezoresistive diaphragms for metabolic monitoring (in-vitro) ", Sens. Actuat. B (2010), doi: 10.1016/j.snb.2010.01.063.
    • (2010) Sens. Actuat. B
    • Orthner, M.P.1    Lin, G.2    Avula, M.3    Buetefisch, S.4    Magda, J.5    Rieth, L.W.6    Solzbacher, F.7
  • 7
    • 34249800911 scopus 로고    scopus 로고
    • In vitro, in vivo and post explantation testing of glucose-detecting biosensors: Current methods and recommendations
    • Koschwanez, H. E., W. M. Reichert, W. M., "In vitro, in vivo and post explantation testing of glucose-detecting biosensors: current methods and recommendations, " Biomaterials 28, 3687-3703 (2007).
    • (2007) Biomaterials , vol.28 , pp. 3687-3703
    • Koschwanez, H.E.1    Reichert, W.M.2
  • 8
    • 77953244308 scopus 로고    scopus 로고
    • Standards of Medical Care: Correlation between A1C level and Mean Plasma Glucose Levels on Multiple Testing over 2-3 months, Table 6 and Table 7
    • American Diabetes Association
    • American Diabetes Association, "Standards of Medical Care: Correlation between A1C level and Mean Plasma Glucose Levels on Multiple Testing over 2-3 months, Table 6 and Table 7," Diabetes Care, supplement 1, 29, 51-580 (2006).
    • (2006) Diabetes Care , vol.29 , Issue.SUPPL. 1 , pp. 51-580
  • 9
    • 77953266516 scopus 로고    scopus 로고
    • Design of a self-cleaning thermoresponsive nanocomposite hydrogel membrane for implantable biosensors
    • doi: 10.1016/j.actbio.2010.01.039
    • Gant, R. M., Abraham, A. A., Hou, Y., Cummins, B. M., Grunlan, M. A., Coté, G. L., "Design of a self-cleaning thermoresponsive nanocomposite hydrogel membrane for implantable biosensors," Acta Biomaterialia (2010), doi: 10.1016/j.actbio.2010.01.039.
    • (2010) Acta Biomaterialia
    • Gant, R.M.1    Abraham, A.A.2    Hou, Y.3    Cummins, B.M.4    Grunlan, M.A.5    Coté, G.L.6
  • 10
    • 0033741867 scopus 로고    scopus 로고
    • Catalase effects on glucose-sensitive hydrogels
    • Jung, D. Y., Magda, J. J., Han, I. S., "Catalase effects on glucose-sensitive hydrogels," Macromolecules 33, 3332-3336 (2000).
    • (2000) Macromolecules , vol.33 , pp. 3332-3336
    • Jung, D.Y.1    Magda, J.J.2    Han, I.S.3
  • 11
    • 77953258327 scopus 로고    scopus 로고
    • Design, simulation and optimization of a novel piezoresistive pressure sensor with stress sensitive perforated diaphragm for wet sensing and hydrogel applications
    • Orthner, M. P., Buetefisch S., Rieth, L. W., Magda, J., and Solzbacher, F., "Design, simulation and optimization of a novel piezoresistive pressure sensor with stress sensitive perforated diaphragm for wet sensing and hydrogel applications," IEEE Sensors J., (2010).
    • (2010) IEEE Sensors J.
    • Orthner, M.P.1    Buetefisch, S.2    Rieth, L.W.3    Magda, J.4    Solzbacher, F.5
  • 12
    • 33746038131 scopus 로고    scopus 로고
    • Poly(vinyl alcohol)/poly(acrylic acid) hydrogels: FT-IR spectroscopic characterization of crosslinking reaction and work at transition point
    • Arndt, K.-F., Richter, A., Ludwig, S., Zimmermann, J., Kressler, J., Kuckling, D., Adler, H.-J., "Poly(vinyl alcohol)/poly(acrylic acid) hydrogels: FT-IR spectroscopic characterization of crosslinking reaction and work at transition point," Acta Polymerica 50, 383-390 (1999).
    • (1999) Acta Polymerica , vol.50 , pp. 383-390
    • Arndt, K.-F.1    Richter, A.2    Ludwig, S.3    Zimmermann, J.4    Kressler, J.5    Kuckling, D.6    Adler, H.-J.7
  • 13
    • 77953244846 scopus 로고    scopus 로고
    • Smart boronate-containing copolymers and gels at solid-liquid interfaces, cell, membranes, and tissues
    • Galaev, I. and Mattiasson, B. (eds), 2nd ed., CRC Press, Boca Raton, London, New York
    • Ivanov, A. E., Galaev, I. Y., Mattiasson, B., "Smart boronate-containing copolymers and gels at solid-liquid interfaces, cell, membranes, and tissues", [Smart polymers: applications in biotechnology and biomedicine], Galaev, I. and Mattiasson, B. (eds), 2nd ed., CRC Press, Boca Raton, London, New York, 299-329 (2008).
    • (2008) Smart Polymers: Applications in Biotechnology and Biomedicine , pp. 299-329
    • Ivanov, A.E.1    Galaev, I.Y.2    Mattiasson, B.3
  • 14
    • 7044263179 scopus 로고    scopus 로고
    • a, pH, and binding constants in the interactions between boronic acids and diols - It is not as simple as it appears
    • DOI 10.1016/j.tet.2004.08.051, PII S004040200401378X, Synthetic Receptors as Sensors
    • Yan, J., Springsteen, G., Deeter, S., Wang, B., "The relationship among pKa, pH, and binding constants in the interactions between boronic acids and diols - it is not as simple as it appears," Tetrahedron 60, 11205-11209 (2004). (Pubitemid 39425240)
    • (2004) Tetrahedron , vol.60 , Issue.49 , pp. 11205-11209
    • Yan, J.1    Springsteen, G.2    Deeter, S.3    Wang, B.4
  • 16
    • 69949115685 scopus 로고    scopus 로고
    • Hydrogels for chemical sensors
    • Gerlach, G., Arndt, K.-F. (eds.), Springer Series on Chemical Sensors and Biosensors, Springer, Berlin Heidelberg
    • Guenther, M., Gerlach, G., "Hydrogels for chemical sensors," [Hydrogel Sensors and Actuators], Gerlach, G., Arndt, K.-F. (eds.), Springer Series on Chemical Sensors and Biosensors, v. 6, Springer, Berlin Heidelberg, 165-195 (2009).
    • (2009) Hydrogel Sensors and Actuators , vol.6 , pp. 165-195
    • Guenther, M.1    Gerlach, G.2
  • 17
    • 77952419886 scopus 로고    scopus 로고
    • Piezoresistive biochemical sensors based on hydrogels
    • doi: 10.1007/s00542-009-0978-z
    • Guenther, M., Gerlach, G., Wallmersperger, T., "Piezoresistive biochemical sensors based on hydrogels," Microsystem Technologies (2010), doi: 10.1007/s00542-009-0978-z.
    • (2010) Microsystem Technologies
    • Guenther, M.1    Gerlach, G.2    Wallmersperger, T.3
  • 18
    • 56449106180 scopus 로고    scopus 로고
    • Coupled chemo-electro-mechanical finite element simulation of hydrogels: I. Chemical stimulation
    • Ballhause, D. and Wallmersperger, T., "Coupled chemo-electro- mechanical finite element simulation of hydrogels: I. Chemical stimulation," Smart Mater. Struct. 17, 045011 (2008).
    • (2008) Smart Mater. Struct. , vol.17 , pp. 045011
    • Ballhause, D.1    Wallmersperger, T.2
  • 19
    • 56449106180 scopus 로고    scopus 로고
    • Coupled chemo-electro-mechanical finite element simulation of hydrogels: II. Electrical stimulation
    • Wallmersperger, T. and Ballhause D., "Coupled chemo-electro- mechanical finite element simulation of hydrogels: II. Electrical stimulation," Smart Mater. Struct. 17, 045012 (2008).
    • (2008) Smart Mater. Struct. , vol.17 , pp. 045012
    • Wallmersperger, T.1    Ballhause, D.2
  • 20
    • 77953281974 scopus 로고    scopus 로고
    • Modelling and simulation of the chemo-electro-mechanical behaviour
    • Gerlach, G., Arndt, K.-F. (eds.), Springer Series on Chemical Sensors and Biosensors, Springer, Berlin Heidelberg
    • Wallmersperger, T., "Modelling and simulation of the chemo-electro-mechanical behaviour, " [Hydrogel Sensors and Actuators], Gerlach, G., Arndt, K.-F. (eds.), Springer Series on Chemical Sensors and Biosensors, Springer, Berlin Heidelberg, v. 6, 137-163 (2009).
    • (2009) Hydrogel Sensors and Actuators , vol.6 , pp. 137-163
    • Wallmersperger, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.