메뉴 건너뛰기




Volumn 144, Issue 1, 2010, Pages 332-336

Osmotic swelling pressure response of smart hydrogels suitable for chronically implantable glucose sensors

Author keywords

Glucose sensor; Hydrogel; Piezoresistive sensor; Smart material

Indexed keywords

CONCENTRATION OF; COUNTERIONS; GLUCOSE CONCENTRATION; GLUCOSE SENSING; GLUCOSE-SENSITIVE HYDROGEL; IMPLANTABLE GLUCOSE SENSOR; IN-VIVO; OSMOTIC SWELLING PRESSURE; PIEZORESISTIVE SENSORS; REVERSIBLE CROSS-LINKS; SMART GELS; SMART HYDROGELS; SMART MATERIAL; SMART MATERIALS;

EID: 74149083503     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.07.054     Document Type: Article
Times cited : (77)

References (31)
  • 2
    • 32844456162 scopus 로고    scopus 로고
    • Crosslinking of phenylboronic acid receptors as a means of glucose selective holographic detection
    • Horgan A.M., Marshall A.J., Kew S.J., Dean K.E.S., Creasey C.D., and Kabilan S. Crosslinking of phenylboronic acid receptors as a means of glucose selective holographic detection. Biosens. Bioelectron. 21 (2006) 1838-1845
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1838-1845
    • Horgan, A.M.1    Marshall, A.J.2    Kew, S.J.3    Dean, K.E.S.4    Creasey, C.D.5    Kabilan, S.6
  • 4
    • 33751336377 scopus 로고    scopus 로고
    • Designed boronate ligands for glucose-selective holographic sensors
    • Yang X., Lee M.-C., Sartain F., Pan X., and Lowe C.R. Designed boronate ligands for glucose-selective holographic sensors. Chem. Eur. J. 12 (2006) 8491-8497
    • (2006) Chem. Eur. J. , vol.12 , pp. 8491-8497
    • Yang, X.1    Lee, M.-C.2    Sartain, F.3    Pan, X.4    Lowe, C.R.5
  • 5
    • 37349032166 scopus 로고    scopus 로고
    • Towards the real-time monitoring of glucose in tear fluid: holographic glucose sensors with reduced interference from lactate and pH
    • Yang X., Pan X., Blyth J., and Lowe C.R. Towards the real-time monitoring of glucose in tear fluid: holographic glucose sensors with reduced interference from lactate and pH. Biosens. Bioelect. 23 (2008) 899-905
    • (2008) Biosens. Bioelect. , vol.23 , pp. 899-905
    • Yang, X.1    Pan, X.2    Blyth, J.3    Lowe, C.R.4
  • 7
    • 60349103081 scopus 로고    scopus 로고
    • Glucose sensors based on a responsive gel incorporated as a Fabry-Perot cavity on a fiber-optic readout platform
    • Tierney S., Volden S., and Stokke B.T. Glucose sensors based on a responsive gel incorporated as a Fabry-Perot cavity on a fiber-optic readout platform. Biosens. Bioelectron. 24 (2009) 2034-2039
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 2034-2039
    • Tierney, S.1    Volden, S.2    Stokke, B.T.3
  • 8
    • 66149130308 scopus 로고    scopus 로고
    • Determination of glucose levels using a functionalized hydrogel-optical fiber biosensor: toward continuous monitoring of blood glucose in vivo
    • Tierney S., Falch B.M.H., Hjelme D.R., and Stokke B.T. Determination of glucose levels using a functionalized hydrogel-optical fiber biosensor: toward continuous monitoring of blood glucose in vivo. Anal. Chem. 81 (2009) 3630-3636
    • (2009) Anal. Chem. , vol.81 , pp. 3630-3636
    • Tierney, S.1    Falch, B.M.H.2    Hjelme, D.R.3    Stokke, B.T.4
  • 9
    • 0007245137 scopus 로고
    • Synthesis, equilibrium swelling, kinetics, permeability and applications of environmentally responsive gels
    • Gehrke S.H. Synthesis, equilibrium swelling, kinetics, permeability and applications of environmentally responsive gels. Adv. Polym. Sci. 110 (1993) 81-144
    • (1993) Adv. Polym. Sci. , vol.110 , pp. 81-144
    • Gehrke, S.H.1
  • 10
    • 0033178588 scopus 로고    scopus 로고
    • Smart polymers and what they could do in biotechnology and medicine
    • Galaev I.Y., and Mattiasson B. Smart polymers and what they could do in biotechnology and medicine. Trends Biotechnol. 17 (1999) 335-340
    • (1999) Trends Biotechnol. , vol.17 , pp. 335-340
    • Galaev, I.Y.1    Mattiasson, B.2
  • 11
    • 34249800911 scopus 로고    scopus 로고
    • In vitro, in vivo and post explanation testing of glucose-detecting biosensors: current methods and recommendations
    • Koschwanez H.E., and Reichert W.M. In vitro, in vivo and post explanation testing of glucose-detecting biosensors: current methods and recommendations. Biomaterials 28 (2007) 3687-3703
    • (2007) Biomaterials , vol.28 , pp. 3687-3703
    • Koschwanez, H.E.1    Reichert, W.M.2
  • 13
    • 84994986376 scopus 로고
    • Effect of the incorporation of amino groups in a glucose-responsive polymer complex having phenylboronic acid moieties
    • Kitano S., Hisamitsu I., Koyama Y., Kataoka K., Okano T., and Sakurai Y. Effect of the incorporation of amino groups in a glucose-responsive polymer complex having phenylboronic acid moieties. Polym. Adv. Technol. 2 (1991) 261-264
    • (1991) Polym. Adv. Technol. , vol.2 , pp. 261-264
    • Kitano, S.1    Hisamitsu, I.2    Koyama, Y.3    Kataoka, K.4    Okano, T.5    Sakurai, Y.6
  • 14
    • 0000973041 scopus 로고
    • Glucose-responsive complex formation between poly(vinyl alcohol) and poly(N-vinyl-2-pyrrolidone) with pendent phenylboronic acid moieties
    • Kitano S., Kataoka K., Koyama Y., Okano T., and Sakurai Y. Glucose-responsive complex formation between poly(vinyl alcohol) and poly(N-vinyl-2-pyrrolidone) with pendent phenylboronic acid moieties. Makromol. Chem. Rapid Commun. 12 (1991) 227-233
    • (1991) Makromol. Chem. Rapid Commun. , vol.12 , pp. 227-233
    • Kitano, S.1    Kataoka, K.2    Koyama, Y.3    Okano, T.4    Sakurai, Y.5
  • 15
    • 0028380817 scopus 로고
    • Sensitive glucose-induced change of the lower critical solution temperature of poly[N,N-dimethylacrylamide-co-3-(acrylamido)phenylboronic acid] in physiological Saline
    • Kataoka K., Miyazaki H., Okano T., and Sakurai Y. Sensitive glucose-induced change of the lower critical solution temperature of poly[N,N-dimethylacrylamide-co-3-(acrylamido)phenylboronic acid] in physiological Saline. Macromolecules 27 (1994) 1061-1062
    • (1994) Macromolecules , vol.27 , pp. 1061-1062
    • Kataoka, K.1    Miyazaki, H.2    Okano, T.3    Sakurai, Y.4
  • 16
    • 0032501420 scopus 로고    scopus 로고
    • Totally synthetic polymer gels responding to external glucose concentration: their preparation and application in on-off regulation of insulin release
    • Kataoka K., Miyazaki H., Bunya M., Okano T., and Sakurai Y. Totally synthetic polymer gels responding to external glucose concentration: their preparation and application in on-off regulation of insulin release. J. Am. Chem. Soc. 120 (1998) 12694-12695
    • (1998) J. Am. Chem. Soc. , vol.120 , pp. 12694-12695
    • Kataoka, K.1    Miyazaki, H.2    Bunya, M.3    Okano, T.4    Sakurai, Y.5
  • 17
    • 0033978399 scopus 로고    scopus 로고
    • A membrane-moderated conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions
    • Arnold F.H., Zheng W., and Michaels A.S. A membrane-moderated conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions. J. Membr. Sci. 167 (2000) 227-239
    • (2000) J. Membr. Sci. , vol.167 , pp. 227-239
    • Arnold, F.H.1    Zheng, W.2    Michaels, A.S.3
  • 18
    • 3042568875 scopus 로고    scopus 로고
    • Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens
    • Badugu R., Lakowicz J.R., and Geddes C.D. Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens. Analyst 129 (2001) 516-521
    • (2001) Analyst , vol.129 , pp. 516-521
    • Badugu, R.1    Lakowicz, J.R.2    Geddes, C.D.3
  • 19
    • 0036193231 scopus 로고    scopus 로고
    • A hydrogel-actuated smart microvalve with a porous diffusion barrier back-plate for active flow control
    • Las Vegas, NV
    • Baldi A., Gu Y., Loftness P.E., Siegel R.A., and Ziaie B. A hydrogel-actuated smart microvalve with a porous diffusion barrier back-plate for active flow control. Proc. IEEE Intl. Conference on MEMS, Jan 20-24. Las Vegas, NV (2002) 105-107
    • (2002) Proc. IEEE Intl. Conference on MEMS, Jan 20-24 , pp. 105-107
    • Baldi, A.1    Gu, Y.2    Loftness, P.E.3    Siegel, R.A.4    Ziaie, B.5
  • 20
    • 0000316996 scopus 로고    scopus 로고
    • Artificial receptors as chemosensors for carbohydrates
    • James T.D., and Shinkai S. Artificial receptors as chemosensors for carbohydrates. Top. Curr. Chem. 218 (2002) 159-200
    • (2002) Top. Curr. Chem. , vol.218 , pp. 159-200
    • James, T.D.1    Shinkai, S.2
  • 21
    • 2342426340 scopus 로고    scopus 로고
    • Glucose-sensitive inverse opal hydrogels: analysis of optical diffraction response
    • Lee Y.-J., Pruzinsky S.A., and Braun P.V. Glucose-sensitive inverse opal hydrogels: analysis of optical diffraction response. Langmuir 20 (2004) 3096-3106
    • (2004) Langmuir , vol.20 , pp. 3096-3106
    • Lee, Y.-J.1    Pruzinsky, S.A.2    Braun, P.V.3
  • 23
    • 74149093056 scopus 로고    scopus 로고
    • Ph.D. Thesis, University of Minnesota
    • Y. Gu, Ph.D. Thesis, University of Minnesota, 2003.
    • (2003)
    • Gu, Y.1
  • 24
    • 0036479751 scopus 로고    scopus 로고
    • Increased fructose concentrations in blood and urine in patients with diabetes
    • Kawasaki T.H., Akanuma H., and Yamanouchi T. Increased fructose concentrations in blood and urine in patients with diabetes. Diabetes Care 25 (2002) 353-357
    • (2002) Diabetes Care , vol.25 , pp. 353-357
    • Kawasaki, T.H.1    Akanuma, H.2    Yamanouchi, T.3
  • 25
    • 74149094160 scopus 로고    scopus 로고
    • Ph.D. Thesis, University of Minnesota
    • S.K. Mujumdar, Ph.D. Thesis, University of Minnesota, 2008.
    • (2008)
    • Mujumdar, S.K.1
  • 27
    • 0002224121 scopus 로고
    • Structure and elasticity of non-crystalline polymer networks
    • Dusek K., and Prins W. Structure and elasticity of non-crystalline polymer networks. Adv. Polym. Sci. 6 (1969) 1-102
    • (1969) Adv. Polym. Sci. , vol.6 , pp. 1-102
    • Dusek, K.1    Prins, W.2
  • 28
    • 58249140795 scopus 로고    scopus 로고
    • Free swelling and confined smart hydrogels for applications in chemomechanical sensors for physiological monitoring
    • Lin G., Chang S., Kuo C.-H., Magda J., and Solzbacher F. Free swelling and confined smart hydrogels for applications in chemomechanical sensors for physiological monitoring. Sens. Actuators B: Chem. 136 (2009) 186-195
    • (2009) Sens. Actuators B: Chem. , vol.136 , pp. 186-195
    • Lin, G.1    Chang, S.2    Kuo, C.-H.3    Magda, J.4    Solzbacher, F.5
  • 29
    • 33645298033 scopus 로고    scopus 로고
    • A hydrogel-based implantable micromachined transponder for wireless glucose measurement
    • Lei M., Baldi A., Nuxoll E., Siegel R.A., and Ziaie B. A hydrogel-based implantable micromachined transponder for wireless glucose measurement. Diabetes Technol. Ther. 8 (2006) 112-122
    • (2006) Diabetes Technol. Ther. , vol.8 , pp. 112-122
    • Lei, M.1    Baldi, A.2    Nuxoll, E.3    Siegel, R.A.4    Ziaie, B.5
  • 30
    • 0035021705 scopus 로고    scopus 로고
    • Sensors for glucose monitoring: technical and clinical aspects
    • Koschinsky T., and Heinemann L. Sensors for glucose monitoring: technical and clinical aspects. Diabetes Metab. Res. Rev. 17 (2001) 113-123
    • (2001) Diabetes Metab. Res. Rev. , vol.17 , pp. 113-123
    • Koschinsky, T.1    Heinemann, L.2
  • 31
    • 67649385565 scopus 로고    scopus 로고
    • A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymer
    • Huang X., Li S., Schultz J.S., Wang Q., and Lin Q. A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymer. Sens. Actuators B: Chem. 140 (2009) 603-609
    • (2009) Sens. Actuators B: Chem. , vol.140 , pp. 603-609
    • Huang, X.1    Li, S.2    Schultz, J.S.3    Wang, Q.4    Lin, Q.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.