메뉴 건너뛰기




Volumn 14, Issue 3, 2010, Pages 681-690

Local hemodynamics and intimal hyperplasia at the venous side of a porcine arteriovenous shunt

Author keywords

Arteriovenous shunt; Computational fluid dynamics; Doppler ultrasound; Hemodynamics; Intimal hyperplasia; Swine model

Indexed keywords

ARTERIOVENOUS SHUNT; BIPLANE ANGIOGRAPHIES; COLOR DOPPLER; COMPUTATIONAL MODEL; DEAN VORTEX; DOPPLER ULTRASOUND; EXPERIMENTAL DATA; IN-VIVO; IN-VIVO EXPERIMENTS; INPUT DATAS; INTIMAL HYPERPLASIA; INTRAVASCULAR; MECHANICAL STUDY; TRANSITION LINES; ULTRASOUND MEASUREMENT; VESSEL WALLS; WALL MECHANICS; WALL SHEAR STRESS; WSS GRADIENTS;

EID: 77953167779     PISSN: 10897771     EISSN: None     Source Type: Journal    
DOI: 10.1109/TITB.2010.2040288     Document Type: Article
Times cited : (29)

References (26)
  • 2
    • 0028969677 scopus 로고
    • Dialysis access grafts: Anatomic location of venous stenosis and results of angioplasty
    • R. Y. Kanterman, T. M. Vesely, T. K. Pilgram, B. W. Guy, D. W. Windus, andD. Picus, "Dialysis access grafts: Anatomic location of venous stenosis and results of angioplasty," Radiology, vol.195, pp. 135-139, 1995.
    • (1995) Radiology , vol.195 , pp. 135-139
    • Kanterman, R.Y.1    Vesely, T.M.2    Pilgram, T.K.3    Guy, B.W.4    Windus, D.W.5    Picus, D.6
  • 5
    • 0029415075 scopus 로고
    • Anastomotic intimal hyperplasia in prosthetic arteriovenous fistulas for hemodialysis is associated with initial high flow velocity and not with mismatch in elastic properties
    • L. Hofstra, D. C. Bergmans, K. M. Leunissen, A. P. Hoeks, P. J. Kitslaar, M. J. Daemen, and J. H. Tordoir, "Anastomotic intimal hyperplasia in prosthetic arteriovenous fistulas for hemodialysis is associated with initial high flow velocity and not with mismatch in elastic properties," J. Am. Soc. Nephrol., vol.6, pp. 1625-1633, 1995.
    • (1995) J. Am. Soc. Nephrol. , vol.6 , pp. 1625-1633
    • Hofstra, L.1    Bergmans, D.C.2    Leunissen, K.M.3    Hoeks, A.P.4    Kitslaar, P.J.5    Daemen, M.J.6    Tordoir, J.H.7
  • 6
    • 0033806855 scopus 로고    scopus 로고
    • Computational haemodynamics analysis and comparison study of arteriovenous grafts
    • P.W. Longest and C. Kleinstreuer, "Computational haemodynamics analysis and comparison study of arteriovenous grafts," J. Med. Eng. Technol., vol.24, pp. 102-110, 2000.
    • (2000) J. Med. Eng. Technol. , vol.24 , pp. 102-110
    • Longest, P.W.1    Kleinstreuer, C.2
  • 7
    • 0026131353 scopus 로고
    • Haemodynamics of angioaccess venous anastomoses
    • M. C. Shu and H. Hwang, "Haemodynamics of angioaccess venous anastomoses," J. Biomed. Eng., vol.13, pp. 103-112, 1991.
    • (1991) J. Biomed. Eng. , vol.13 , pp. 103-112
    • Shu, M.C.1    Hwang, H.2
  • 9
    • 0346158211 scopus 로고    scopus 로고
    • Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: A review
    • H. Haruguchi and S. Teraoka, "Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: A review," J. Artif. Organs, vol.6, pp. 227-235, 2003.
    • (2003) J. Artif. Organs , vol.6 , pp. 227-235
    • Haruguchi, H.1    Teraoka, S.2
  • 10
    • 33645468474 scopus 로고    scopus 로고
    • Hemodialysis vascular access dysfunction: A cellular and molecular viewpoint
    • P. Roy-Chaundhury, V. P. Sukhatme, and A. K. Cheung, "Hemodialysis vascular access dysfunction: A cellular and molecular viewpoint," J. Amer. Soc. Nephrol., vol.17, pp. 1112-1127, 2006.
    • (2006) J. Amer. Soc. Nephrol. , vol.17 , pp. 1112-1127
    • Roy-Chaundhury, P.1    Sukhatme, V.P.2    Cheung, A.K.3
  • 11
    • 0000767664 scopus 로고    scopus 로고
    • A new near-wall residence time model applied to three arteriovenous graft end-to-side anastomoses
    • P.W. Longest, C. Kleinstreuer, and J. R. Buchanan, "A new near-wall residence time model applied to three arteriovenous graft end-to-side anastomoses," Comput. Methods Biomech. Biomed. Eng., vol.4, pp. 379-397, 2001.
    • (2001) Comput. Methods Biomech. Biomed. Eng. , vol.4 , pp. 379-397
    • Longest, P.W.1    Kleinstreuer, C.2    Buchanan, J.R.3
  • 12
    • 0035985044 scopus 로고    scopus 로고
    • Computational fluid dynamics and vascular access
    • U. Krueger, J. Zanow, and H. Scholz, "Computational fluid dynamics and vascular access," Artif. Organs, vol.26, pp. 571-575, 2002.
    • (2002) Artif. Organs , vol.26 , pp. 571-575
    • Krueger, U.1    Zanow, J.2    Scholz, H.3
  • 13
    • 0033758652 scopus 로고    scopus 로고
    • Comparison of two different arteriovenous anastomotic forms by numerical 3D simulation of blood flow
    • U. Krueger, J. Zanow, and H. Scholz, "Comparison of two different arteriovenous anastomotic forms by numerical 3D simulation of blood flow," Int. J. Angiol., vol.9, pp. 226-231, 2000.
    • (2000) Int. J. Angiol. , vol.9 , pp. 226-231
    • Krueger, U.1    Zanow, J.2    Scholz, H.3
  • 14
    • 28444487454 scopus 로고    scopus 로고
    • Comparison of the hemodynamics in 6 mm and 4-7 mm hemodialysis grafts by means of CFD
    • I. Van Tricht, D. De Wachter, J. Tordoir, and P. Verdonck, "Comparison of the hemodynamics in 6 mm and 4-7 mm hemodialysis grafts by means of CFD," J. Biomech., vol.39, pp. 226-236, 2006.
    • (2006) J. Biomech. , vol.39 , pp. 226-236
    • Van Tricht, I.1    De Wachter, D.2    Tordoir, J.3    Verdonck, P.4
  • 15
    • 0037291819 scopus 로고    scopus 로고
    • Transitional flow at the venous anastomosis of an arteriovenous graft: Potential activation of the ERK1/2 mechanotransduction pathway
    • F. Loth, P. F. Fisher, N. Arslan, C. D. Bertram, S. E. Lee, T. J. Royston, W. E. Shaalan, and H. S. Bassiouny, "Transitional flow at the venous anastomosis of an arteriovenous graft: Potential activation of the ERK1/2 mechanotransduction pathway," J. Biomech. Eng., vol.125, pp. 49-61, 2003.
    • (2003) J. Biomech. Eng. , vol.125 , pp. 49-61
    • Loth, F.1    Fisher, P.F.2    Arslan, N.3    Bertram, C.D.4    Lee, S.E.5    Royston, T.J.6    Shaalan, W.E.7    Bassiouny, H.S.8
  • 17
    • 0036182407 scopus 로고    scopus 로고
    • Relative contribution of wall shear stress and injury in experimental intimal thickening at PTFE end-to-side arterial anastomoses
    • F. Loth, S. A. Jones, C. K. Zarins, D. P. Giddens, R. F. Nassar, S. Glagov, and H. S. Bassiouny, "Relative contribution of wall shear stress and injury in experimental intimal thickening at PTFE end-to-side arterial anastomoses," J. Biomech. Eng., vol.124, pp. 44-51, 2002.
    • (2002) J. Biomech. Eng. , vol.124 , pp. 44-51
    • Loth, F.1    Jones, S.A.2    Zarins, C.K.3    Giddens, D.P.4    Nassar, R.F.5    Glagov, S.6    Bassiouny, H.S.7
  • 20
    • 0037286091 scopus 로고    scopus 로고
    • Evaluation of 4-mm to 7-mm versus 6-mm prosthetic brachial-antecubital forearm loop access for hemodialysis: Results of a randomized multicenter clinical trial
    • R.Dammers, R.N. Planken,K.P.Pouls,R. J.VanDet,H.Burger, F.M.Van Der Sande, and J. H. Tordoir, "Evaluation of 4-mm to 7-mm versus 6-mm prosthetic brachial-antecubital forearm loop access for hemodialysis: Results of a randomized multicenter clinical trial," J. Vasc. Surg., vol.37, pp. 143-148, 2003.
    • (2003) J. Vasc. Surg. , vol.37 , pp. 143-148
    • Dammers, R.1    Planken, R.N.2    Pouls, K.P.3    Van Det, R.J.4    Burger, H.5    Van Der Sande, F.M.6    Tordoir, J.H.7
  • 21
    • 0031149182 scopus 로고    scopus 로고
    • Measurements of velocity and wall shear stress inside a PTFE vascular graft model under steady flow conditions
    • F. Loth, S. A. Jones, G. P. Giddens, H. S. Bassiouny, S. Glagov, and C. K. Zarins, "Measurements of velocity and wall shear stress inside a PTFE vascular graft model under steady flow conditions," J. Biomech. Eng., vol.119, pp. 187-194, 1997.
    • (1997) J. Biomech. Eng. , vol.119 , pp. 187-194
    • Loth, F.1    Jones, S.A.2    Giddens, G.P.3    Bassiouny, H.S.4    Glagov, S.5    Zarins, C.K.6
  • 22
    • 0037304822 scopus 로고    scopus 로고
    • Biomechanical response of femoral vein to chronic elevation of blood pressure in rabbits
    • K. Hayashi, K. Mori, and H. Miyazaki, "Biomechanical response of femoral vein to chronic elevation of blood pressure in rabbits," Amer. J. Physiol. Heart Circ. Physiol., vol.284, pp. H511-H518, 2003.
    • (2003) Amer. J. Physiol. Heart Circ. Physiol. , vol.284
    • Hayashi, K.1    Mori, K.2    Miyazaki, H.3
  • 23
    • 0034795314 scopus 로고    scopus 로고
    • Influence of long-term experimental orthostatic body position on innervation density in extremity vessels
    • E. Monos, M. Lorant, and E. Feher, "Influence of long-term experimental orthostatic body position on innervation density in extremity vessels," Amer. J. Physiol. Heart Circ. Physiol., vol.281, pp. H1606-H1612, 2001.
    • (2001) Amer. J. Physiol. Heart Circ. Physiol. , vol.281
    • Monos, E.1    Lorant, M.2    Feher, E.3
  • 25
    • 0019223445 scopus 로고
    • Does hemodynamic adaptation take place in the vein grafted into an artery?
    • E. Monos and J. Csengody, "Does hemodynamic adaptation take place in the vein grafted into an artery?," Pflügers Arch., vol.384, pp. 177-182, 1980.
    • (1980) Pflügers Arch. , vol.384 , pp. 177-182
    • Monos, E.1    Csengody, J.2
  • 26
    • 0016826483 scopus 로고
    • Static linear and nonlinear elastic properties of normal and arterialized venous tissue in dog and man
    • R. L. R. Wesley, R. N. Vaishnav, J. C. A. Fuchs, D. J. Patel, and J. C. Greenfield, Jr., "Static linear and nonlinear elastic properties of normal and arterialized venous tissue in dog and man," Circ. Res., vol.37, pp. 509-520, 1975.
    • (1975) Circ. Res. , vol.37 , pp. 509-520
    • Wesley, R.L.R.1    Vaishnav, R.N.2    Fuchs, J.C.A.3    Patel, D.J.4    Greenfield Jr., J.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.