-
1
-
-
62949176531
-
Upper extremity regional anesthesia: Essentials of our current understanding, 2008
-
Neal JM, Gerancher JC, Hebl JR, Ilfeld BM, McCartney CJ, Franco CD, Hogan QH. Upper extremity regional anesthesia: essentials of our current understanding, 2008. Reg Anesth Pain Med 2009 34 : 134 170.
-
(2009)
Reg Anesth Pain Med
, vol.34
, pp. 134-170
-
-
Neal, J.M.1
Gerancher, J.C.2
Hebl, J.R.3
Ilfeld, B.M.4
McCartney, C.J.5
Franco, C.D.6
Hogan, Q.H.7
-
3
-
-
0021205264
-
Electrical nerve location: Numerical and electrophoretic comparison of insulated vs uninsulated needles
-
Bashein G, Haschke RH, Ready LB. Electrical nerve location: numerical and electrophoretic comparison of insulated vs uninsulated needles. Anesth Analg 1984 63 : 919 924.
-
(1984)
Anesth Analg
, vol.63
, pp. 919-924
-
-
Bashein, G.1
Haschke, R.H.2
Ready, L.B.3
-
4
-
-
2542449139
-
Peripheral nerve stimulators: Cracking the code - One at a time
-
Hadzic A. Peripheral nerve stimulators: cracking the code - one at a time. Reg Anesth Pain Med 2004 29 : 185 188.
-
(2004)
Reg Anesth Pain Med
, vol.29
, pp. 185-188
-
-
Hadzic, A.1
-
5
-
-
70349744060
-
High or low current threshold for nerve stimulation for regional anaesthesia
-
Steinfeldt T, Graf J, Vassiliou T, Morin A, Feldmann K, Nimphius W, De Andres J, Wulf H. High or low current threshold for nerve stimulation for regional anaesthesia. Acta Anaesthesiol Scand 2009 53 : 1275 1281.
-
(2009)
Acta Anaesthesiol Scand
, vol.53
, pp. 1275-1281
-
-
Steinfeldt, T.1
Graf, J.2
Vassiliou, T.3
Morin, A.4
Feldmann, K.5
Nimphius, W.6
De Andres, J.7
Wulf, H.8
-
6
-
-
0033971021
-
1,001 subclavian perivascular brachial plexus blocks: Success with a nerve stimulator
-
Franco CD, Vieira ZE. 1,001 subclavian perivascular brachial plexus blocks: success with a nerve stimulator. Reg Anesth Pain Med 2000 25 : 41 6.
-
(2000)
Reg Anesth Pain Med
, vol.25
, pp. 41-46
-
-
Franco, C.D.1
Vieira, Z.E.2
-
7
-
-
84988074836
-
Refining binominal confidence intervals
-
Casella G. Refining binominal confidence intervals. Can J Statist 1986 14 : 113 129.
-
(1986)
Can J Statist
, vol.14
, pp. 113-129
-
-
Casella, G.1
-
8
-
-
34548126510
-
Ultrasound-guided interscalene needle placement produces successful anesthesia regardless of motor stimulation above or below 0.5 mA
-
Sinha SK, Abrams JH, Weller RS. Ultrasound-guided interscalene needle placement produces successful anesthesia regardless of motor stimulation above or below 0.5 mA. Anesth Analg 2007 105 : 848 852.
-
(2007)
Anesth Analg
, vol.105
, pp. 848-852
-
-
Sinha, S.K.1
Abrams, J.H.2
Weller, R.S.3
-
9
-
-
33748094264
-
The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound
-
Perlas A, Niazi A, McCartney C, Chan V, Xu D, Abbas S. The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound. Reg Anesth Pain Med 2006 31 : 445 450.
-
(2006)
Reg Anesth Pain Med
, vol.31
, pp. 445-450
-
-
Perlas, A.1
Niazi, A.2
McCartney, C.3
Chan, V.4
Xu, D.5
Abbas, S.6
-
10
-
-
34447345941
-
Ultrasound controlled nerve stimulation in the elbow region: High currents and short distances needed to obtain motor responses
-
Sauter AR, Dodgson MS, Stubhaug A, Cvancarova M, Klaastad O. Ultrasound controlled nerve stimulation in the elbow region: high currents and short distances needed to obtain motor responses. Acta Anaesthesiol Scand 2007 51 : 942 948.
-
(2007)
Acta Anaesthesiol Scand
, vol.51
, pp. 942-948
-
-
Sauter, A.R.1
Dodgson, M.S.2
Stubhaug, A.3
Cvancarova, M.4
Klaastad, O.5
-
11
-
-
23844505673
-
Use of a stimulating catheter for total knee replacement surgery: Preliminary results
-
Jack NT, Liem EB, Vonhogen LH. Use of a stimulating catheter for total knee replacement surgery: preliminary results. Br J Anaesth 2005 95 : 250 254.
-
(2005)
Br J Anaesth
, vol.95
, pp. 250-254
-
-
Jack, N.T.1
Liem, E.B.2
Vonhogen, L.H.3
-
12
-
-
70350138021
-
Comparison of 3 intensities of stimulation threshold for brachial plexus blocks at the midhumeral level: A prospective, double-blind, randomized study
-
Cuvillon P, Dion N, Deleuze M, Nouvellon E, Mahamat A, L'Hermite J, Boisson C, Vialles N, Ripart J, de La Coussaye JE. Comparison of 3 intensities of stimulation threshold for brachial plexus blocks at the midhumeral level: A prospective, double-blind, randomized study. Reg Anesth Pain Med 2009 34 : 296 300.
-
(2009)
Reg Anesth Pain Med
, vol.34
, pp. 296-300
-
-
Cuvillon, P.1
Dion, N.2
Deleuze, M.3
Nouvellon, E.4
Mahamat, A.5
L'Hermite, J.6
Boisson, C.7
Vialles, N.8
Ripart, J.9
De La Coussaye, J.E.10
-
13
-
-
34247513349
-
An ultrasonographic and histological study of intraneural injection and electrical stimulation in pigs
-
Chan VW, Brull R, McCartney CJ, Xu D, Abbas S, Shannon P. An ultrasonographic and histological study of intraneural injection and electrical stimulation in pigs. Anesth Analg 2007 104 : 1281 1284.
-
(2007)
Anesth Analg
, vol.104
, pp. 1281-1284
-
-
Chan, V.W.1
Brull, R.2
McCartney, C.J.3
Xu, D.4
Abbas, S.5
Shannon, P.6
-
14
-
-
42149086697
-
Intensity of the stimulating current may not be a reliable indicator of intraneural needle placement
-
Tsai TP, Vuckovic I, Dilberovic F, Obhodzas M, Kapur E, Divanovic KA, Hadzic A. Intensity of the stimulating current may not be a reliable indicator of intraneural needle placement. Reg Anesth Pain Med 2008 33 : 207 210.
-
(2008)
Reg Anesth Pain Med
, vol.33
, pp. 207-210
-
-
Tsai, T.P.1
Vuckovic, I.2
Dilberovic, F.3
Obhodzas, M.4
Kapur, E.5
Divanovic, K.A.6
Hadzic, A.7
|