메뉴 건너뛰기




Volumn 53, Issue 10, 2009, Pages 1275-1281

High or low current threshold for nerve stimulation for regional anaesthesia

Author keywords

[No Author keywords available]

Indexed keywords

RESIN;

EID: 70349744060     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2009.02087.x     Document Type: Article
Times cited : (17)

References (20)
  • 2
    • 0021205264 scopus 로고
    • Electrical nerve location: Numerical and electrophoretic comparison of insulated vs uninsulated needles
    • Bashein G, Haschke RH, Ready LB. Electrical nerve location: numerical and electrophoretic comparison of insulated vs uninsulated needles. Anesth Analg 1984 63 : 919 924.
    • (1984) Anesth Analg , vol.63 , pp. 919-924
    • Bashein, G.1    Haschke, R.H.2    Ready, L.B.3
  • 4
    • 0033971021 scopus 로고    scopus 로고
    • 1,001 subclavian perivascular brachial plexus blocks: Success with a nerve stimulator
    • Franco CD, Vieira ZE. 1,001 subclavian perivascular brachial plexus blocks: success with a nerve stimulator. Reg Anesth Pain Med 2000 25 : 41 6.
    • (2000) Reg Anesth Pain Med , vol.25 , pp. 41-6
    • Franco, C.D.1    Vieira, Z.E.2
  • 5
    • 2542449139 scopus 로고    scopus 로고
    • Peripheral nerve stimulators: Cracking the code - One at a time
    • Hadzic A. Peripheral nerve stimulators: cracking the code - one at a time. Reg Anesth Pain Med 2004 29 : 185 188.
    • (2004) Reg Anesth Pain Med , vol.29 , pp. 185-188
    • Hadzic, A.1
  • 6
    • 1642461546 scopus 로고    scopus 로고
    • The supraclavicular block with a nerve stimulator: To decrease or not to decrease, that is the question
    • Franco CD, Domashevich V, Voronov G, Rafizad AB, Jelev TJ. The supraclavicular block with a nerve stimulator: to decrease or not to decrease, that is the question. Anesth Analg 2004 98 : 1167 1171.
    • (2004) Anesth Analg , vol.98 , pp. 1167-1171
    • Franco, C.D.1    Domashevich, V.2    Voronov, G.3    Rafizad, A.B.4    Jelev, T.J.5
  • 7
    • 11344255473 scopus 로고    scopus 로고
    • Ultrasound guidance in regional anaesthesia
    • Marhofer P, Greher M, Kapral S. Ultrasound guidance in regional anaesthesia. Br J Anaesth 2005 94 : 7 17.
    • (2005) Br J Anaesth , vol.94 , pp. 7-17
    • Marhofer, P.1    Greher, M.2    Kapral, S.3
  • 8
    • 0021128446 scopus 로고
    • Comparison of insulated and uninsulated needles for locating peripheral nerves with a peripheral nerve stimulator
    • Ford DJ, Pither C, Raj PP. Comparison of insulated and uninsulated needles for locating peripheral nerves with a peripheral nerve stimulator. Anesth Analg 1984 63 : 925 928.
    • (1984) Anesth Analg , vol.63 , pp. 925-928
    • Ford, D.J.1    Pither, C.2    Raj, P.P.3
  • 9
    • 2542463150 scopus 로고    scopus 로고
    • Locating the target nerve and injectate spread in rabbit sciatic nerve block
    • Sung DH. Locating the target nerve and injectate spread in rabbit sciatic nerve block. Reg Anesth Pain Med 2004 29 : 194 200.
    • (2004) Reg Anesth Pain Med , vol.29 , pp. 194-200
    • Sung, D.H.1
  • 10
    • 33750868273 scopus 로고    scopus 로고
    • Ultrasound guidance in peripheral regional anesthesia: Philosophy, evidence-based medicine, and techniques
    • Sites BD, Brull R. Ultrasound guidance in peripheral regional anesthesia: philosophy, evidence-based medicine, and techniques. Curr Opin Anaesthesiol 2006 19 : 630 639.
    • (2006) Curr Opin Anaesthesiol , vol.19 , pp. 630-639
    • Sites, B.D.1    Brull, R.2
  • 12
    • 0035168289 scopus 로고    scopus 로고
    • An evaluation of the brachial plexus block at the humeral canal using a neurostimulator (1417 patients): The efficacy, safety, and predictive criteria of failure
    • Carles M, Pulcini A, Macchi P, Duflos P, Raucoules-Aime M, Grimaud D. An evaluation of the brachial plexus block at the humeral canal using a neurostimulator (1417 patients): the efficacy, safety, and predictive criteria of failure. Anesth Analg 2001 92 : 194 198.
    • (2001) Anesth Analg , vol.92 , pp. 194-198
    • Carles, M.1    Pulcini, A.2    MacChi, P.3    Duflos, P.4    Raucoules-Aime, M.5    Grimaud, D.6
  • 13
    • 23844505673 scopus 로고    scopus 로고
    • Use of a stimulating catheter for total knee replacement surgery: Preliminary results
    • Jack NT, Liem EB, Vonhogen LH. Use of a stimulating catheter for total knee replacement surgery: preliminary results. Br J Anaesth 2005 95 : 250 254.
    • (2005) Br J Anaesth , vol.95 , pp. 250-254
    • Jack, N.T.1    Liem, E.B.2    Vonhogen, L.H.3
  • 14
    • 34548126510 scopus 로고    scopus 로고
    • Ultrasound-guided interscalene needle placement produces successful anesthesia regardless of motor stimulation above or below 0.5 mA
    • Sinha SK, Abrams JH, Weller RS. Ultrasound-guided interscalene needle placement produces successful anesthesia regardless of motor stimulation above or below 0.5 mA. Anesth Analg 2007 105 : 848 852.
    • (2007) Anesth Analg , vol.105 , pp. 848-852
    • Sinha, S.K.1    Abrams, J.H.2    Weller, R.S.3
  • 15
    • 33748094264 scopus 로고    scopus 로고
    • The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound
    • Perlas A, Niazi A, McCartney C, Chan V, Xu D, Abbas S. The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound. Reg Anesth Pain Med 2006 31 : 445 450.
    • (2006) Reg Anesth Pain Med , vol.31 , pp. 445-450
    • Perlas, A.1    Niazi, A.2    McCartney, C.3    Chan, V.4    Xu, D.5    Abbas, S.6
  • 16
    • 34447345941 scopus 로고    scopus 로고
    • Ultrasound controlled nerve stimulation in the elbow region: High currents and short distances needed to obtain motor responses
    • Sauter AR, Dodgson MS, Stubhaug A, Cvancarova M, Klaastad O. Ultrasound controlled nerve stimulation in the elbow region: high currents and short distances needed to obtain motor responses. Acta Anaesthesiol Scand 2007 51 : 942 948.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 942-948
    • Sauter, A.R.1    Dodgson, M.S.2    Stubhaug, A.3    Cvancarova, M.4    Klaastad, O.5
  • 17
    • 34247513349 scopus 로고    scopus 로고
    • An ultrasonographic and histological study of intraneural injection and electrical stimulation in pigs
    • Chan VW, Brull R, McCartney CJ, Xu D, Abbas S, Shannon P. An ultrasonographic and histological study of intraneural injection and electrical stimulation in pigs. Anesth Analg 2007 104 : 1281 1284.
    • (2007) Anesth Analg , vol.104 , pp. 1281-1284
    • Chan, V.W.1    Brull, R.2    McCartney, C.J.3    Xu, D.4    Abbas, S.5    Shannon, P.6
  • 19
    • 0036094378 scopus 로고    scopus 로고
    • Dissociation of paresthesia, motor response, and success of axillary block - Another factor besides needle proximity
    • Moon JK. Dissociation of paresthesia, motor response, and success of axillary block - another factor besides needle proximity. Reg Anesth Pain Med 2002 27 : 332 333.
    • (2002) Reg Anesth Pain Med , vol.27 , pp. 332-333
    • Moon, J.K.1
  • 20
    • 85066061941 scopus 로고    scopus 로고
    • Fascicular anatomy, nervi nervorum, and paresthesia
    • Carrero G. Fascicular anatomy, nervi nervorum, and paresthesia. Reg Anesth Pain Med 2003 28 : 72 3.
    • (2003) Reg Anesth Pain Med , vol.28 , pp. 72-3
    • Carrero, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.