메뉴 건너뛰기




Volumn 33, Issue 3, 2010, Pages 565-575

Impact of stent design on in-stent stenosis in a rabbit iliac artery model

Author keywords

Crown; In stent stenosis; Injury; Stent design; Strut thickness; Wave

Indexed keywords

ANGIOSCOPY; ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTERY DIAMETER; ARTICLE; BLOOD VESSEL INJURY; COMPARATIVE STUDY; CONTROLLED STUDY; EQUIPMENT DESIGN; EXPERIMENTAL MODEL; FOLLOW UP; ILIAC ARTERY; IMPLANTATION; IN-STENT RESTENOSIS; INTIMA; MALE; NONHUMAN; PRIORITY JOURNAL; RABBIT; STENT; VASCULITIS;

EID: 77953135411     PISSN: 01741551     EISSN: 1432086X     Source Type: Journal    
DOI: 10.1007/s00270-009-9757-6     Document Type: Article
Times cited : (8)

References (42)
  • 1
    • 0027934377 scopus 로고
    • A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent restenosis study investigators
    • Fischman DL, Leon MB, Baim DS et al (1994) A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. N Engl J Med 331(8):496-501
    • (1994) N. Engl. J. Med. , vol.331 , Issue.8 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 2
    • 33847167065 scopus 로고    scopus 로고
    • Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxeleluting stents in routine clinical practice: Data from a large twoinstitutional cohort study
    • Daemen J, Wenaweser P, Tsuchida K et al (2007) Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxeleluting stents in routine clinical practice: data from a large twoinstitutional cohort study. Lancet 369(9562):667-678
    • (2007) Lancet , vol.369 , Issue.9562 , pp. 667-678
    • Daemen, J.1    Wenaweser, P.2    Tsuchida, K.3
  • 3
    • 0031689616 scopus 로고    scopus 로고
    • Gamma versus beta radiation for the treatment of restenosis
    • Teirstein PS (1998) Gamma versus beta radiation for the treatment of restenosis. Herz 23(6):335-336
    • (1998) Herz , vol.23 , Issue.6 , pp. 335-336
    • Teirstein, P.S.1
  • 4
    • 33644909898 scopus 로고    scopus 로고
    • 64-slice multidetector coronary CT angiography: In vitro evaluation of 68 different stents
    • Maintz D, Seifarth H, Raupach R et al (2006) 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol 16(4):818-826
    • (2006) Eur. Radiol. , vol.16 , Issue.4 , pp. 818-826
    • Maintz, D.1    Seifarth, H.2    Raupach, R.3
  • 6
    • 24944472978 scopus 로고    scopus 로고
    • Carotid artery stenting: Which stent for which lesion?
    • Bosiers M, Deloose K, Verbist J, Peeters P (2005) Carotid artery stenting: Which stent for which lesion? Vascular 13(4):205-210
    • (2005) Vascular , vol.13 , Issue.4 , pp. 205-210
    • Bosiers, M.1    Deloose, K.2    Verbist, J.3    Peeters, P.4
  • 7
    • 0034058034 scopus 로고    scopus 로고
    • Stent longitudinal flexibility: A comparison of 13 stent designs before and after balloon expansion
    • Ormiston JA, Dixon SR, Webster MW et al (2000) Stent longitudinal flexibility: a comparison of 13 stent designs before and after balloon expansion. Catheter Cardiovasc Interv 50(1):120-124
    • (2000) Catheter Cardiovasc. Interv. , vol.50 , Issue.1 , pp. 120-124
    • Ormiston, J.A.1    Dixon, S.R.2    Webster, M.W.3
  • 8
    • 0035849543 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO) trial
    • Kastrati A, Mehilli J, Dirschinger J et al (2001) Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 103(23):2816-2821
    • (2001) Circulation , vol.103 , Issue.23 , pp. 2816-2821
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 9
    • 25144508347 scopus 로고    scopus 로고
    • Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: A prospective, randomized trial
    • Pache J, Dibra A, Mehilli J et al (2005) Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: a prospective, randomized trial. Eur Heart J 26(13):1262-1268
    • (2005) Eur. Heart J. , vol.26 , Issue.13 , pp. 1262-1268
    • Pache, J.1    Dibra, A.2    Mehilli, J.3
  • 10
    • 0037392914 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial
    • Pache J, Kastrati A, Mehilli J et al (2003) Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. J Am Coll Cardiol 41(8):1283-1288
    • (2003) J. Am. Coll. Cardiol. , vol.41 , Issue.8 , pp. 1283-1288
    • Pache, J.1    Kastrati, A.2    Mehilli, J.3
  • 11
    • 1242338056 scopus 로고    scopus 로고
    • Impact of strut thickness on late luminal loss after coronary artery stent placement
    • Rittersma SZ, de Winter RJ, Koch KT et al (2004) Impact of strut thickness on late luminal loss after coronary artery stent placement. Am J Cardiol 93(4):477-480
    • (2004) Am. J. Cardiol. , vol.93 , Issue.4 , pp. 477-480
    • Rittersma, S.Z.1    De Winter, R.J.2    Koch, K.T.3
  • 12
    • 0036760047 scopus 로고    scopus 로고
    • Comparison of the morphological changes of restenosis after the implantation of various types of stents in a swine model
    • Yorozuya M, Suzuki H, Iso Y et al (2002) Comparison of the morphological changes of restenosis after the implantation of various types of stents in a swine model. Coron Artery Dis 13(6):305-312
    • (2002) Coron Artery Dis. , vol.13 , Issue.6 , pp. 305-312
    • Yorozuya, M.1    Suzuki, H.2    Iso, Y.3
  • 13
    • 34147129251 scopus 로고    scopus 로고
    • The efficacy of nanoscale poly[bis (trifluoroethoxy) phosphazene] (PTFEP) coatings in reducing thrombogenicity and late in-stent stenosis in a porcine coronary artery model
    • Satzl S, Henn C, Christoph P, Kurz P et al (2007) The efficacy of nanoscale poly[bis (trifluoroethoxy) phosphazene] (PTFEP) coatings in reducing thrombogenicity and late in-stent stenosis in a porcine coronary artery model. Invest Radiol 42(5):303-311
    • (2007) Invest. Radiol. , vol.42 , Issue.5 , pp. 303-311
    • Satzl, S.1    Henn, C.2    Christoph, P.3    Kurz, P.4
  • 14
    • 6444221460 scopus 로고    scopus 로고
    • Preclinical evaluation of drug-eluting stents for peripheral applications: Recommendations from an expert consensus group
    • Schwartz RS, Edelman ER, Carter A et al (2004) Preclinical evaluation of drug-eluting stents for peripheral applications: recommendations from an expert consensus group. Circulation 110(16):2498-2505
    • (2004) Circulation , vol.110 , Issue.16 , pp. 2498-2505
    • Schwartz, R.S.1    Edelman, E.R.2    Carter, A.3
  • 15
    • 0036789493 scopus 로고    scopus 로고
    • Drug-eluting stents in preclinical studies: Recommended evaluation from a consensus group
    • Schwartz RS, Edelman ER, Carter A et al (2002) Drug-eluting stents in preclinical studies: recommended evaluation from a consensus group. Circulation 106(14):1867-1873
    • (2002) Circulation , vol.106 , Issue.14 , pp. 1867-1873
    • Schwartz, R.S.1    Edelman, E.R.2    Carter, A.3
  • 16
    • 0031885670 scopus 로고    scopus 로고
    • In-stent restenosis: Contributions of inflammatory responses and arterial injury to neointimal hyperplasia
    • Kornowski R, Hong MK, Tio FO et al (1998) In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia. J Am Coll Cardiol 31(1):224-230
    • (1998) J. Am. Coll. Cardiol. , vol.31 , Issue.1 , pp. 224-230
    • Kornowski, R.1    Hong, M.K.2    Tio, F.O.3
  • 17
    • 58849100491 scopus 로고    scopus 로고
    • Does carotid stent design influence outcomes?
    • Bersin RM (2008) Does carotid stent design influence outcomes? Catheter Cardiovasc Interv 72(6):863-866
    • (2008) Catheter Cardiovasc. Interv. , vol.72 , Issue.6 , pp. 863-866
    • Bersin, R.M.1
  • 18
    • 0031831503 scopus 로고    scopus 로고
    • Evaluation of the compressive mechanical properties of endoluminal metal stents
    • Schrader SC, Beyar R (1998) Evaluation of the compressive mechanical properties of endoluminal metal stents. Cathet Cardiovasc Diagn 44(2):179-187
    • (1998) Cathet Cardiovasc. Diagn. , vol.44 , Issue.2 , pp. 179-187
    • Schrader, S.C.1    Beyar, R.2
  • 19
    • 0029004856 scopus 로고
    • Endovascular stent design dictates experimental restenosis and thrombosis
    • Rogers C, Edelman ER (1995) Endovascular stent design dictates experimental restenosis and thrombosis. Circulation 91(12):2995-3001
    • (1995) Circulation , vol.91 , Issue.12 , pp. 2995-3001
    • Rogers, C.1    Edelman, E.R.2
  • 20
    • 61349173117 scopus 로고    scopus 로고
    • Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting
    • Pierce DS, Rosero EB, Modrall JG et al (2009) Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting. J Vasc Surg 49(3):602-606;
    • (2009) J. Vasc. Surg. , vol.49 , Issue.3 , pp. 602-606
    • Pierce, D.S.1    Rosero, E.B.2    Modrall, J.G.3
  • 21
    • 77953129135 scopus 로고    scopus 로고
    • discussion
    • discussion 606
  • 22
    • 27744458817 scopus 로고    scopus 로고
    • Axial stent strut angle influences wall shear stress after stent implantation: Analysis using 3D computational fluid dynamics models of stent foreshortening
    • La Disa JF Jr, Olson LE, Hettrick DA et al (2005) Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening. Biomed Eng Online 4:59
    • (2005) Biomed. Eng. Online , vol.4 , pp. 59
    • La Disa Jr., J.F.1    Olson, L.E.2    Hettrick, D.A.3
  • 23
    • 0037302902 scopus 로고    scopus 로고
    • Resistance to hoop stress in balloon expandable stents: Evaluation in an ex vivo model
    • Grenacher L, Deutsch J, Lubienski A, Richter GM (2003) Resistance to hoop stress in balloon expandable stents: evaluation in an ex vivo model. Invest Radiol 38(2):65-72
    • (2003) Invest. Radiol. , vol.38 , Issue.2 , pp. 65-72
    • Grenacher, L.1    Deutsch, J.2    Lubienski, A.3    Richter, G.M.4
  • 24
    • 2642596064 scopus 로고    scopus 로고
    • Restenosis of peripheral stents and stent grafts as revealed by intravascular sonography: In vivo comparison with angiography
    • Schwarzenberg H, Muller-Hulsbeck S, Gluer CC et al (1998) Restenosis of peripheral stents and stent grafts as revealed by intravascular sonography: in vivo comparison with angiography. AJR Am J Roentgenol 170(5):1181-1185
    • (1998) AJR Am. J. Roentgenol. , vol.170 , Issue.5 , pp. 1181-1185
    • Schwarzenberg, H.1    Muller-Hulsbeck, S.2    Gluer, C.C.3
  • 25
    • 0032996076 scopus 로고    scopus 로고
    • Effect of stent design on reduction of elastic recoil: A comparison via quantitative intravascular ultrasound
    • Yamamoto Y, Brown DL, Ischinger TA et al (1999) Effect of stent design on reduction of elastic recoil: a comparison via quantitative intravascular ultrasound. Catheter Cardiovasc Interv 47(2):251-257
    • (1999) Catheter Cardiovasc. Interv. , vol.47 , Issue.2 , pp. 251-257
    • Yamamoto, Y.1    Brown, D.L.2    Ischinger, T.A.3
  • 26
    • 0036847067 scopus 로고    scopus 로고
    • Influence of stent design and material composition on procedure outcome
    • Palmaz JC, Bailey S, Marton D, Sprague E (2002) Influence of stent design and material composition on procedure outcome. J Vasc Surg 36(5):1031-1039
    • (2002) J. Vasc. Surg. , vol.36 , Issue.5 , pp. 1031-1039
    • Palmaz, J.C.1    Bailey, S.2    Marton, D.3    Sprague, E.4
  • 27
    • 23644444112 scopus 로고    scopus 로고
    • Blood flow in stented arteries: A parametric comparison of strut design patterns in three dimensions
    • He Y, Duraiswamy N, Frank AO, Moore JE Jr (2005) Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng 127(4):637-647
    • (2005) J. Biomech. Eng. , vol.127 , Issue.4 , pp. 637-647
    • He, Y.1    Duraiswamy, N.2    Frank, A.O.3    Moore Jr., J.E.4
  • 28
    • 0032948182 scopus 로고    scopus 로고
    • Influence of surface topography on endothelialization of intravascular metallic material
    • Palmaz JC, Benson A, Sprague EA (1999) Influence of surface topography on endothelialization of intravascular metallic material. J Vasc Interv Radiol 10(4):439-444
    • (1999) J. Vasc. Interv. Radiol. , vol.10 , Issue.4 , pp. 439-444
    • Palmaz, J.C.1    Benson, A.2    Sprague, E.A.3
  • 29
    • 3042567527 scopus 로고    scopus 로고
    • Stent design properties and deployment ratio influence indexes of wall shear stress: A three-dimensional computational fluid dynamics investigation within a normal artery
    • La Disa JF Jr, Olson LE, Guler I et al (2004) Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery. J Appl Physiol 97(1):424-430;
    • (2004) J. Appl. Physiol. , vol.97 , Issue.1 , pp. 424-430
    • La Disa Jr., J.F.1    Olson, L.E.2    Guler, I.3
  • 30
    • 77953137049 scopus 로고    scopus 로고
    • discussion
    • discussion 416
  • 31
    • 0037036821 scopus 로고    scopus 로고
    • In-stent restenosis in small coronary arteries: Impact of strut thickness
    • Briguori C, Sarais C, Pagnotta P et al (2002) In-stent restenosis in small coronary arteries: impact of strut thickness. J Am Coll Cardiol 40(3):403-409
    • (2002) J. Am. Coll. Cardiol. , vol.40 , Issue.3 , pp. 403-409
    • Briguori, C.1    Sarais, C.2    Pagnotta, P.3
  • 32
    • 0024571386 scopus 로고
    • A view of vascular stents
    • Schatz RA (1989) A view of vascular stents. Circulation 79(2):445-457
    • (1989) Circulation , vol.79 , Issue.2 , pp. 445-457
    • Schatz, R.A.1
  • 33
    • 0031760678 scopus 로고    scopus 로고
    • The stent decade: 1987 to 1997. Stanford stent summit faculty
    • Oesterle SN, Whitbourn R, Fitzgerald PJ, et al. (1998) The stent decade: 1987 to 1997. Stanford Stent Summit faculty. Am Heart J 136 (4; Pt 1):578-599
    • (1998) Am. Heart J. , vol.136 , Issue.1-4 PT. , pp. 578-599
    • Oesterle, S.N.1    Whitbourn, R.2    Fitzgerald, P.J.3
  • 34
    • 0032421595 scopus 로고    scopus 로고
    • Artery size, neointima, and remodeling: Time for some standards
    • Schwartz RS, Topol EJ, Serruys PW et al (1998) Artery size, neointima, and remodeling: time for some standards. J Am Coll Cardiol 32(7):2087-2094
    • (1998) J. Am. Coll. Cardiol. , vol.32 , Issue.7 , pp. 2087-2094
    • Schwartz, R.S.1    Topol, E.J.2    Serruys, P.W.3
  • 35
    • 0029817977 scopus 로고    scopus 로고
    • Hoop dreams. Stents without restenosis
    • Edelman ER, Rogers C (1996) Hoop dreams. Stents without restenosis. Circulation 94(6):1199-1202
    • (1996) Circulation , vol.94 , Issue.6 , pp. 1199-1202
    • Edelman, E.R.1    Rogers, C.2
  • 36
    • 0036298338 scopus 로고    scopus 로고
    • Open-cell design stents in congenital heart disease: A comparison of intra stent vs. palmaz stents
    • Kreutzer J, Rome JJ (2002) Open-cell design stents in congenital heart disease: a comparison of Intra Stent vs. Palmaz stents. Catheter Cardiovasc Interv 56(3):400-409
    • (2002) Catheter Cardiovasc. Interv. , vol.56 , Issue.3 , pp. 400-409
    • Kreutzer, J.1    Rome, J.J.2
  • 37
    • 0034080259 scopus 로고    scopus 로고
    • Influence of topography on endothelialization of stents: Clues for new designs
    • Simon C, Palmaz JC, Sprague EA (2000) Influence of topography on endothelialization of stents: clues for new designs. J Long Term Eff Med Implants 10(1-2):143-151
    • (2000) J. Long Term Eff. Med. Implants , vol.10 , Issue.1-2 , pp. 143-151
    • Simon, C.1    Palmaz, J.C.2    Sprague, E.A.3
  • 38
    • 0030186375 scopus 로고    scopus 로고
    • Arterial remodeling after coronary angioplasty: A serial intravascular ultrasound study
    • Mintz GS, Popma JJ, Pichard AD et al (1996) Arterial remodeling after coronary angioplasty: a serial intravascular ultrasound study. Circulation 94(1):35-43
    • (1996) Circulation , vol.94 , Issue.1 , pp. 35-43
    • Mintz, G.S.1    Popma, J.J.2    Pichard, A.D.3
  • 39
    • 0032421595 scopus 로고    scopus 로고
    • Artery size, neointima, and remodeling: Time for some standards
    • Schwartz RS, Topol EJ, Serruys PW et al (1998) Artery size, neointima, and remodeling: time for some standards. J Am Coll Cardiol 32(7):2087-2094
    • (1998) J. Am. Coll. Cardiol. , vol.32 , Issue.7 , pp. 2087-2094
    • Schwartz, R.S.1    Topol, E.J.2    Serruys, P.W.3
  • 40
    • 0029837889 scopus 로고    scopus 로고
    • Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study
    • Hoffmann R, Mintz GS, Dussaillant GR et al (1996) Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. Circulation 94(6):1247-1254
    • (1996) Circulation , vol.94 , Issue.6 , pp. 1247-1254
    • Hoffmann, R.1    Mintz, G.S.2    Dussaillant, G.R.3
  • 41
    • 0033231166 scopus 로고    scopus 로고
    • Propensity and mechanisms of restenosis in different coronary stent designs: Complementary value of the analysis of the luminal gain-loss relationship
    • Escaned J, Goicolea J, Alfonso F et al (1999) Propensity and mechanisms of restenosis in different coronary stent designs: complementary value of the analysis of the luminal gain-loss relationship. J Am Coll Cardiol 34(5):1490-1497
    • (1999) J. Am. Coll. Cardiol. , vol.34 , Issue.5 , pp. 1490-1497
    • Escaned, J.1    Goicolea, J.2    Alfonso, F.3
  • 42
    • 0028358762 scopus 로고
    • The relative importance of arterial remodeling compared with intimal hyperplasia in lumen renarrowing after balloon angioplasty. A study in the normal rabbit and the hypercholesterolemic Yucatan micropig
    • Post MJ, Borst C, Kuntz RE (1994) The relative importance of arterial remodeling compared with intimal hyperplasia in lumen renarrowing after balloon angioplasty. A study in the normal rabbit and the hypercholesterolemic Yucatan micropig. Circulation 89(6):2816-2821
    • (1994) Circulation , vol.89 , Issue.6 , pp. 2816-2821
    • Post, M.J.1    Borst, C.2    Kuntz, R.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.