메뉴 건너뛰기




Volumn 93, Issue 4, 2004, Pages 477-480

Impact of strut thickness on late luminal loss after coronary artery stent placement

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; TICLOPIDINE;

EID: 1242338056     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2003.10.049     Document Type: Article
Times cited : (87)

References (11)
  • 1
    • 0029004856 scopus 로고
    • Endovascular stent design dictates experimental restenosis and thrombosis
    • Rogers C., Edelman E.R. Endovascular stent design dictates experimental restenosis and thrombosis. Circulation. 91:1995;2995-3001.
    • (1995) Circulation , vol.91 , pp. 2995-3001
    • Rogers, C.1    Edelman, E.R.2
  • 3
    • 0037097491 scopus 로고    scopus 로고
    • Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound
    • Hoffmann R., Mintz G.S., Haager P.K., Bozoglu T., Grube E., Gross M., Beythien C., Mudra H., vom Dahl J., Hanrath P. Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound. Am J Cardiol. 89:2002;1360-1364.
    • (2002) Am J Cardiol , vol.89 , pp. 1360-1364
    • Hoffmann, R.1    Mintz, G.S.2    Haager, P.K.3    Bozoglu, T.4    Grube, E.5    Gross, M.6    Beythien, C.7    Mudra, H.8    Vom Dahl, J.9    Hanrath, P.10
  • 8
    • 0037044449 scopus 로고    scopus 로고
    • Angiographic findings of the multicenter Randomized Study with the sirolimus-eluting Bx Velocity balloon-Expandable stent (RAVEL): Sirolimus-eluting stents inhibit restenosis irrespective of the vessel size
    • Regar E., Serruys P.W., Bode C., Holubarsch C., Guermonprez J.L., Wijns W., Bartorelli A., Constantini C., Degertekin M., Tanabe K., et al. Angiographic findings of the multicenter Randomized Study with the sirolimus-eluting Bx Velocity balloon-Expandable stent (RAVEL) sirolimus-eluting stents inhibit restenosis irrespective of the vessel size . Circulation. 106:2002;1949-1956.
    • (2002) Circulation , vol.106 , pp. 1949-1956
    • Regar, E.1    Serruys, P.W.2    Bode, C.3    Holubarsch, C.4    Guermonprez, J.L.5    Wijns, W.6    Bartorelli, A.7    Constantini, C.8    Degertekin, M.9    Tanabe, K.10
  • 10
    • 0028182835 scopus 로고
    • A new approach for the quantification of complex lesion morphology: The gradient field transform; Basic principles and validation results
    • van der Zwet P.M., Reiber J.H. A new approach for the quantification of complex lesion morphology the gradient field transform; basic principles and validation results . J Am Coll Cardiol. 24:1994;216-224.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 216-224
    • Van Der Zwet, P.M.1    Reiber, J.H.2
  • 11
    • 0035818614 scopus 로고    scopus 로고
    • Clinical and angiographic factors associated with asymptomatic restenosis after percutaneous coronary intervention
    • Ruygrok P.N., Webster M.W., de Valk V., van Es G.A., Ormiston J.A., Morel M.A., Serruys P.W. Clinical and angiographic factors associated with asymptomatic restenosis after percutaneous coronary intervention. Circulation. 104:2001;2289-2294.
    • (2001) Circulation , vol.104 , pp. 2289-2294
    • Ruygrok, P.N.1    Webster, M.W.2    De Valk, V.3    Van Es, G.A.4    Ormiston, J.A.5    Morel, M.A.6    Serruys, P.W.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.