Volumn 27, Issue 3, 2010, Pages 129-141

The platinum chromium element stent platform: From alloy, to design, to clinical practice

Author keywords

Cobalt chromium stent; Coronary stent; Platinum chromium stent; Radial strength; Radiopacity; Stainless steel stent; Strut thickness

Indexed keywords

ALLOY; CHROMIUM; COBALT; EVEROLIMUS; GOLD; IRON; MANGANESE; MOLYBDENUM; NICKEL; PACLITAXEL; PLATINUM; POLYMETHACRYLIC ACID DERIVATIVE; POLYSTYRENE DERIVATIVE; POLYVINYLIDENE FLUORIDE; PROPYLENE; STAINLESS STEEL; TANTALUM; TITANIUM; TUNGSTEN;

EID: 77953021036     PISSN: 0741238X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12325-010-0022-9     Document Type: Review
Times cited : (106)

References (23)
  • 1
    • 0035849543 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results: Strut thickness effect on REstenosis outcome (ISAR-STEREO) trial
    • Kastrati A, Mehilli J, Dirschinger J, et al. Intracoronary Stenting and Angiographic Results: Strut Thickness Effect on REstenosis Outcome (ISAR-STEREO) trial. Circulation. 2001;103:2816- 2821.
    • (2001) Circulation , vol.103 , pp. 2816-2821
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 2
    • 0037036821 scopus 로고    scopus 로고
    • In-stent restenosis in small coronary arteries: Impact of strut thickness
    • Briguori C, Sarais C, Pagnotta P, et al. In-stent restenosis in small coronary arteries: impact of strut thickness. J Am Coll Cardiol. 2002;40:403-409.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 403-409
    • Briguori, C.1    Sarais, C.2    Pagnotta, P.3
  • 3
    • 0242720673 scopus 로고    scopus 로고
    • Impact of lesion complexity on the capacity of a trial to detect differences in stent performance: Results from the ISAR-STEREO trial
    • Hausleiter J, Kastrati A, Mehilli J, et al. Impact of lesion complexity on the capacity of a trial to detect differences in stent performance: results from the ISAR-STEREO trial. Am Heart J. 2003;146:882-886.
    • (2003) Am Heart J , vol.146 , pp. 882-886
    • Hausleiter, J.1    Kastrati, A.2    Mehilli, J.3
  • 4
    • 1242338056 scopus 로고    scopus 로고
    • Impact of strut thickness on late luminal loss after coronary artery stent placement
    • Rittersma SZ, de Winter RJ, Koch KT, et al. Impact of strut thickness on late luminal loss after coronary artery stent placement. Am J Cardiol. 2004;93:477-480.
    • (2004) Am J Cardiol , vol.93 , pp. 477-480
    • Rittersma, S.Z.1    De Winter, R.J.2    Koch, K.T.3
  • 5
    • 0037392914 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial
    • Pache J, Kastrati A, Mehilli J, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. J Am Coll Cardiol. 2003;41:1283-1288.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 1283-1288
    • Pache, J.1    Kastrati, A.2    Mehilli, J.3
  • 6
    • 57549094617 scopus 로고    scopus 로고
    • Reduced risk of restenosis in small vessels and reduced risk of myocardial infarction in long lesions with the new thin-strut Taxus Liberté stent: One-year results from the Taxus ATLAS program
    • Turco M, Ormiston JA, Popma JJ, et al. Reduced risk of restenosis in small vessels and reduced risk of myocardial infarction in long lesions with the new thin-strut Taxus Liberté stent: one-year results from the Taxus ATLAS program. JACC Cardiovasc Interv. 2008;1:699-709.
    • (2008) JACC Cardiovasc Interv , vol.1 , pp. 699-709
    • Turco, M.1    Ormiston, J.A.2    Popma, J.J.3
  • 7
    • 0342858846 scopus 로고    scopus 로고
    • Increased risk of restensosis after placement of gold-coated stents
    • Kastrati A, Schomig A, Dirschinger J, et al. Increased risk of restensosis after placement of gold-coated stents. Circulation. 2000;101:2478-2483.
    • (2000) Circulation , vol.101 , pp. 2478-2483
    • Kastrati, A.1    Schomig, A.2    Dirschinger, J.3
  • 8
    • 2342518238 scopus 로고    scopus 로고
    • The NUGGET study: NIR ultra gold-gilded equivalency trial
    • Reifart N, Morice MC, Silber S, et al. The NUGGET study: NIR ultra gold-gilded equivalency trial. Catheter Cardiovasc Interv. 2004;62:18-25.
    • (2004) Catheter Cardiovasc Interv , vol.62 , pp. 18-25
    • Reifart, N.1    Morice, M.C.2    Silber, S.3
  • 9
    • 0041562602 scopus 로고    scopus 로고
    • Usefulness of a cobalt chromium coronary stent alloy
    • Kereiakes DJ, Cox DA, Hermiller JB, et al. Usefulness of a cobalt chromium coronary stent alloy. Am J Cardiol. 2003;92:463-466.
    • (2003) Am J Cardiol , vol.92 , pp. 463-466
    • Kereiakes, D.J.1    Cox, D.A.2    Hermiller, J.B.3
  • 10
    • 0038513583 scopus 로고    scopus 로고
    • Development of a platinum-enhanced radiopaque stainless steel (PERSS)
    • Winters GL, Nutt MJ, eds., Conshohocken, PA: ASTM International
    • Craig CH, Radisch HR, Trozera TA, et al. Development of a platinum-enhanced radiopaque stainless steel (PERSS). In: Winters GL, Nutt MJ, eds. Stainless Steels for Medical and Surgical Applications, ASTM STP 1438. Conshohocken, PA: ASTM International; 2003;28-38.
    • (2003) Stainless Steels for Medical and Surgical Applications, ASTM STP 1438 , pp. 28-38
    • Craig, C.H.1    Radisch, H.R.2    Trozera, T.A.3
  • 11
    • 0141989974 scopus 로고    scopus 로고
    • Mechanical properties and microstructure of platinum enhanced radiopaque stainless steel (PERSS) alloys
    • Craig CH, Friend CM, Edwards MR, Cornish LA, Goken NA. Mechanical properties and microstructure of platinum enhanced radiopaque stainless steel (PERSS) alloys. J Alloys Comp. 2003;361:187-199.
    • (2003) J Alloys Comp , vol.361 , pp. 187-199
    • Craig, C.H.1    Friend, C.M.2    Edwards, M.R.3    Cornish, L.A.4    Goken, N.A.5
  • 12
    • 77649273239 scopus 로고    scopus 로고
    • A platinumchromium steel for cardiovascular stents
    • O'Brien BJ, Stinson JS, Larsen SR, et al. A platinumchromium steel for cardiovascular stents. Biomaterials. 2010;31:3755-3761.
    • (2010) Biomaterials , vol.31 , pp. 3755-3761
    • O'Brien, B.J.1    Stinson, J.S.2    Larsen, S.R.3
  • 13
    • 0036855451 scopus 로고    scopus 로고
    • Immediate and long-term results of implantation of the new platinum coronary stent (Atlas stent) in patients with coronary artery disease
    • Article in Spanish
    • Abundes A, Rivera J de J, Arizmendi E, et al. [Immediate and long-term results of implantation of the new platinum coronary stent (Atlas stent) in patients with coronary artery disease]. Rev Esp Cardiol. 2002;55:1205-1208. Article in Spanish.
    • (2002) Rev Esp Cardiol , vol.55 , pp. 1205-1208
    • Abundes, A.1    Rivera, J.D.J.2    Arizmendi, E.3
  • 14
    • 33645414550 scopus 로고    scopus 로고
    • Covered Cheatham-platinum stents for aortic coarctation: Early and intermediate-term results
    • Tzifa A, Ewert P, Brzezinska-Rajszys G, et al. Covered Cheatham-platinum stents for aortic coarctation: early and intermediate-term results. J Am Coll Cardiol. 2006;47:1457-1463.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1457-1463
    • Tzifa, A.1    Ewert, P.2    Brzezinska-Rajszys, G.3
  • 15
    • 33846363236 scopus 로고    scopus 로고
    • Is stent placement effective for palliation of right ventricle to pulmonary artery conduit stenosis?
    • Aggarwal S, Garekar S, Forbes TJ, Turner DR. Is stent placement effective for palliation of right ventricle to pulmonary artery conduit stenosis? J Am Coll Cardiol. 2007;49:480-484.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 480-484
    • Aggarwal, S.1    Garekar, S.2    Forbes, T.J.3    Turner, D.R.4
  • 16
    • 64249168271 scopus 로고    scopus 로고
    • The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: A review
    • O'Brien B, Carroll W. The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: a review. Acta Materialia. 2009;5:945-958.
    • (2009) Acta Materialia , vol.5 , pp. 945-958
    • O'Brien, B.1    Carroll, W.2
  • 17
    • 33745120500 scopus 로고    scopus 로고
    • Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications
    • Haidopoulos M, Turgeon S, Sarra-Bournet C, Laroche G, Mantovani D. Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications. J Mater Sci Mater Med. 2006;17:647-657.
    • (2006) J Mater Sci Mater Med , vol.17 , pp. 647-657
    • Haidopoulos, M.1    Turgeon, S.2    Sarra-Bournet, C.3    Laroche, G.4    Mantovani, D.5
  • 19
    • 77953028843 scopus 로고    scopus 로고
    • TAXUS PERSEUS: A novel platinum chromium, thin-strut TAXUS Element stent for the treatment of de novo coronary stenoses
    • Presented at:, March 15, Atlanta, GA
    • Kereiakes D, et al. TAXUS PERSEUS: a novel platinum chromium, thin-strut TAXUS Element stent for the treatment of de novo coronary stenoses. Presented at: ACC/i2Late Breaking Trials. American College of Cardiology annual meeting; March 15, 2010; Atlanta, GA.
    • (2010) ACC/i2Late Breaking Trials. American College of Cardiology Annual Meeting
    • Kereiakes, D.1
  • 22
    • 34247151092 scopus 로고    scopus 로고
    • Polymerbased, paclitaxel-eluting Taxus Liberté stent in de novo lesions: The pivotal Taxus ATLAS trial
    • Turco MA, Ormiston JA, Popma JJ, et al. Polymerbased, paclitaxel-eluting Taxus Liberté stent in de novo lesions: the pivotal Taxus ATLAS trial. J Am Coll Cardiol. 2007;49:1676-1683.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 1676-1683
    • Turco, M.A.1    Ormiston, J.A.2    Popma, J.J.3
  • 23
    • 77953027571 scopus 로고    scopus 로고
    • Data on file. Testing conducted at Boston Scientific; 2008
    • Data on file. Testing conducted at Boston Scientific; 2008.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.