메뉴 건너뛰기




Volumn 14, Issue 3, 2010, Pages 300-309

Comparison of active cooling devices with passive cooling for rehabilitation of firefighters performing exercise in thermal protective clothing: A report from the fireground rehab evaluation (FIRE) trial

Author keywords

Cardiovascular strain; Cooling; Firefighter; Heat strain; Performance; Thermal stress

Indexed keywords

ADULT; ARTICLE; BODY TEMPERATURE; COMPARATIVE STUDY; CRYOTHERAPY; EMPLOYMENT; EXERCISE; FEMALE; FIRE; HEAT EXHAUSTION; HUMAN; INSTRUMENTATION; MALE; PATHOPHYSIOLOGY; PHYSIOLOGY; PROTECTIVE CLOTHING; TASK PERFORMANCE;

EID: 77952986405     PISSN: 10903127     EISSN: 15450066     Source Type: Journal    
DOI: 10.3109/10903121003770654     Document Type: Article
Times cited : (80)

References (24)
  • 1
    • 4444268754 scopus 로고    scopus 로고
    • Cardiovascular and thermal consequences of protective clothing: A comparison of clothed and unclothed states
    • Fogarty A, Armstrong K, Gordon C, et al. Cardiovascular and thermal consequences of protective clothing: a comparison of clothed and unclothed states. Ergonomics. 2004;47:1073-1086
    • (2004) Ergonomics , vol.47 , pp. 1073-1086
    • Fogarty, A.1    Armstrong, K.2    Gordon, C.3
  • 2
    • 0032763185 scopus 로고    scopus 로고
    • Effects of fire fighting uniform (modern, modified modern, and traditional) design changes on exercise duration in New York City firefighters
    • Malley KS, Goldstein AM, Aldrich TK, et al. Effects of fire fighting uniform (modern, modified modern, and traditional) design changes on exercise duration inNew York City firefighters. J Occup Environ Med. 1999;41:1104-1115
    • (1999) J Occup Environ Med , vol.41 , pp. 1104-1115
    • Malley, K.S.1    Goldstein, A.M.2    Aldrich, T.K.3
  • 3
    • 0032784974 scopus 로고    scopus 로고
    • Heat balance when wearing protective clothing
    • Havenith G. Heat balance when wearing protective clothing. Ann Occup Hyg. 1999;43:289-296
    • (1999) Ann Occup Hyg , vol.43 , pp. 289-296
    • Havenith, G.1
  • 5
    • 0032901974 scopus 로고    scopus 로고
    • Effectiveness of rest pauses and cooling in alleviation of heat stress during simulated fire-fighting activity
    • Carter JB, Banister EW, Morrison JB. Effectiveness of rest pauses and cooling in alleviation of heat stress during simulated fire-fighting activity. Ergonomics. 1999;42: 299-313
    • (1999) Ergonomics , vol.42 , pp. 299-313
    • Carter, J.B.1    Banister, E.W.2    Morrison, J.B.3
  • 7
    • 34249904699 scopus 로고    scopus 로고
    • Cooling hyperthermic firefighters by immersing forearms and hands in 10 degrees C and 20 degrees C water
    • Giesbrecht GG, Jamieson C, Cahill F. Cooling hyperthermic firefighters by immersing forearms and hands in 10 degrees C and 20 degrees C water. Aviat Space Environ Med. 2007;78:561-567
    • (2007) Aviat Space Environ Med , vol.78 , pp. 561-567
    • Giesbrecht, G.G.1    Jamieson, C.2    Cahill, F.3
  • 9
    • 64049113049 scopus 로고    scopus 로고
    • A new hand-cooling device to enhance firefighter heat strain recovery
    • Zhang Y, Bishop P, Casaru C, Davis J. A new hand-cooling device to enhance firefighter heat strain recovery. J Occup Environ Hyg. 2009;6:283-288
    • (2009) J Occup Environ Hyg , vol.6 , pp. 283-288
    • Zhang, Y.1    Bishop, P.2    Casaru, C.3    Davis, J.4
  • 10
    • 3242657128 scopus 로고    scopus 로고
    • Active versus passive cooling during work in warm environments while wearing firefighting protective clothing
    • Selkirk GA, McLellan TM, Wong J. Active versus passive cooling during work in warm environments while wearing firefighting protective clothing. J Occup Environ Hyg. 2004;1:521-531
    • (2004) J Occup Environ Hyg , vol.1 , pp. 521-531
    • Selkirk, G.A.1    McLellan, T.M.2    Wong, J.3
  • 11
    • 0018126462 scopus 로고
    • Generalized equations for predicting body density of men
    • Jackson AS, Pollock ML. Generalized equations for predicting body density of men. Br J Nutr. 1978;40:497-504
    • (1978) Br J Nutr , vol.40 , pp. 497-504
    • Jackson, A.S.1    Pollock, M.L.2
  • 14
    • 0031885338 scopus 로고    scopus 로고
    • Telemetry pill measurement of core temperature in humans during active heating and cooling
    • O'Brien C, Hoyt RW, Buller MJ, Castellani JW, Young AJ. Telemetry pill measurement of core temperature in humans during active heating and cooling. Med Sci Sports Exerc. 1998;30:468-472
    • (1998) Med Sci Sports Exerc , vol.30 , pp. 468-472
    • O'Brien, C.1    Hoyt, R.W.2    Buller, M.J.3    Castellani, J.W.4    Young, A.J.5
  • 15
    • 1842558606 scopus 로고    scopus 로고
    • Physical work limits for Toronto firefighters in warm environments
    • Selkirk GA, McLellan TM. Physical work limits for Toronto firefighters in warm environments. J Occup Environ Hyg. 2004;1:199-212
    • (2004) J Occup Environ Hyg , vol.1 , pp. 199-212
    • Selkirk, G.A.1    McLellan, T.M.2
  • 16
    • 0033174186 scopus 로고    scopus 로고
    • Effects of dehydration, hypohydration, and hyperhydration on tolerance during uncompensable heat stress
    • McLellan TM, Cheung SS, Latzka WA, et al. Effects of dehydration, hypohydration, and hyperhydration on tolerance during uncompensable heat stress. Can J Appl Physiol. 1999;24: 349-361
    • (1999) Can J Appl Physiol , vol.24 , pp. 349-361
    • McLellan, T.M.1    Cheung, S.S.2    Latzka, W.A.3
  • 17
    • 33947545652 scopus 로고    scopus 로고
    • Emergency duties and deaths from heart disease among firefighters in the United States
    • Kales SN, Soteriades ES, Christophi CA, Christiani DC. Emergency duties and deaths from heart disease among firefighters in the United States. N Engl J Med. 2007;356:1207-1215
    • (2007) N Engl J Med , vol.356 , pp. 1207-1215
    • Kales, S.N.1    Soteriades, E.S.2    Christophi, C.A.3    Christiani, D.C.4
  • 18
    • 38149048399 scopus 로고    scopus 로고
    • Core temperature cooling in healthy volunteers after rapid intravenous infusion of cold and room temperature saline solution
    • Moore TM, Callaway CW, Hostler D. Core temperature cooling in healthy volunteers after rapid intravenous infusion of cold and room temperature saline solution. Ann Emerg Med. 2008;51:153-159
    • (2008) Ann Emerg Med , vol.51 , pp. 153-159
    • Moore, T.M.1    Callaway, C.W.2    Hostler, D.3
  • 20
    • 0027978280 scopus 로고
    • Heat strain with combat clothing worn over a chemical defense (CD) vapor protective layer
    • McLellan TM, Bell DG, Dix JK. Heat strain with combat clothing worn over a chemical defense (CD) vapor protective layer. Aviat Space Environ Med. 1994;65:757-763
    • (1994) Aviat Space Environ Med , vol.65 , pp. 757-763
    • McLellan, T.M.1    Bell, D.G.2    Dix, J.K.3
  • 21
    • 66349132197 scopus 로고    scopus 로고
    • Validity and reliability of devices that assess body temperature during indoor exercise in the heat
    • Ganio MS, Brown CM, Casa DJ, et al. Validity and reliability of devices that assess body temperature during indoor exercise in the heat. J Athl Train. 2009;44:124-135
    • (2009) J Athl Train , vol.44 , pp. 124-135
    • Ganio, M.S.1    Brown, C.M.2    Casa, D.J.3
  • 22
    • 0842263883 scopus 로고    scopus 로고
    • Heat stress while wearing long pants or shorts under firefighting protective clothing
    • McLellan TM, Selkirk GA. Heat stress while wearing long pants or shorts under firefighting protective clothing. Ergonomics. 2004;47:75-90
    • (2004) Ergonomics , vol.47 , pp. 75-90
    • McLellan, T.M.1    Selkirk, G.A.2
  • 23
    • 0033045062 scopus 로고    scopus 로고
    • Impact of a modern firefighting protective uniform on the incidence and severity of burn injuries in New York City firefighters
    • Prezant DJ, Kelly KJ, Malley KS, et al. Impact of a modern firefighting protective uniform on the incidence and severity of burn injuries in New York City firefighters. J Occup Environ Med. 1999;41:469-479
    • (1999) J Occup Environ Med , vol.41 , pp. 469-479
    • Prezant, D.J.1    Kelly, K.J.2    Malley, K.S.3
  • 24
    • 59449084666 scopus 로고    scopus 로고
    • The effect of hyperhydration on physiological and perceived strain during treadmill exercise in personal protective equipment
    • Hostler D, GallagherMJr, Goss FL, et al. The effect of hyperhydration on physiological and perceived strain during treadmill exercise in personal protective equipment. Eur J Appl Physiol. 2009;105:607-613
    • (2009) Eur J Appl Physiol , vol.105 , pp. 607-613
    • Hostler, D.1    Gallagher Jr., M.2    Goss, F.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.