메뉴 건너뛰기




Volumn 45, Issue 9, 2010, Pages 2008-2014

Risk of cross-infection in a hospital ward with downward ventilation

Author keywords

Cross infection; Downward ventilation; Full scale experiments; Hospital ward; Return opening location; Room air distribution

Indexed keywords

CROSS-INFECTION; FULL-SCALE EXPERIMENT; HOSPITAL WARD; HOSPITAL WARDS; ROOM AIR DISTRIBUTION;

EID: 77952582124     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2010.02.017     Document Type: Article
Times cited : (74)

References (24)
  • 1
    • 15744393009 scopus 로고    scopus 로고
    • Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
    • Li Y., Huang X., Yu I.T.S., Wong T.W., Qian H. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong. Indoor Air 2004, 15:83-95.
    • (2004) Indoor Air , vol.15 , pp. 83-95
    • Li, Y.1    Huang, X.2    Yu, I.T.S.3    Wong, T.W.4    Qian, H.5
  • 2
    • 5444243089 scopus 로고    scopus 로고
    • Predicting super spreading events during the 2003 SARS epidemics in Hong Kong and Singapore
    • Li Y., Yu I.T.S., Xu P., Lee J.H.W., Wong T.W., Ooi P.P., et al. Predicting super spreading events during the 2003 SARS epidemics in Hong Kong and Singapore. American Journal of Epidemiology 2004, 160:719-728.
    • (2004) American Journal of Epidemiology , vol.160 , pp. 719-728
    • Li, Y.1    Yu, I.T.S.2    Xu, P.3    Lee, J.H.W.4    Wong, T.W.5    Ooi, P.P.6
  • 3
    • 77952582459 scopus 로고    scopus 로고
    • Predicting spatial distribution of infection risk of airborne transmission diseases in a hospital ward. In: Proceedings of healthy buildings 2007, Lisboa, Portugal, ISBN: 9789899506718.
    • Qian H, Li Y, Nielsen PV, Huang X. Predicting spatial distribution of infection risk of airborne transmission diseases in a hospital ward. In: Proceedings of healthy buildings 2007, Lisboa, Portugal, ISBN: 9789899506718.
    • Qian, H.1    Li, Y.2    Nielsen, P.V.3    Huang, X.4
  • 4
    • 33846592867 scopus 로고    scopus 로고
    • Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review
    • Li Y., Leung G.M., Tang J.W., Yang X., Chao C.Y.H., Lin J.Z., et al. Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. Indoor Air 2007, 17:2-18.
    • (2007) Indoor Air , vol.17 , pp. 2-18
    • Li, Y.1    Leung, G.M.2    Tang, J.W.3    Yang, X.4    Chao, C.Y.H.5    Lin, J.Z.6
  • 5
    • 77952582613 scopus 로고    scopus 로고
    • Design methods for air distribution systems and comparison between mixing ventilation and displacement ventilation. In: Proceedings of healthy buildings, Singapore.
    • Nielsen PV, Larsen TS, Topp C. Design methods for air distribution systems and comparison between mixing ventilation and displacement ventilation. In: Proceedings of healthy buildings 2003, Singapore.
    • (2003)
    • Nielsen, P.V.1    Larsen, T.S.2    Topp, C.3
  • 6
    • 27644456265 scopus 로고    scopus 로고
    • Air distribution in rooms generated by a textile terminal - comparison with mixing and displacement ventilation
    • Nielsen P.V., Topp C., Soennichsen M., Andersen H. Air distribution in rooms generated by a textile terminal - comparison with mixing and displacement ventilation. ASHRAE Transactions 2005, 111(Part 1):733-739.
    • (2005) ASHRAE Transactions , vol.111 , Issue.PART 1 , pp. 733-739
    • Nielsen, P.V.1    Topp, C.2    Soennichsen, M.3    Andersen, H.4
  • 7
    • 33750308587 scopus 로고    scopus 로고
    • Air distribution in a room with ceiling-mounted diffusers - comparison with wall-mounted diffuser, vertical ventilation and displacement ventilation
    • Nielsen P.V., Heby T., Moeller-Jensen B. Air distribution in a room with ceiling-mounted diffusers - comparison with wall-mounted diffuser, vertical ventilation and displacement ventilation. ASHRAE Transactions 2006.
    • (2006) ASHRAE Transactions
    • Nielsen, P.V.1    Heby, T.2    Moeller-Jensen, B.3
  • 8
    • 77952584133 scopus 로고    scopus 로고
    • Displacement ventilation in non-industrial premises. REHVA guidebook no. 1;
    • Skistad H, Mundt E, Nielsen PV, Hagstroem K, Railio J. Displacement ventilation in non-industrial premises. REHVA guidebook no. 1; 2002.
    • (2002)
    • Skistad, H.1    Mundt, E.2    Nielsen, P.V.3    Hagstroem, K.4    Railio, J.5
  • 9
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    • Bjoern E., Nielsen P.V. Dispersal of exhaled air and personal exposure in displacement ventilated rooms. Indoor Air 2002, 12(3):147-164.
    • (2002) Indoor Air , vol.12 , Issue.3 , pp. 147-164
    • Bjoern, E.1    Nielsen, P.V.2
  • 10
    • 77952584226 scopus 로고    scopus 로고
    • Airflow and contaminant distribution in hospital wards with a displacement ventilation system. In: The 2nd international conference on build environment and public health, BEPH 2004, Shenzhen, China.
    • Qian H, Nielsen PV, Li Y, Hyldgaard CE. Airflow and contaminant distribution in hospital wards with a displacement ventilation system. In: The 2nd international conference on build environment and public health, BEPH 2004, Shenzhen, China.
    • Qian, H.1    Nielsen, P.V.2    Li, Y.3    Hyldgaard, C.E.4
  • 11
    • 34347214433 scopus 로고    scopus 로고
    • Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation
    • Nielsen P.V., Hyldgaard C.E., Melikov A., Andersen H., Soennichsen M. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation. HVAC&R Research 2007, 13(4).
    • (2007) HVAC&R Research , vol.13 , Issue.4
    • Nielsen, P.V.1    Hyldgaard, C.E.2    Melikov, A.3    Andersen, H.4    Soennichsen, M.5
  • 14
    • 33644697163 scopus 로고    scopus 로고
    • Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems
    • Qian H., Li Y., Nielsen P.V., Hyldgaard C.E., Wai Wong T., Chwang A.T.Y. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems. Indoor Air 2006, 16(2):111-128.
    • (2006) Indoor Air , vol.16 , Issue.2 , pp. 111-128
    • Qian, H.1    Li, Y.2    Nielsen, P.V.3    Hyldgaard, C.E.4    Wai Wong, T.5    Chwang, A.T.Y.6
  • 15
    • 77952583902 scopus 로고    scopus 로고
    • Influence of disturbances on bacteria level in an operating room. In: Indoor Air 2008, Paper ID: 665, Copenhagen.
    • Brohus H, Hyldig ML, Kamper S, Vachek UM. Influence of disturbances on bacteria level in an operating room. In: Indoor Air 2008, Paper ID: 665, Copenhagen.
    • Brohus, H.1    Hyldig, M.L.2    Kamper, S.3    Vachek, U.M.4
  • 20
    • 44349096467 scopus 로고    scopus 로고
    • Reducing risk of airborne transmitted infection in hospitals by use of hospital curtains
    • Ching W.H., Leung M.K.H., Leung D.Y.C., Li Y., Yuen P.L. Reducing risk of airborne transmitted infection in hospitals by use of hospital curtains. Indoor and Built Environment 2008, 17:252-259.
    • (2008) Indoor and Built Environment , vol.17 , pp. 252-259
    • Ching, W.H.1    Leung, M.K.H.2    Leung, D.Y.C.3    Li, Y.4    Yuen, P.L.5
  • 21
    • 85029168938 scopus 로고    scopus 로고
    • Health care facilities
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc., Atlanta, Ga., ASHRAE
    • ASHRAE Health care facilities. ASHRAE handbook, HVAC applications, SI edition 2003, American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc., Atlanta, Ga.
    • (2003) ASHRAE handbook, HVAC applications, SI edition
  • 22
    • 77952581718 scopus 로고    scopus 로고
    • Cross infection in a hospital ward and deposition of particles exhaled from a source manikin. In: the third international conference on built environment and public health, Guilin
    • Nielsen PV, Li Y, Buus M, Winther FV, Qian H. Cross infection in a hospital ward and deposition of particles exhaled from a source manikin. In: the third international conference on built environment and public health, Guilin; 2009.
    • (2009)
    • Nielsen, P.V.1    Li, Y.2    Buus, M.3    Winther, F.V.4    Qian, H.5
  • 23
    • 77952581530 scopus 로고    scopus 로고
    • Bed with integrated personalized ventilation for minimizing cross infection. In: Roomvent 2007, 10th international conference on air distribution in rooms, Helsinki
    • Nielsen PV, Jiang H, Polak M. Bed with integrated personalized ventilation for minimizing cross infection. In: Roomvent 2007, 10th international conference on air distribution in rooms, Helsinki; 2007.
    • (2007)
    • Nielsen, P.V.1    Jiang, H.2    Polak, M.3
  • 24
    • 77952580868 scopus 로고    scopus 로고
    • Protection against cross infection in hospital beds with integrated personalized ventilation. In: Indoor Air, Copenhagen.
    • Nielsen PV, Polak M, Jiang H, Li Y, Qian H. Protection against cross infection in hospital beds with integrated personalized ventilation. In: Indoor Air, 2008, Copenhagen.
    • (2008)
    • Nielsen, P.V.1    Polak, M.2    Jiang, H.3    Li, Y.4    Qian, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.