메뉴 건너뛰기




Volumn 111 PART 1, Issue , 2005, Pages 733-739

Air distribution in rooms generated by a textile terminal - Comparison with mixing and displacement ventilation

Author keywords

[No Author keywords available]

Indexed keywords

AIR DISTRIBUTION; BUOYANCY FORCES; HEAT SOURCES;

EID: 27644456265     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (41)

References (10)
  • 1
    • 0003842304 scopus 로고    scopus 로고
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE. 1997. 1997 ASHRAE Handbook - Fundamentals. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1997) 1997 ASHRAE Handbook - Fundamentals
  • 2
    • 0012067547 scopus 로고
    • Interinvidual differences in ambient temperature preferred by seated persons
    • Fanger, P.O., and G. Langkilde. 1975. Interinvidual differences in ambient temperature preferred by seated persons. ASHRAE Transactions 81(2):140-47.
    • (1975) ASHRAE Transactions , vol.81 , Issue.2 , pp. 140-147
    • Fanger, P.O.1    Langkilde, G.2
  • 4
    • 0036459794 scopus 로고    scopus 로고
    • Thermal comfort in a mixing ventilated room with high velocities near the occupied zone
    • Jacobsen, T.S., P.V. Nielsen, R. Hansen, E. Mathiesen, and C. Topp. 2002. Thermal comfort in a mixing ventilated room with high velocities near the occupied zone. ASHRAE Transactions 108(2).
    • (2002) ASHRAE Transactions , vol.108 , Issue.2
    • Jacobsen, T.S.1    Nielsen, P.V.2    Hansen, R.3    Mathiesen, E.4    Topp, C.5
  • 5
    • 0033879045 scopus 로고    scopus 로고
    • Velocity distribution in a room ventilated by displacement ventilation and wall-mounted air terminal devices
    • Nielsen, P.V. 2000. Velocity distribution in a room ventilated by displacement ventilation and wall-mounted air terminal devices. Energy and Buildings. Vol. 31/3, pp. 179-187.
    • (2000) Energy and Buildings , vol.31 , Issue.3 , pp. 179-187
    • Nielsen, P.V.1
  • 6
    • 27644440538 scopus 로고    scopus 로고
    • Design methods for air distribution systems and comparison between mixing ventilation and displacement ventilation
    • 2003
    • Nielsen, P.V., T.S. Larsen, and C. Topp. 2003. Design methods for air distribution systems and comparison between mixing ventilation and displacement ventilation. Proceedings of Healthy Buildings 2003, Singapore, 2003.
    • (2003) Proceedings of Healthy Buildings 2003, Singapore
    • Nielsen, P.V.1    Larsen, T.S.2    Topp, C.3
  • 7
    • 0012033837 scopus 로고
    • Vertical air temperature differences and comfort
    • P.O. Fanger and O. Valbjoern, eds. Danish Building Research Institute, Copenhagen
    • Olesen, B.W., M. Scholer, and P.O. Fanger. 1979. Vertical air temperature differences and comfort. In Indoor Climate, P.O. Fanger and O. Valbjoern, eds. Danish Building Research Institute, Copenhagen, pp. 561-579.
    • (1979) Indoor Climate , pp. 561-579
    • Olesen, B.W.1    Scholer, M.2    Fanger, P.O.3
  • 10
    • 77953588964 scopus 로고    scopus 로고
    • Effect of airflow direction on human perception of draft
    • Brussels
    • Toftum, J., G. Zhou, and A. Melikov. 1997. Effect of airflow direction on human perception of draft. Clima 2000, Brussels.
    • (1997) Clima 2000
    • Toftum, J.1    Zhou, G.2    Melikov, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.