메뉴 건너뛰기




Volumn 43, Issue 2, 2004, Pages 170-173

Automated counting of white blood cells in synovial fluid

Author keywords

Automated; Leucocytes; Synovial fluid; Sysmex XE 2100

Indexed keywords

ARTICLE; AUTOANALYZER; AUTOMATION; CONTROLLED STUDY; CORRELATION COEFFICIENT; CYTOMETRY; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; HEPARINIZATION; HUMAN; INTERMETHOD COMPARISON; KNEE ARTHRITIS; LEUKOCYTE COUNT; MICROSCOPE; OBSERVER VARIATION; PRIORITY JOURNAL; REFERENCE VALUE; SYNOVIAL FLUID;

EID: 1242342215     PISSN: 14620324     EISSN: None     Source Type: Journal    
DOI: 10.1093/rheumatology/keh021     Document Type: Article
Times cited : (50)

References (15)
  • 1
    • 0035664397 scopus 로고    scopus 로고
    • The basis of the synovial fluid analysis
    • Tercic D, Bozic B. The basis of the synovial fluid analysis. Clin Chem Lab Med 2001;39:1221-6.
    • (2001) Clin. Chem. Lab. Med. , vol.39 , pp. 1221-1226
    • Tercic, D.1    Bozic, B.2
  • 2
    • 0036092480 scopus 로고    scopus 로고
    • The value of synovial fluid assays in the diagnosis of joint disease: A literature survey
    • Swan A, Amer H, Dieppe P. The value of synovial fluid assays in the diagnosis of joint disease: a literature survey. Ann Rheum Dis 2002;61:493-8.
    • (2002) Ann. Rheum. Dis. , vol.61 , pp. 493-498
    • Swan, A.1    Amer, H.2    Dieppe, P.3
  • 3
    • 0036169930 scopus 로고    scopus 로고
    • Guidelines for the management of rheumatoid arthritis: 2002 update
    • American College of Rheumatology Subcommittee on Rheumatoid Arthritis
    • American College of Rheumatology Subcommittee on Rheumatoid Arthritis. Guidelines for the management of rheumatoid arthritis: 2002 update. Arthritis Rheum 2002;46:328-46.
    • (2002) Arthritis Rheum. , vol.46 , pp. 328-346
  • 5
    • 0025969690 scopus 로고
    • Diagnostic value of synovial fluid microscopy: A reassessment and rationalisation
    • Freemont AJ, Denton J, Chuck A, Holt PJ, Davies M. Diagnostic value of synovial fluid microscopy: a reassessment and rationalisation. Ann Rheum Dis 1991;50:101-7.
    • (1991) Ann. Rheum. Dis. , vol.50 , pp. 101-107
    • Freemont, A.J.1    Denton, J.2    Chuck, A.3    Holt, P.J.4    Davies, M.5
  • 6
    • 0032551141 scopus 로고    scopus 로고
    • Simple tests for septic bursitis: Comparative study
    • Stell IM, Gransden WR. Simple tests for septic bursitis: comparative study. BMJ 1998;316:1877.
    • (1998) BMJ , vol.316 , pp. 1877
    • Stell, I.M.1    Gransden, W.R.2
  • 7
    • 0022628124 scopus 로고
    • Reproducibility of synovial fluid analyses. A study among four laboratories
    • Schumacher HR Jr, Sieck MS, Rothfuss S et al. Reproducibility of synovial fluid analyses. A study among four laboratories. Arthritis Rheum 1986;29:770-4.
    • (1986) Arthritis Rheum. , vol.29 , pp. 770-774
    • Schumacher Jr., H.R.1    Sieck, M.S.2    Rothfuss, S.3
  • 8
    • 0023236212 scopus 로고
    • Variation in synovial fluid analysis by hospital laboratories
    • Hasselbacher P. Variation in synovial fluid analysis by hospital laboratories. Arthritis Rheum 1987;30:637-42.
    • (1987) Arthritis Rheum. , vol.30 , pp. 637-642
    • Hasselbacher, P.1
  • 11
    • 0021630150 scopus 로고
    • Methods of assessing the synovial fluid cell count
    • Haskard DO, Revell PA. Methods of assessing the synovial fluid cell count. Clin Rheumatol 1984;3:319-22.
    • (1984) Clin. Rheumatol. , vol.3 , pp. 319-322
    • Haskard, D.O.1    Revell, P.A.2
  • 12
    • 0022694120 scopus 로고
    • A comparison of manual and electronic counting for total nucleated cell counts on synovial fluid from canine stifle joints
    • Atilola MA, Lumsden JH, Rooke F. A comparison of manual and electronic counting for total nucleated cell counts on synovial fluid from canine stifle joints. Can J Vet Res 1986;50:282-4.
    • (1986) Can. J. Vet. Res. , vol.50 , pp. 282-284
    • Atilola, M.A.1    Lumsden, J.H.2    Rooke, F.3
  • 13
    • 0030771145 scopus 로고    scopus 로고
    • Comparison of manual and automated cell counts in EDTA preserved synovial fluids. Storage has little influence on the results
    • Salinas M, Rosas J, Iborra J, Manero H, Pascual E. Comparison of manual and automated cell counts in EDTA preserved synovial fluids. Storage has little influence on the results. Ann Rheum Dis 1997;56:622-6.
    • (1997) Ann. Rheum. Dis. , vol.56 , pp. 622-626
    • Salinas, M.1    Rosas, J.2    Iborra, J.3    Manero, H.4    Pascual, E.5
  • 14
    • 0015904006 scopus 로고
    • Rapid, simple detection of trace amounts of synovial fluid
    • Goldenberg DL, Brandt KD, Cohen AS. Rapid, simple detection of trace amounts of synovial fluid. Arthritis Rheum 1973;16: 487-90.
    • (1973) Arthritis Rheum. , vol.16 , pp. 487-490
    • Goldenberg, D.L.1    Brandt, K.D.2    Cohen, A.S.3
  • 15
    • 0034800037 scopus 로고    scopus 로고
    • The utilization of synovial fluid analysis in the UK
    • Amer H, Swan A, Dieppe P. The utilization of synovial fluid analysis in the UK. Rheumatology 2001;40:1060-3.
    • (2001) Rheumatology , vol.40 , pp. 1060-1063
    • Amer, H.1    Swan, A.2    Dieppe, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.