메뉴 건너뛰기




Volumn 37, Issue 5, 2010, Pages 2247-2255

Dose mapping of the rectal wall during brachytherapy with an array of scintillation dosimeters

Author keywords

Brachytherapy; Fiber optic; Rectal array; Scintillation dosimetry

Indexed keywords

ACCIDENTS; APPLICATORS; CCD CAMERAS; DOSIMETERS; FIBER OPTICS; MAPPING; ONCOLOGY; PIXELS; QUALITY ASSURANCE; RADIOTHERAPY; SCINTILLATION; UNCERTAINTY ANALYSIS;

EID: 77952390957     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3397446     Document Type: Article
Times cited : (40)

References (25)
  • 1
    • 85027227859 scopus 로고    scopus 로고
    • Cancer in New South Wales: Incidence and Mortality 2006 (Sydney)
    • E. Tracey, N. Alam, W. Chen, and J. Bishop, Cancer in New South Wales: Incidence and Mortality 2006 (Sydney, 2008).
    • (2008)
    • Tracey, E.1    Alam, N.2    Chen, W.3    Bishop, J.4
  • 2
    • 0034268588 scopus 로고    scopus 로고
    • External beam radiotherapy dose response characteristics of 1127 men with prostate cancer treated in the PSA era
    • IOBPD3 0360-3016. 10.1016/S0360-3016(00)00620-9
    • A. Pollack, L. G. Smith, and A. C. von Eschenbach, " External beam radiotherapy dose response characteristics of 1127 men with prostate cancer treated in the PSA era.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 48, 507-512 (2000). 10.1016/S0360-3016(00)00620-9
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.48 , pp. 507-512
    • Pollack, A.1    Smith, L.G.2    Von Eschenbach, A.C.3
  • 5
    • 0033026882 scopus 로고    scopus 로고
    • What is the alpha/beta ratio for prostate cancer? Rationale for hypofractionated high-dose-rate brachytherapy
    • IOBPD3 0360-3016
    • G. M. Duchesne and L. J. Peters, " What is the alpha/beta ratio for prostate cancer? Rationale for hypofractionated high-dose-rate brachytherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 44, 747-748 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.44 , pp. 747-748
    • Duchesne, G.M.1    Peters, L.J.2
  • 6
    • 0028969271 scopus 로고
    • Toxicity criteria of the Radiation Therapy Oncology Group (RTOG) and the European Organization for Research and Treatment of Cancer (EORTC)
    • IOBPD3 0360-3016. 10.1016/0360-3016(95)00060-C
    • J. D. Cox, J. Stetz, and T. F. Pajak, " Toxicity criteria of the Radiation Therapy Oncology Group (RTOG) and the European Organization for Research and Treatment of Cancer (EORTC).," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 31, 1341-1346 (1995). 10.1016/0360-3016(95)00060-C
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.31 , pp. 1341-1346
    • Cox, J.D.1    Stetz, J.2    Pajak, T.F.3
  • 7
    • 42949126572 scopus 로고    scopus 로고
    • Dosimetric and anatomic indicators of late rectal toxicity after high-dose intensity modulated radiation therapy for prostate cancer
    • DOI 10.1118/1.2907707
    • R. Munbodh, A. Jackson, J. Bauer, C. R. Schmidtlein, and M. J. Zelefsky, " Dosimetric and anatomic indicators of late rectal toxicity after high-dose intensity modulated radiation therapy for prostate cancer.," Med. Phys. MPHYA6 0094-2405 35, 2137-2150 (2008). 10.1118/1.2907707 (Pubitemid 351614828)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 2137-2150
    • Munbodh, R.1    Jackson, A.2    Bauer, J.3    Ross Schmidtlein, C.4    Zelefsky, M.J.5
  • 8
    • 14844302796 scopus 로고    scopus 로고
    • Gastrointestinal toxicity and its relation to dose distributions in the anorectal region of prostate cancer patients treated with radiotherapy
    • IOBPD3 0360-3016. 10.1016/j.ijrob2004.07.724
    • W. D. Heemsbergen, M. S. Hoogeman, G. A. Hart, J. V. Lebesque, and P. C. Koper, " Gastrointestinal toxicity and its relation to dose distributions in the anorectal region of prostate cancer patients treated with radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 61, 1011-1018 (2005). 10.1016/j.ijrobp.2004.07.724
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , pp. 1011-1018
    • Heemsbergen, W.D.1    Hoogeman, M.S.2    Hart, G.A.3    Lebesque, J.V.4    Koper, P.C.5
  • 9
    • 33644828582 scopus 로고    scopus 로고
    • Prevention of high-dose-rate brachytherapy accidents. ICRP Publication 97
    • ZZZZZZ 0146-6453. 10.1016/j.icr2005.05.002
    • J. Valentin, " Prevention of high-dose-rate brachytherapy accidents. ICRP Publication 97.," Ann. ICRP ZZZZZZ 0146-6453 35, 1-51 (2005). 10.1016/j.icrp.2005.05.002
    • (2005) Ann. ICRP , vol.35 , pp. 1-51
    • Valentin, J.1
  • 10
    • 0042674083 scopus 로고    scopus 로고
    • High dose-rate brachytherapy source localization: Positional resolution using a diamond detector
    • DOI 10.1088/0031-9155/48/14/307, PII S0031915503602940
    • T. Nakano, N. Suchowerska, M. M. Bilek, D. R. McKenzie, N. Ng, and T. Kron, " High dose-rate brachytherapy source localization: Positional resolution using a diamond detector.," Phys. Med. Biol. PHMBA7 0031-9155 48, 2133-2146 (2003). 10.1088/0031-9155/48/14/307 (Pubitemid 36926705)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.14 , pp. 2133-2146
    • Nakano, T.1    Suchowerska, N.2    Bilek, M.M.3    McKenzie, D.R.4    Ng, N.5    Kron, T.6
  • 11
    • 13644263150 scopus 로고    scopus 로고
    • Real-time verification of HDR brachytherapy source location: Implementation of detector redundancy
    • DOI 10.1088/0031-9155/50/2/010
    • T. Nakano, N. Suchowerska, D. R. McKenzie, and M. M. Bilek, " Real-time verification of HDR brachytherapy source location: Implementation of detector redundancy.," Phys. Med. Biol. PHMBA7 0031-9155 50, 319-327 (2005). 10.1088/0031-9155/50/2/010 (Pubitemid 40227627)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.2 , pp. 319-327
    • Nakano, T.1    Suchowerska, N.2    McKenzie, D.R.3    Bilek, M.M.4
  • 12
    • 33646165869 scopus 로고    scopus 로고
    • Geometric stability of intracavitary pulsed dose rate brachytherapy monitored by in vivo rectal dosimetry
    • RAONDT 0167-8140. 10.1016/j.radonc.2006.02.016
    • K. Tanderup, J. J. Christensen, J. Granfeldt, and J. C. Lindegaard, " Geometric stability of intracavitary pulsed dose rate brachytherapy monitored by in vivo rectal dosimetry.," Radiother. Oncol. RAONDT 0167-8140 79, 87-93 (2006). 10.1016/j.radonc.2006.02.016
    • (2006) Radiother. Oncol. , vol.79 , pp. 87-93
    • Tanderup, K.1    Christensen, J.J.2    Granfeldt, J.3    Lindegaard, J.C.4
  • 13
    • 85027231423 scopus 로고    scopus 로고
    • Scanditronix, 3G- pSi in vivo detectors
    • Scanditronix, 3G- pSi in vivo detectors (2002).
    • (2002)
  • 14
    • 28944443904 scopus 로고    scopus 로고
    • In-vivo dosimetry for gynaecological brachytherapy: Physical and clinical considerations
    • DOI 10.1016/j.radonc.2005.09.004, PII S0167814005003907
    • C. Waldhäusl, A. Wambersie, R. Pötter, and D. Georg, " In-vivo dosimetry for gynaecological brachytherapy: Physical and clinical considerations.," Radiother. Oncol. RAONDT 0167-8140 77, 310-317 (2005). 10.1016/j.radonc.2005.09.004 (Pubitemid 41785342)
    • (2005) Radiotherapy and Oncology , vol.77 , Issue.3 , pp. 310-317
    • Waldhausl, C.1    Wambersie, A.2    Potter, R.3    Georg, D.4
  • 15
    • 33751168473 scopus 로고    scopus 로고
    • A plastic scintillation dosimeter for high dose rate brachytherapy
    • DOI 10.1088/0031-9155/51/21/008, PII S0031915506261293, 008
    • J. Lambert, D. R. McKenzie, S. Law, J. Elsey, and N. Suchowerska, " A plastic scintillation dosimeter for high dose rate brachytherapy.," Phys. Med. Biol. PHMBA7 0031-9155 51, 5505-5516 (2006). 10.1088/0031-9155/51/21/008 (Pubitemid 44773328)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.21 , pp. 5505-5516
    • Lambert, J.1    McKenzie, D.R.2    Law, S.3    Elsey, J.4    Suchowerska, N.5
  • 16
    • 34247629705 scopus 로고    scopus 로고
    • Water-equivalent dosimeter array for small-field external beam radiotherapy
    • DOI 10.1118/1.2719363
    • L. Archambault, A. S. Beddar, L. Gingras, F. Lacroix, R. Roy, and L. Beaulieu, " Water-equivalent dosimeter array for small-field external beam radiotherapy.," Med. Phys. MPHYA6 0094-2405 34, 1583-1592 (2007). 10.1118/1.2719363 (Pubitemid 46669155)
    • (2007) Medical Physics , vol.34 , Issue.5 , pp. 1583-1592
    • Archambault, L.1    Beddar, A.S.2    Gingras, L.3    Lacroix, F.4    Roy, R.5    Beaulieu, L.6
  • 17
    • 48349136774 scopus 로고    scopus 로고
    • Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications
    • MPHYA6 0094-2405. 10.1118/1.2953564
    • F. Lacroix, L. Archambault, L. Gingras, M. Guillot, A. S. Beddar, and L. Beaulieu, " Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications.," Med. Phys. MPHYA6 0094-2405 35, 3682-3690 (2008). 10.1118/1.2953564
    • (2008) Med. Phys. , vol.35 , pp. 3682-3690
    • Lacroix, F.1    Archambault, L.2    Gingras, L.3    Guillot, M.4    Beddar, A.S.5    Beaulieu, L.6
  • 19
    • 31044441579 scopus 로고    scopus 로고
    • Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry
    • DOI 10.1118/1.2138010
    • L. Archambault, A. S. Beddar, L. Gingras, R. Roy, and L. Beaulieu, " Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry.," Med. Phys. MPHYA6 0094-2405 33, 128-135 (2006). 10.1118/1.2138010 (Pubitemid 43121042)
    • (2006) Medical Physics , vol.33 , Issue.1 , pp. 128-135
    • Archambault, L.1    Sam Beddar, A.2    Gingras, L.3    Roy, R.4    Beaulieu, L.5
  • 20
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators - The general concept and applications to ophthalmic plaque dosimetry
    • DOI 10.1118/1.597736
    • D. Flühs, M. Heintz, F. Indenkämpen, and C. Wieczorek, " Direct reading measurement of absorbed dose with plastic scintillators-The general concept and applications to ophthalmic plaque dosimetry.," Med. Phys. MPHYA6 0094-2405 23, 427-434 (1996). 10.1118/1.597736 (Pubitemid 26095699)
    • (1996) Medical Physics , vol.23 , Issue.3 , pp. 427-434
    • Fluhs, D.1    Heintz, M.2    Indenkampen, F.3    Wieczorek, C.4    Kolanoski, H.5    Quast, U.6
  • 21
    • 0030168994 scopus 로고    scopus 로고
    • Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry
    • IETNAE 0018-9499. 10.1109/23.502302
    • M. R. Arnfield, H. E. Gaballa, R. D. Zwicker, Q. Islam, and R. Schmidt-Ullrich, " Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry.," IEEE Trans. Nucl. Sci. IETNAE 0018-9499 43, 2077-2084 (1996). 10.1109/23.502302
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 2077-2084
    • Arnfield, M.R.1    Gaballa, H.E.2    Zwicker, R.D.3    Islam, Q.4    Schmidt-Ullrich, R.5
  • 22
    • 22544444219 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators
    • DOI 10.1118/1.1943807
    • L. Archambault, J. Arsenault, L. Gingras, A. S. Beddar, R. Roy, and L. Beaulieu, " Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators.," Med. Phys. MPHYA6 0094-2405 32, 2271-2278 (2005). 10.1118/1.1943807 (Pubitemid 41023185)
    • (2005) Medical Physics , vol.32 , Issue.7 , pp. 2271-2278
    • Archambault, L.1    Arsenault, J.2    Gingras, L.3    Beddar, A.S.4    Roy, R.5    Beaulieu, L.6
  • 23
    • 45749136904 scopus 로고    scopus 로고
    • Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide
    • DOI 10.1088/0031-9155/53/11/021, PII S0031915508750449
    • J. Lambert, Y. Yin, D. R. McKenzie, S. Law, and N. Suchowerska, " Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.," Phys. Med. Biol. PHMBA7 0031-9155 53, 3071-3080 (2008). 10.1088/0031-9155/53/11/021 (Pubitemid 351868624)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 3071-3080
    • Lambert, J.1    Yin, Y.2    McKenzie, D.R.3    Law, S.4    Suchowerska, N.5
  • 24
    • 0043175225 scopus 로고    scopus 로고
    • The noise performance of electron multiplying charge-coupled devices
    • IETDAI 0018-9383. 10.1109/TED.2003.813462
    • M. S. Robbins and B. J. Hadwen, " The noise performance of electron multiplying charge-coupled devices.," IEEE Trans. Electron Devices IETDAI 0018-9383 50, 1227-1232 (2003). 10.1109/TED.2003.813462
    • (2003) IEEE Trans. Electron Devices , vol.50 , pp. 1227-1232
    • Robbins, M.S.1    Hadwen, B.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.