메뉴 건너뛰기




Volumn 37, Issue 2, 2010, Pages 224-229

Development of protein quantification based on ICP-MS

Author keywords

Inductively coupled plasma mass spectrometry (icp ms); Protein quantification; Proteomics; Rareearth elemental labeling

Indexed keywords


EID: 77952029829     PISSN: 10003282     EISSN: None     Source Type: Journal    
DOI: 10.3724/SP.J.1206.2009.00498     Document Type: Article
Times cited : (7)

References (30)
  • 1
    • 2642569251 scopus 로고    scopus 로고
    • Absolute quantification of proteins in solutions and in polyacrylamide gels by mass spectrometry
    • DOI 10.1021/ac035286f
    • Havlis J, Shevchenko A. Absolute quantification of proteins in solutions and in Polyacrylamide gels by mass spectrometry. Anal Chem, 2004, 76 (11): 3029-3036 (Pubitemid 38715692)
    • (2004) Analytical Chemistry , vol.76 , Issue.11 , pp. 3029-3036
    • Havlis, J.1    Shevchenko, A.2
  • 2
    • 4444301306 scopus 로고    scopus 로고
    • Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-Ms/MS using protein cleavage and isotope dilution mass spectrometry
    • Barnidge D R, Goodmanson M K, Klee G G, el al. Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-Ms/MS using protein cleavage and isotope dilution mass spectrometry. J Proteome Res, 2004, 3 (3): 644-652
    • (2004) J Proteome Res , vol.3 , Issue.3 , pp. 644-652
    • Barnidge, D.R.1    Goodmanson, M.K.2    Klee, G.G.3
  • 3
    • 0034213695 scopus 로고    scopus 로고
    • Reduction of space charge effects in inductively coupled plasma mass spectrometry using a supplemental electron source inside the skimmer: Ion transmission and mass spectral characteristics
    • DOI 10.1021/ac000159u
    • Praphairaksit N, Houk R S. Reduction of space charge effects in inductively coupled plasma mass spectrometry using a supplemental electron source inside the skimmer: ion transmission and mass spectral characteristics. Anal Chem, 2000, 72(11): 2356-2361 (Pubitemid 30395632)
    • (2000) Analytical Chemistry , vol.72 , Issue.11 , pp. 2356-2361
    • Praphairaksit, N.1    Houk, R.S.2
  • 4
    • 0034213694 scopus 로고    scopus 로고
    • Attenuation of matrix effects in inductively coupled plasma mass spectrometry with a supplemental electron source inside the skimmer
    • DOI 10.1021/ac000150s
    • Praphairaksit N, Houk R S. Reduction of mass bias and matrix effects in inductively coupled plasma mass spectrometry with a supplemental electron source in a negative extraction lens. Anal Chem, 2000, 72 (18): 4435-4440 (Pubitemid 30395631)
    • (2000) Analytical Chemistry , vol.72 , Issue.11 , pp. 2351-2355
    • Praphairaksit, N.1    Houk, R.S.2
  • 5
    • 0034926188 scopus 로고    scopus 로고
    • Speciation of essential elements in human serum using anion-exchange chromatography coupled to post-column isotope dilution analysis with double focusing ICP-MS
    • Muñiz C S, Gayón J M M, Alonso J I G, el al. Speciation of essential elements in human serum using anion-exchange chromatography coupled to post-column isotope dilution analysis with double focusing ICP-MS. J Analytical Atomic Spectrometry, 2001,16 (6): 587-592
    • (2001) J Analytical Atomic Spectrometry , vol.16 , Issue.6 , pp. 587-592
    • Muñiz, C.S.1    Gayón, J.M.M.2    Alonso, J.I.G.3
  • 6
    • 0036535150 scopus 로고    scopus 로고
    • A sensitive and quantitative element-tagged immunoassay with ICPMS detection
    • Baranov V I, Quinn Z, Bandura D R, el al. A sensitive and quantitative element-tagged immunoassay with ICPMS detection. Anal Chem, 2002, 74 (7): 1629-1636
    • (2002) Anal Chem , vol.74 , Issue.7 , pp. 1629-1636
    • Baranov, V.I.1    Quinn, Z.2    Bandura, D.R.3
  • 7
    • 0033956343 scopus 로고    scopus 로고
    • Speciation of proteinbinding zinc and copper in human blood serum by chelating resin pre-treatment and inductively coupled plasma mass spectrometry
    • Inagaki K, Mikuriya N, Morita S, el al. Speciation of proteinbinding zinc and copper in human blood serum by chelating resin pre-treatment and inductively coupled plasma mass spectrometry. Analyst, 2000, 125 (1): 197-203
    • (2000) Analyst , vol.125 , Issue.1 , pp. 197-203
    • Inagaki, K.1    Mikuriya, N.2    Morita, S.3
  • 8
    • 0035166087 scopus 로고    scopus 로고
    • Measurement of trace elements in proteins extracted from liver by size exclusion chromatography-inductively coupled plasma-mass spectrometry with a magnetic sector mass spectrometer
    • Wang J, Dreessen D, Wiederin D R, el al. Measurement of trace elements in proteins extracted from liver by size exclusion chromatography-inductively coupled plasma-mass spectrometry with a magnetic sector mass spectrometer. Anal Biochem, 2001, 288 (1): 89-96
    • (2001) Anal Biochem , vol.288 , Issue.1 , pp. 89-96
    • Wang, J.1    Dreessen, D.2    Wiederin, D.R.3
  • 9
    • 21644441740 scopus 로고    scopus 로고
    • Potential for using isotopically altered metalloproteins in species-specific isotope dilution analysis of proteins by HPLC coupled to inductively coupled plasma mass spectrometry
    • Harrington C F, Vidler D S, Watts M J, el al. Potential for using isotopically altered metalloproteins in species-specific isotope dilution analysis of proteins by HPLC coupled to inductively coupled plasma mass spectrometry. Anal Chem, 2005, 77(13): 4034-4041
    • (2005) Anal Chem , vol.77 , Issue.13 , pp. 4034-4041
    • Harrington, C.F.1    Vidler, D.S.2    Watts, M.J.3
  • 11
    • 59949092209 scopus 로고    scopus 로고
    • Progress in the detection of seleniumcontaining trace proteins
    • Liu Q, Peng Z, Liang X Y. Progress in the detection of seleniumcontaining trace proteins. Spectroscopy and Spectral Analysis, 2009, 29 (2): 530-535
    • (2009) Spectroscopy and Spectral Analysis , vol.29 , Issue.2 , pp. 530-535
    • Liu, Q.1    Peng, Z.2    Liang, X.Y.3
  • 12
    • 3142718965 scopus 로고    scopus 로고
    • Selenium and selenomethionine levels in prostate cancer patients
    • Nyman D W, Suzanne Stratton M, Kopplin M J, el al. Selenium and selenomethionine levels in prostate cancer patients. Cancer Detect Prev, 2004, 28 (1): 8-16
    • (2004) Cancer Detect Prev , vol.28 , Issue.1 , pp. 8-16
    • Nyman, D.W.1    Suzanne Stratton, M.2    Kopplin, M.J.3
  • 13
    • 8644233434 scopus 로고    scopus 로고
    • Determination of selenomethionine and selenocysteine in human serum using speciated isotope dilution-capillary HPLC-inductively coupled plasma collision cell mass spectrometry
    • Encinar J R, Schaumloffel D, Ogra Y, el al. Determination of selenomethionine and selenocysteine in human serum using speciated isotope dilution-capillary HPLC-inductively coupled plasma collision cell mass spectrometry. Anal Chem, 2004, 76 (22): 6635-6642
    • (2004) Anal Chem , vol.76 , Issue.22 , pp. 6635-6642
    • Encinar, J.R.1    Schaumloffel, D.2    Ogra, Y.3
  • 14
    • 33847420645 scopus 로고    scopus 로고
    • Capillary HPLC-ICP MS mapping of selenocompounds in spots obtained from the 2-D gel electrophoresis of the water-soluble protein fraction of selenized yeast
    • Tastet L, Schaumloffel D, Bouyssiere B, el al. Capillary HPLC-ICP MS mapping of selenocompounds in spots obtained from the 2-D gel electrophoresis of the water-soluble protein fraction of selenized yeast. Anal Bioanal Chem, 2006, 385 (5): 948-953
    • (2006) Anal Bioanal Chem , vol.385 , Issue.5 , pp. 948-953
    • Tastet, L.1    Schaumloffel, D.2    Bouyssiere, B.3
  • 16
    • 0042029679 scopus 로고    scopus 로고
    • Sulfur as the key element for quantitative protein analysis by capillary liquid chromatography coupled to element mass spectrometry
    • Wind M, Wegener A, Eisenmenger A, el al. Sulfur as the key element for quantitative protein analysis by capillary liquid chromatography coupled to element mass spectrometry. Angew Chem Int Ed Engl, 2003, 42 (29): 3425-3427
    • (2003) Angew Chem Int Ed Engl , vol.42 , Issue.29 , pp. 3425-3427
    • Wind, M.1    Wegener, A.2    Eisenmenger, A.3
  • 17
    • 37749006199 scopus 로고    scopus 로고
    • The role of sulfur and sulfur isotope dilution analysis in quantitative protein analysis
    • Rappel C, Schaumloffel D. The role of sulfur and sulfur isotope dilution analysis in quantitative protein analysis. Anal Bioanal Chem, 2008, 390 (2): 605-615
    • (2008) Anal Bioanal Chem , vol.390 , Issue.2 , pp. 605-615
    • Rappel, C.1    Schaumloffel, D.2
  • 18
    • 1042284932 scopus 로고    scopus 로고
    • Protein profiling with cleavable isotopecoded affinity tag (cICAT) reagents: The yeast salinity stress response
    • Li J, Steen H, Gygi S P. Protein profiling with cleavable isotopecoded affinity tag (cICAT) reagents: the yeast salinity stress response. Mol Cell Proteomics, 2003, 2 (11): 1198-1204
    • (2003) Mol Cell Proteomics , vol.2 , Issue.11 , pp. 1198-1204
    • Li, J.1    Steen, H.2    Gygi, S.P.3
  • 19
    • 33847174067 scopus 로고    scopus 로고
    • Protein labeling by iTRAQ: A new tool for quantitative mass spectrometry in proteome research
    • Wiese S, Reidegeld K A, Meyer H E, el al. Protein labeling by iTRAQ: a new tool for quantitative mass spectrometry in proteome research. Proteomics, 2007, 7 (3): 340-350
    • (2007) Proteomics , vol.7 , Issue.3 , pp. 340-350
    • Wiese, S.1    Reidegeld, K.A.2    Meyer, H.E.3
  • 20
    • 0034577528 scopus 로고    scopus 로고
    • High resolution inductively coupled plasma mass spectrometry (HR-ICPMS) determination and multivariate evaluation of 10 trace elements in mussels from 7 sites in Limfjorden, Denmark
    • Bechmann I E, Sturup S, Kristensen L V. High resolution inductively coupled plasma mass spectrometry (HR-ICPMS) determination and multivariate evaluation of 10 trace elements in mussels from 7 sites in Limfjorden, Denmark. Fresenius J Anal Chem, 2000, 368 (7): 708-714
    • (2000) Fresenius J Anal Chem , vol.368 , Issue.7 , pp. 708-714
    • Bechmann, I.E.1    Sturup, S.2    Kristensen, L.V.3
  • 21
    • 34247130048 scopus 로고    scopus 로고
    • Precolumn isotope dilution analysis in nanoHPLC-ICPMS for absolute quantification of sulfur-containing peptides
    • DOI 10.1021/ac061864r
    • Schaumlöffel D, Giusti P, Preud'Homme H, et al. Precolumn isotope dilution analysis in nanoHPLC-ICPMS for absolute quantification of sulfur-containing peptides. Anal Chem, 2007, 79 (7): 2859-2868 (Pubitemid 46595641)
    • (2007) Analytical Chemistry , vol.79 , Issue.7 , pp. 2859-2868
    • Schaumloffel, D.1    Giusti, P.2    Preud'Homme, H.3    Szpunar, J.4    Lobinski, R.5
  • 22
    • 0036534687 scopus 로고    scopus 로고
    • Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell
    • Bandura D R, Baranov V I, Tanner S D. Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell. Anal Chem, 2002, 74 (7): 1497-1502
    • (2002) Anal Chem , vol.74 , Issue.7 , pp. 1497-1502
    • Bandura, D.R.1    Baranov, V.I.2    Tanner, S.D.3
  • 23
    • 1342277200 scopus 로고    scopus 로고
    • Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell
    • DOI 10.1007/s00216-003-2041-8
    • Pröfrock D, Leonhard P, Prange A. Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell. Anal Bioanal Chem, 2003, 377(1): 132-139 (Pubitemid 40877897)
    • (2003) Analytical and Bioanalytical Chemistry , vol.377 , Issue.1 , pp. 132-139
    • Profrock, D.1    Leonhard, P.2    Prange, A.3
  • 24
    • 36849010746 scopus 로고    scopus 로고
    • Quantitative analysis of proteins via sulfur determination by HPLC coupled to isotope dilution ICPMS with a hexapole collision cell
    • Wang M, Feng W, Lu W, el al. Quantitative analysis of proteins via sulfur determination by HPLC coupled to isotope dilution ICPMS with a hexapole collision cell. Anal Chem, 2007, 79(23): 9128-9134
    • (2007) Anal Chem , vol.79 , Issue.23 , pp. 9128-9134
    • Wang, M.1    Feng, W.2    Lu, W.3
  • 25
    • 0035387929 scopus 로고    scopus 로고
    • Protein phosphorylation degree: Determination by capillary liquid chromatography and inductively coupled plasma mass spectrometry
    • DOI 10.1021/ac010066s
    • Wind M, Wesch H, Lehmann W D. Protein phosphorylation degree: determination by capillary liquid chromatography and inductively coupled plasma mass spectrometry. Anal Chem, 2001, 73 (13): 3006-3010 (Pubitemid 32868159)
    • (2001) Analytical Chemistry , vol.73 , Issue.13 , pp. 3006-3010
    • Wind, M.1    Wesch, H.2    Lehmann, W.D.3
  • 26
    • 41149098111 scopus 로고    scopus 로고
    • Absolute and site-specific quantification of protein phosphorylation using integrated elemental and molecular mass spectrometry: Its potential to assess phosphopeptide enrichment procedures
    • Navaza A P, Encinar J R, Carrascal M, el al. Absolute and site-specific quantification of protein phosphorylation using integrated elemental and molecular mass spectrometry: its potential to assess phosphopeptide enrichment procedures. Anal Chem, 2008, 80 (5): 1777-1787
    • (2008) Anal Chem , vol.80 , Issue.5 , pp. 1777-1787
    • Navaza, A.P.1    Encinar, J.R.2    Carrascal, M.3
  • 27
    • 0842328433 scopus 로고    scopus 로고
    • Element-coded affinity tags for peptides and proteins
    • Whetstone P A, Butlin N G, Corneillie T M, el al. Element-coded affinity tags for peptides and proteins. Bioconjug Chem, 2004, 15 (1): 3-6
    • (2004) Bioconjug Chem , vol.15 , Issue.1 , pp. 3-6
    • Whetstone, P.A.1    Butlin, N.G.2    Corneillie, T.M.3
  • 28
    • 33748805535 scopus 로고    scopus 로고
    • Method for quantitative proteomics research by using metal element chelated tags coupled with mass spectrometry
    • Liu H, Zhang Y, Wang J, el al. Method for quantitative proteomics research by using metal element chelated tags coupled with mass spectrometry. Anal Chem, 2006, 78 (18): 6614-6621
    • (2006) Anal Chem , vol.78 , Issue.18 , pp. 6614-6621
    • Liu, H.1    Zhang, Y.2    Wang, J.3
  • 29
    • 37549042777 scopus 로고    scopus 로고
    • Isotopic labelling of peptides and isotope ratio analysis using LC-ICP-MS: A preliminary study
    • Patel P, Jones P, Handy R, el al. Isotopic labelling of peptides and isotope ratio analysis using LC-ICP-MS: a preliminary study. Anal Bioanal Chem, 2008, 390 (1): 61-65
    • (2008) Anal Bioanal Chem , vol.390 , Issue.1 , pp. 61-65
    • Patel, P.1    Jones, P.2    Handy, R.3
  • 30
    • 58149470835 scopus 로고    scopus 로고
    • Absolute peptide quantification by lutetium labeling and nanoHPLC-ICPMS with isotope dilution analysis
    • Rappel C, Schaumlöffel D. Absolute peptide quantification by lutetium labeling and nanoHPLC-ICPMS with isotope dilution analysis. Anal Chem, 2009, 81 (1): 385-393
    • (2009) Anal Chem , vol.81 , Issue.1 , pp. 385-393
    • Rappel, C.1    Schaumlöffel, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.