메뉴 건너뛰기




Volumn 11, Issue 6, 2010, Pages 431-439

Evaluation of coronary in-stent restenosis by 64-slice computed tomography in patients with optimal heart rate control by systematic administration of beta-blocker drugs

Author keywords

Coronary artery disease; Coronary stent; Multislice computed tomography

Indexed keywords

ALPRAZOLAM; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; ESMOLOL; IOMEPROL; METOPROLOL; PROPRANOLOL; SODIUM CHLORIDE;

EID: 77951794987     PISSN: 15582027     EISSN: None     Source Type: Journal    
DOI: 10.2459/JCM.0b013e3283330fcd     Document Type: Article
Times cited : (4)

References (29)
  • 1
    • 77951825550 scopus 로고    scopus 로고
    • For Europe: Toronto, Canada: Millennium Research Group, For USA: USMO data plus internal data. California, USA: Abbott Vascular
    • For Europe: MRG data plus internal data. Toronto, Canada: Millennium Research Group, For USA: USMO data plus internal data. California, USA: Abbott Vascular.
    • MRG Data Plus Internal Data
  • 2
    • 25144508347 scopus 로고    scopus 로고
    • Drug eluting stents compared with thin strut bare stents for the reduction of restenosis: A prospective randomized trial
    • Pache J, Dibra A, Mehilli J, Dirscinger J, Schomig A, Kastrati A. Drug eluting stents compared with thin strut bare stents for the reduction of restenosis: a prospective randomized trial. Eur Heart J 2005; 26:1262-1268.
    • (2005) Eur Heart J , vol.26 , pp. 1262-1268
    • Pache, J.1    Dibra, A.2    Mehilli, J.3    Dirscinger, J.4    Schomig, A.5    Kastrati, A.6
  • 4
    • 26844549564 scopus 로고    scopus 로고
    • High resolution spiral computed tomography coronary angiography in patients referred for diagnostic coronary angiography
    • Mollet NR, Cademartiri F, van Mieghem CA, Runza G, McFadden EP, Baks T, et al. High resolution spiral computed tomography coronary angiography in patients referred for diagnostic coronary angiography. Circulation 2005; 112:2318-2323.
    • (2005) Circulation , vol.112 , pp. 2318-2323
    • Mollet, N.R.1    Cademartiri, F.2    Van Mieghem, C.A.3    Runza, G.4    McFadden, E.P.5    Baks, T.6
  • 5
    • 31344439737 scopus 로고    scopus 로고
    • Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease
    • Fine JJ, Hopkins CB, Ruff N, Newton FC. Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease. Am J Cardiol 2006; 97:173-174.
    • (2006) Am J Cardiol , vol.97 , pp. 173-174
    • Fine, J.J.1    Hopkins, C.B.2    Ruff, N.3    Newton, F.C.4
  • 7
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and non obstructive coronary lesions by 64 slice computed tomography. A comparative study with Quantitative coronary angiography and intravascular ultrasound
    • Leber AW, Knez A, von Ziegler F, Becker A, Nikolau F, Paul S, et al. Quantification of obstructive and non obstructive coronary lesions by 64 slice computed tomography. A comparative study with Quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 2005; 46:147-154.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    Von Ziegler, F.3    Becker, A.4    Nikolau, F.5    Paul, S.6
  • 8
    • 46849099432 scopus 로고    scopus 로고
    • Poon. Follow up of patients after percutaneous coronary intervention
    • Budoff M, Achenbach S, Narula J, editors. Berlin: Springer; Chapter 6
    • Chowdhury H, Ahsan D, Bush T, Kondo M, Poon. Follow up of patients after percutaneous coronary intervention. In: Budoff M, Achenbach S, Narula J, editors. Atlas of cardiovascular computed tomography. Berlin: Springer; 2007. p. 85, Chapter 6.
    • (2007) Atlas of Cardiovascular Computed Tomography , pp. 85
    • Chowdhury, H.1    Ahsan, D.2    Bush, T.3    Kondo, M.4
  • 9
    • 77951788260 scopus 로고    scopus 로고
    • Patency control of coronary stents
    • Ohnesorge BM, Flohr TG, Becker CR, Knez A, Reser MF, editors. Berlin: Springer; Chapter 7.7
    • Nieman K, Mollet N, Cademartiri F, De Feyter P. Patency control of coronary stents. In: Ohnesorge BM, Flohr TG, Becker CR, Knez A, Reser MF, editors. Multislice and dual-source CT in cardiac imaging. Berlin: Springer; 2007. p. 239, Chapter 7.7.
    • (2007) Multislice and Dual-source CT in Cardiac Imaging , pp. 239
    • Nieman, K.1    Mollet, N.2    Cademartiri, F.3    De Feyter, P.4
  • 10
    • 27744544089 scopus 로고    scopus 로고
    • Evaluation of coronary stents in vitro with CT angiography: Effect of stent diameter, convolution kernel and vessel orientation to the z axis
    • Suzuki S, Furui S, Kaminaga S, Yamauchi T, Kuwahara S, Yokohama N, et al. Evaluation of coronary stents in vitro with CT angiography: effect of stent diameter, convolution kernel and vessel orientation to the z axis. Circ J 2005; 69:1124-1133.
    • (2005) Circ J , vol.69 , pp. 1124-1133
    • Suzuki, S.1    Furui, S.2    Kaminaga, S.3    Yamauchi, T.4    Kuwahara, S.5    Yokohama, N.6
  • 11
    • 34249708432 scopus 로고    scopus 로고
    • Usefulness of 64 slice multislice computed tomography coronary angiography to assess in-stent restenosis
    • Cademartiri F, Schujf JD, Pugliese F, Mollet N, Jukema W, Maffei E, et al. Usefulness of 64 slice multislice computed tomography coronary angiography to assess in-stent restenosis. J Am Coll Cardiol 2007; 49:2204-2210.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 2204-2210
    • Cademartiri, F.1    Schujf, J.D.2    Pugliese, F.3    Mollet, N.4    Jukema, W.5    Maffei, E.6
  • 13
    • 41349096091 scopus 로고    scopus 로고
    • Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery Disease
    • DOI 10.1016/j.jcmg.2007.11.006, PII S1936878X08000090
    • Achenbach S, Ropers U, Kuettner A, Anders K, Pflederer T, Komatsu S, et al. Randomized comparison of 64-slice single- and dual-source computed tomography coronary angiography for the detection of coronary artery disease. JACC Cardiovasc Imaging 2008; 1:177-186. (Pubitemid 351447183)
    • (2008) JACC: Cardiovascular Imaging , vol.1 , Issue.2 , pp. 177-186
    • Achenbach, S.1    Ropers, U.2    Kuettner, A.3    Anders, K.4    Pflederer, T.5    Komatsu, S.6    Bautz, W.7    Daniel, W.G.8    Ropers, D.9
  • 14
    • 40849146791 scopus 로고    scopus 로고
    • Heart rate-independent dual source computed tomography coronary angiography: Growing experience
    • Ropers D. Heart rate-independent dual source computed tomography coronary angiography: growing experience. J Cardiovasc Comput Tomogr 2008; 2:115-116.
    • (2008) J Cardiovasc Comput Tomogr , vol.2 , pp. 115-116
    • Ropers, D.1
  • 15
    • 40849092923 scopus 로고    scopus 로고
    • Image quality and artifacts in coronary CT angiography with dual source CT: Initial clinical experience
    • Dey D, Lee CJ, Ohba M, Gutstein A, Slomka PJ, Cheng V, et al. Image quality and artifacts in coronary CT angiography with dual source CT: initial clinical experience. J Cardiovasc Comput Tomogr 2008; 2:105-114.
    • (2008) J Cardiovasc Comput Tomogr , vol.2 , pp. 105-114
    • Dey, D.1    Lee, C.J.2    Ohba, M.3    Gutstein, A.4    Slomka, P.J.5    Cheng, V.6
  • 18
    • 33750292412 scopus 로고    scopus 로고
    • Non invasive coronary angiography by 64 section CT: Effect of average heart rate and heart rate variability on image quality
    • Lescha S, Wildermuth S, Boehm T, Desbiolles M, Husman L, Plass A, et al. Non invasive coronary angiography by 64 section CT: effect of average heart rate and heart rate variability on image quality. Radiology 2006; 24:378-385.
    • (2006) Radiology , vol.24 , pp. 378-385
    • Lescha, S.1    Wildermuth, S.2    Boehm, T.3    Desbiolles, M.4    Husman, L.5    Plass, A.6
  • 19
    • 0034867726 scopus 로고    scopus 로고
    • ECG gated reconstruction multi detector row CT coronary angiography: Effects of trigger delay on image quality
    • Hong C, Becker CR, Huber A. ECG gated reconstruction multi detector row CT coronary angiography: effects of trigger delay on image quality. Radiology 2001; 220:712-717.
    • (2001) Radiology , vol.220 , pp. 712-717
    • Hong, C.1    Becker, C.R.2    Huber, A.3
  • 20
    • 43549100418 scopus 로고    scopus 로고
    • Usefulness of 64-detector row computed tomography for evaluation of intracoronary stents in symptomatic patients with suspected in-stent restenosis
    • Manghat N, Van LIngen R, Hewson P, Syed F, Kakani N, Cox I, et al. Usefulness of 64-detector row computed tomography for evaluation of intracoronary stents in symptomatic patients with suspected in-stent restenosis. Am J Cardiol 2008; 101:1567-1573.
    • (2008) Am J Cardiol , vol.101 , pp. 1567-1573
    • Manghat, N.1    Van Lingen, R.2    Hewson, P.3    Syed, F.4    Kakani, N.5    Cox, I.6
  • 27
    • 36749033957 scopus 로고    scopus 로고
    • Prospective gated coronary CT angiography: An evaluation of effective dose and reliability in a large patient group
    • Earls J, Urban B, Berman E, Curry C, Lane J, Jennings R. Prospective gated coronary CT angiography: an evaluation of effective dose and reliability in a large patient group. J Cardiovasc Comput Tomogr 2007; 1:S6.
    • (2007) J Cardiovasc Comput Tomogr , vol.1
    • Earls, J.1    Urban, B.2    Berman, E.3    Curry, C.4    Lane, J.5    Jennings, R.6
  • 28
    • 40849146023 scopus 로고    scopus 로고
    • Latest clinical breakthrough in cardiac CT: Drastic dose reduction with SnapShot pulse mode on light speed VCT XT
    • Sablayrolles JL, Treutenaere JM, Feignoux J, Jardin C. Latest clinical breakthrough in cardiac CT: drastic dose reduction with SnapShot pulse mode on light speed VCT XT. J Cardiovasc Comput Tomogr 2007; 1:S7.
    • (2007) J Cardiovasc Comput Tomogr , vol.1
    • Sablayrolles, J.L.1    Treutenaere, J.M.2    Feignoux, J.3    Jardin, C.4
  • 29
    • 67349168167 scopus 로고    scopus 로고
    • SCCT guidelines for performance of coronary computed tomographic angiography: A report of the Society of Cardiovascular Computed Tomography Guidelines Committee
    • Abbara S, Zadeh A, Callister T, Desai M, Weigold G. SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 2009; 3:190-204.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 190-204
    • Abbara, S.1    Zadeh, A.2    Callister, T.3    Desai, M.4    Weigold, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.