메뉴 건너뛰기




Volumn 49, Issue 9, 2007, Pages 951-959

Diagnostic Accuracy of Coronary In-Stent Restenosis Using 64-Slice Computed Tomography. Comparison With Invasive Coronary Angiography

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ANGIOGRAPHY; ARTERY INTIMA PROLIFERATION; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CORONARY STENT; DIAGNOSTIC ACCURACY; DISEASE SEVERITY; FALSE POSITIVE RESULT; FEMALE; FOLLOW UP; HUMAN; IMAGE RECONSTRUCTION; MAJOR CLINICAL STUDY; MALE; NON INVASIVE MEASUREMENT; PRIORITY JOURNAL; PROBABILITY; RESTENOSIS; SENSITIVITY AND SPECIFICITY;

EID: 33847282923     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2006.10.065     Document Type: Article
Times cited : (136)

References (33)
  • 1
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses J.W., Leon M.B., Popma J.J., et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349 (2003) 1315-1323
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 2
    • 25144508347 scopus 로고    scopus 로고
    • Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: a prospective, randomized trial
    • Pache J., Dibra A., Mehilli J., Dirschinger J., Schomig A., and Kastrati A. Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: a prospective, randomized trial. Eur Heart J 26 (2005) 1262-1268
    • (2005) Eur Heart J , vol.26 , pp. 1262-1268
    • Pache, J.1    Dibra, A.2    Mehilli, J.3    Dirschinger, J.4    Schomig, A.5    Kastrati, A.6
  • 3
    • 24044454767 scopus 로고    scopus 로고
    • Effectiveness of sirolimus-eluting stent implantation for the treatment of ostial left anterior descending artery stenosis with intravascular ultrasound guidance
    • Seung K.B., Kim Y.H., Park D.W., et al. Effectiveness of sirolimus-eluting stent implantation for the treatment of ostial left anterior descending artery stenosis with intravascular ultrasound guidance. J Am Coll Cardiol 46 (2005) 787-792
    • (2005) J Am Coll Cardiol , vol.46 , pp. 787-792
    • Seung, K.B.1    Kim, Y.H.2    Park, D.W.3
  • 4
    • 23844538250 scopus 로고    scopus 로고
    • Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients
    • Dibra A., Kastrati A., Mehilli J., et al. Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients. N Engl J Med 353 (2005) 663-670
    • (2005) N Engl J Med , vol.353 , pp. 663-670
    • Dibra, A.1    Kastrati, A.2    Mehilli, J.3
  • 5
    • 0037109216 scopus 로고    scopus 로고
    • Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    • Nieman K., Cademartiri F., Lemos P.A., Raaijmakers R., Pattynama P.M., and deFeyter P.J. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106 (2002) 2051-2054
    • (2002) Circulation , vol.106 , pp. 2051-2054
    • Nieman, K.1    Cademartiri, F.2    Lemos, P.A.3    Raaijmakers, R.4    Pattynama, P.M.5    deFeyter, P.J.6
  • 6
    • 0037432175 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    • Ropers D., Baum U., Pohle K., et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107 (2003) 664-666
    • (2003) Circulation , vol.107 , pp. 664-666
    • Ropers, D.1    Baum, U.2    Pohle, K.3
  • 7
    • 7544220286 scopus 로고    scopus 로고
    • Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis
    • Hoffmann U., Moselewski F., Cury R.C., et al. Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation 110 (2004) 2638-2643
    • (2004) Circulation , vol.110 , pp. 2638-2643
    • Hoffmann, U.1    Moselewski, F.2    Cury, R.C.3
  • 8
    • 10744227532 scopus 로고    scopus 로고
    • Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography
    • Achenbach S., Ropers D., Hoffmann U., et al. Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography. J Am Coll Cardiol 43 (2004) 842-847
    • (2004) J Am Coll Cardiol , vol.43 , pp. 842-847
    • Achenbach, S.1    Ropers, D.2    Hoffmann, U.3
  • 9
    • 11144247393 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution
    • Kuettner A., Beck T., Drosch T., et al. Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol 45 (2005) 123-127
    • (2005) J Am Coll Cardiol , vol.45 , pp. 123-127
    • Kuettner, A.1    Beck, T.2    Drosch, T.3
  • 10
    • 11144241927 scopus 로고    scopus 로고
    • Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography
    • Mollet N.R., Cademartiri F., Krestin G.P., et al. Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. J Am Coll Cardiol 45 (2005) 128-132
    • (2005) J Am Coll Cardiol , vol.45 , pp. 128-132
    • Mollet, N.R.1    Cademartiri, F.2    Krestin, G.P.3
  • 11
    • 25444519367 scopus 로고    scopus 로고
    • Accuracy of MSCT coronary angiography with 64-slice technology: first experience
    • Leschka S., Alkadhi H., Plass A., et al. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26 (2005) 1482-1487
    • (2005) Eur Heart J , vol.26 , pp. 1482-1487
    • Leschka, S.1    Alkadhi, H.2    Plass, A.3
  • 12
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography a comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber A.W., Knez A., vonZiegler F., et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46 (2005) 147-154
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    vonZiegler, F.3
  • 13
    • 4644360295 scopus 로고    scopus 로고
    • Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience
    • Hong C., Chrysant G.S., Woodard P.K., and Bae K.T. Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience. Radiology 233 (2004) 286-291
    • (2004) Radiology , vol.233 , pp. 286-291
    • Hong, C.1    Chrysant, G.S.2    Woodard, P.K.3    Bae, K.T.4
  • 14
    • 26844477979 scopus 로고    scopus 로고
    • Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography
    • Gaspar T., Halon D.A., Lewis B.S., et al. Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography. J Am Coll Cardiol 46 (2005) 1573-1579
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1573-1579
    • Gaspar, T.1    Halon, D.A.2    Lewis, B.S.3
  • 15
    • 29644441328 scopus 로고    scopus 로고
    • Assessment of coronary artery stents by 16 slice computed tomography
    • Gilard M., Cornily J.C., Pennec P.Y., et al. Assessment of coronary artery stents by 16 slice computed tomography. Heart 92 (2006) 58-61
    • (2006) Heart , vol.92 , pp. 58-61
    • Gilard, M.1    Cornily, J.C.2    Pennec, P.Y.3
  • 16
    • 33646102670 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography
    • Ehara M., Surmely J.F., Kawai M., et al. Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 70 (2006) 564-571
    • (2006) Circ J , vol.70 , pp. 564-571
    • Ehara, M.1    Surmely, J.F.2    Kawai, M.3
  • 17
    • 0033517846 scopus 로고    scopus 로고
    • Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome
    • Mehran R., Dangas G., Abizaid A.S., et al. Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. Circulation 100 (1999) 1872-1878
    • (1999) Circulation , vol.100 , pp. 1872-1878
    • Mehran, R.1    Dangas, G.2    Abizaid, A.S.3
  • 18
    • 9044235783 scopus 로고    scopus 로고
    • Accurate three-dimensional reconstruction of intravascular ultrasound data. Spatially correct three-dimensional reconstructions
    • Evans J.L., Ng K.H., Wiet S.G., et al. Accurate three-dimensional reconstruction of intravascular ultrasound data. Spatially correct three-dimensional reconstructions. Circulation 93 (1996) 567-576
    • (1996) Circulation , vol.93 , pp. 567-576
    • Evans, J.L.1    Ng, K.H.2    Wiet, S.G.3
  • 19
    • 0031043718 scopus 로고    scopus 로고
    • Impact of curve distortion errors on intravascular ultrasound measurements and three-dimensional reconstructions
    • Schwarzacher S.P., Honda Y., Metz J.A., Asvar C.A., Fitzgerald P.J., and Yock P.G. Impact of curve distortion errors on intravascular ultrasound measurements and three-dimensional reconstructions. Am J Cardiol 79 (1997) 384-387
    • (1997) Am J Cardiol , vol.79 , pp. 384-387
    • Schwarzacher, S.P.1    Honda, Y.2    Metz, J.A.3    Asvar, C.A.4    Fitzgerald, P.J.5    Yock, P.G.6
  • 20
    • 10344243994 scopus 로고    scopus 로고
    • Sirolimus-eluting vs uncoated stents for prevention of restenosis in small coronary arteries: a randomized trial
    • Ardissino D., Cavallini C., Bramucci E., et al. Sirolimus-eluting vs uncoated stents for prevention of restenosis in small coronary arteries: a randomized trial. JAMA 292 (2004) 2727-2734
    • (2004) JAMA , vol.292 , pp. 2727-2734
    • Ardissino, D.1    Cavallini, C.2    Bramucci, E.3
  • 21
    • 27644462729 scopus 로고    scopus 로고
    • Effect of sirolimus-eluting stent in diabetic patients with small coronary arteries (a SES-SMART substudy)
    • Ortolani P., Ardissino D., Cavallini C., et al. Effect of sirolimus-eluting stent in diabetic patients with small coronary arteries (a SES-SMART substudy). Am J Cardiol 96 (2005) 1393-1398
    • (2005) Am J Cardiol , vol.96 , pp. 1393-1398
    • Ortolani, P.1    Ardissino, D.2    Cavallini, C.3
  • 22
    • 0035863644 scopus 로고    scopus 로고
    • Final results of a randomized trial comparing the MULTI-LINK stent with the Palmaz-Schatz stent for narrowings in native coronary arteries
    • Baim D.S., Cutlip D.E., Midei M., et al. Final results of a randomized trial comparing the MULTI-LINK stent with the Palmaz-Schatz stent for narrowings in native coronary arteries. Am J Cardiol 87 (2001) 157-162
    • (2001) Am J Cardiol , vol.87 , pp. 157-162
    • Baim, D.S.1    Cutlip, D.E.2    Midei, M.3
  • 23
    • 17944369465 scopus 로고    scopus 로고
    • The influence of stent length on clinical and angiographic outcome in patients undergoing elective stenting for native coronary artery lesions; final results of the Magic 5L Study
    • Foley D.P., Pieper M., Wijns W., et al. The influence of stent length on clinical and angiographic outcome in patients undergoing elective stenting for native coronary artery lesions; final results of the Magic 5L Study. Eur Heart J 22 (2001) 1585-1593
    • (2001) Eur Heart J , vol.22 , pp. 1585-1593
    • Foley, D.P.1    Pieper, M.2    Wijns, W.3
  • 24
    • 0035849543 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial
    • Kastrati A., Mehilli J., Dirschinger J., et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 103 (2001) 2816-2821
    • (2001) Circulation , vol.103 , pp. 2816-2821
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 25
    • 33744469345 scopus 로고    scopus 로고
    • Images in cardiology. Stent structure after kissing balloon inflation visualised by 64 slice computed tomography
    • Ehara M., Kawai M., and Suzuki T. Images in cardiology. Stent structure after kissing balloon inflation visualised by 64 slice computed tomography. Heart 92 (2006) 837
    • (2006) Heart , vol.92 , pp. 837
    • Ehara, M.1    Kawai, M.2    Suzuki, T.3
  • 26
    • 10344230948 scopus 로고    scopus 로고
    • Performance evaluation of a 64-slice CT system with z-flying focal spot
    • Flohr T., Stierstorfer K., Raupach R., Ulzheimer S., and Bruder H. Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo 176 (2004) 1803-1810
    • (2004) Rofo , vol.176 , pp. 1803-1810
    • Flohr, T.1    Stierstorfer, K.2    Raupach, R.3    Ulzheimer, S.4    Bruder, H.5
  • 27
    • 33645064323 scopus 로고    scopus 로고
    • 64- versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience
    • Seifarth H., Ozgun M., Raupach R., et al. 64- versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience. Invest Radiol 41 (2006) 22-27
    • (2006) Invest Radiol , vol.41 , pp. 22-27
    • Seifarth, H.1    Ozgun, M.2    Raupach, R.3
  • 28
    • 4344714403 scopus 로고    scopus 로고
    • Feasibility of assessment of coronary stent patency using 16-slice computed tomography
    • Schuijf J.D., Bax J.J., Jukema J.W., et al. Feasibility of assessment of coronary stent patency using 16-slice computed tomography. Am J Cardiol 94 (2004) 427-430
    • (2004) Am J Cardiol , vol.94 , pp. 427-430
    • Schuijf, J.D.1    Bax, J.J.2    Jukema, J.W.3
  • 29
    • 21344470576 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. In-stent neointimal hyperplasia with 16-row multislice computed tomography coronary angiography
    • Mollet N.R., and Cademartiri F. Images in cardiovascular medicine. In-stent neointimal hyperplasia with 16-row multislice computed tomography coronary angiography. Circulation 110 (2004) e514
    • (2004) Circulation , vol.110
    • Mollet, N.R.1    Cademartiri, F.2
  • 30
    • 24944437152 scopus 로고    scopus 로고
    • Usefulness of multislice computed tomographic coronary angiography to assess in-stent restenosis
    • Cademartiri F., Mollet N., Lemos P.A., et al. Usefulness of multislice computed tomographic coronary angiography to assess in-stent restenosis. Am J Cardiol 96 (2005) 799-802
    • (2005) Am J Cardiol , vol.96 , pp. 799-802
    • Cademartiri, F.1    Mollet, N.2    Lemos, P.A.3
  • 31
    • 15944425066 scopus 로고    scopus 로고
    • Patency of the right coronary artery following implantation of metallic stent demonstrated by multislice computed tomography
    • Funabashi N., Komiyama N., and Komuro I. Patency of the right coronary artery following implantation of metallic stent demonstrated by multislice computed tomography. Heart 91 (2005) 436
    • (2005) Heart , vol.91 , pp. 436
    • Funabashi, N.1    Komiyama, N.2    Komuro, I.3
  • 32
    • 18044380894 scopus 로고    scopus 로고
    • Multislice CT to evaluate coronary stent patency: a case report
    • Soon K.H., Bell K.W., and Lim Y.L. Multislice CT to evaluate coronary stent patency: a case report. Catheter Cardiovasc Interv 65 (2005) 34-36
    • (2005) Catheter Cardiovasc Interv , vol.65 , pp. 34-36
    • Soon, K.H.1    Bell, K.W.2    Lim, Y.L.3
  • 33
    • 33645857186 scopus 로고    scopus 로고
    • 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents
    • Maintz D., Seifarth H., Raupach R., et al. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol (2005) 1-9
    • (2005) Eur Radiol , pp. 1-9
    • Maintz, D.1    Seifarth, H.2    Raupach, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.