메뉴 건너뛰기




Volumn 60, Issue 5, 2008, Pages 1250-1255

Linear phase-error correction for improved water and fat separation in dual-echo dixon techniques

Author keywords

Dixon water fat separation; Dual echo acquisition; Linear phase errors; Phase correction; Region growing

Indexed keywords

EDDY CURRENTS; ERROR CORRECTION;

EID: 55749102851     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21747     Document Type: Article
Times cited : (18)

References (25)
  • 1
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT. Simple proton spectroscopic imaging. Radiology 1984;153:189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 3
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • Glover GH. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991;1:521-530.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 521-530
    • Glover, G.H.1
  • 4
    • 0030229102 scopus 로고    scopus 로고
    • Inversion recovery image reconstruction with multiseed region-growing spin reversal
    • Xiang QS. Inversion recovery image reconstruction with multiseed region-growing spin reversal. J Magn Reson Imaging 1996;6:775-782.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 775-782
    • Xiang, Q.S.1
  • 5
    • 16444378797 scopus 로고    scopus 로고
    • Multislice and multicoil phase-sensitive inversion-recovery imaging
    • Ma J. Multislice and multicoil phase-sensitive inversion-recovery imaging. Magn Reson Med 2005;53:904-910.
    • (2005) Magn Reson Med , vol.53 , pp. 904-910
    • Ma, J.1
  • 6
    • 3543083453 scopus 로고    scopus 로고
    • Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm
    • Ma J. Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm. Magn Reson Med 2004;52:415-419.
    • (2004) Magn Reson Med , vol.52 , pp. 415-419
    • Ma, J.1
  • 7
    • 30744448686 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI
    • Ma J, Vu AT, Son JB, Choi H, Hazle JD. Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI. J Magn Reson Imaging 2006;23:36-41.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 36-41
    • Ma, J.1    Vu, A.T.2    Son, J.B.3    Choi, H.4    Hazle, J.D.5
  • 9
    • 0031401552 scopus 로고    scopus 로고
    • Water-fat imaging with direct phase encoding
    • Xiang QS, An L. Water-fat imaging with direct phase encoding. J Magn Reson Imaging 1997;7:1002-1015.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 1002-1015
    • Xiang, Q.S.1    An, L.2
  • 10
    • 0028068852 scopus 로고
    • Phase unwrapping in the three-point Dixon method for fat suppression MR imaging
    • Szumowski J, Coshow WR, Li F, Quinn SF. Phase unwrapping in the three-point Dixon method for fat suppression MR imaging. Radiology 1994;192:555-561.
    • (1994) Radiology , vol.192 , pp. 555-561
    • Szumowski, J.1    Coshow, W.R.2    Li, F.3    Quinn, S.F.4
  • 11
    • 26844562367 scopus 로고    scopus 로고
    • Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition
    • Yu H, Reeder SB, Shimakawa A, Brittain JH, Pelc NJ. Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition. Magn Reson Med 2005;54:1032-1039.
    • (2005) Magn Reson Med , vol.54 , pp. 1032-1039
    • Yu, H.1    Reeder, S.B.2    Shimakawa, A.3    Brittain, J.H.4    Pelc, N.J.5
  • 12
    • 35448989836 scopus 로고    scopus 로고
    • Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients
    • Yeo DTB, Chenevert TL, Fessler JA, Kim B. Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients. Magn Reson Imaging 2007;25:1263-1271.
    • (2007) Magn Reson Imaging , vol.25 , pp. 1263-1271
    • Yeo, D.T.B.1    Chenevert, T.L.2    Fessler, J.A.3    Kim, B.4
  • 13
    • 0023306810 scopus 로고
    • A new phase correction method in NMR imaging based on autocorrelation and histogram analysis
    • Ahn CB, Cho ZH. A new phase correction method in NMR imaging based on autocorrelation and histogram analysis. IEEE Trans Med Imaging 1986;6:32-36.
    • (1986) IEEE Trans Med Imaging , vol.6 , pp. 32-36
    • Ahn, C.B.1    Cho, Z.H.2
  • 14
    • 51449104486 scopus 로고    scopus 로고
    • LAVA dual echo with water reconstruction: Preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging
    • Berlin, Germany, Abstract 726
    • Low RN, Knowles A, Vu AT, Slavens Z, Estowski L. LAVA dual echo with water reconstruction: preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging. In: Proceedings of the 15th Annual Scientific Meeting of ISMRM, Berlin, Germany, 2007 (Abstract 726).
    • (2007) Proceedings of the 15th Annual Scientific Meeting of ISMRM
    • Low, R.N.1    Knowles, A.2    Vu, A.T.3    Slavens, Z.4    Estowski, L.5
  • 15
    • 9644291523 scopus 로고    scopus 로고
    • T2-weighted spine imaging with a fast three-point Dixon technique: Comparison with chemical shift selective fat suppression
    • Ma J, Singh SK, Kumar AJ, Leeds NE, Zhan J. T2-weighted spine imaging with a fast three-point Dixon technique: comparison with chemical shift selective fat suppression. J Magn Reson Imaging 2004;20:1025-1029.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 1025-1029
    • Ma, J.1    Singh, S.K.2    Kumar, A.J.3    Leeds, N.E.4    Zhan, J.5
  • 16
    • 29244446245 scopus 로고    scopus 로고
    • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging
    • Ma J, Son JB, Bankson JA, Stafford RJ, Choi H, Ragan D. A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging. Magn Reson Imaging 2005;23:977-982.
    • (2005) Magn Reson Imaging , vol.23 , pp. 977-982
    • Ma, J.1    Son, J.B.2    Bankson, J.A.3    Stafford, R.J.4    Choi, H.5    Ragan, D.6
  • 19
    • 0034238079 scopus 로고    scopus 로고
    • A fast implementation of the minimum spanning tree method for phase unwrapping
    • An L, Xiang QS, Chavez S. A fast implementation of the minimum spanning tree method for phase unwrapping. IEEE Trans Med Imaging 2000;19:805-808.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 805-808
    • An, L.1    Xiang, Q.S.2    Chavez, S.3
  • 20
    • 34250336900 scopus 로고    scopus 로고
    • Fast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm
    • Li Z, Gmitro AF, Bilgin A, Altbach MI. Fast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm. Magn Reson Med 2007;57:1047-1057.
    • (2007) Magn Reson Med , vol.57 , pp. 1047-1057
    • Li, Z.1    Gmitro, A.F.2    Bilgin, A.3    Altbach, M.I.4
  • 21
    • 0030419995 scopus 로고    scopus 로고
    • A model-based method for phase unwrapping
    • Liang ZP. A model-based method for phase unwrapping. IEEE Trans Med Imaging 1996;15:893-897.
    • (1996) IEEE Trans Med Imaging , vol.15 , pp. 893-897
    • Liang, Z.P.1
  • 22
    • 0034752903 scopus 로고    scopus 로고
    • k-Space weighted leastsquares algorithm for accurate and fast motion extraction from magnetic resonance navigator echoes
    • Nguyen TD, Wang Y, Watts R, Mitchell I. k-Space weighted leastsquares algorithm for accurate and fast motion extraction from magnetic resonance navigator echoes. Magn Reson Med 2001;46:1037-1040.
    • (2001) Magn Reson Med , vol.46 , pp. 1037-1040
    • Nguyen, T.D.1    Wang, Y.2    Watts, R.3    Mitchell, I.4
  • 23
    • 0032858862 scopus 로고    scopus 로고
    • A computationally efficient method for tracking reference position displacements for motion compensation in magnetic resonance imaging
    • Foo TK, King KF. A computationally efficient method for tracking reference position displacements for motion compensation in magnetic resonance imaging. Magn Reson Med 1999;42:548-553.
    • (1999) Magn Reson Med , vol.42 , pp. 548-553
    • Foo, T.K.1    King, K.F.2
  • 24
    • 0037925300 scopus 로고    scopus 로고
    • Centering the projection reconstruction trajectory: Reducing gradient delay errors
    • Peters DC, Derbyshire JA, McVeigh ER. Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 2003;50:1-6.
    • (2003) Magn Reson Med , vol.50 , pp. 1-6
    • Peters, D.C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 25
    • 34547736137 scopus 로고    scopus 로고
    • Fast spin-echo triple-echo Dixon (fTED) technique for efficient T2-weighted water and fat imaging
    • Ma J, Son JB, Zhou Y, Le-Petross H, Choi H. Fast spin-echo triple-echo Dixon (fTED) technique for efficient T2-weighted water and fat imaging. Magn Reson Med 2007;58:103-109.
    • (2007) Magn Reson Med , vol.58 , pp. 103-109
    • Ma, J.1    Son, J.B.2    Zhou, Y.3    Le-Petross, H.4    Choi, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.