메뉴 건너뛰기




Volumn , Issue , 2009, Pages 349-353

Controlling a powered exoskeleton system via electromyographic signals

Author keywords

[No Author keywords available]

Indexed keywords

ASSISTIVE TECHNOLOGY; ELECTROMYOGRAPHIC SIGNAL; EMG CONTROL; EXOSKELETON SYSTEMS; HUMAN MACHINE INTERFACE; HUMAN-MACHINE SYSTEMS; LIGHT-WEIGHT ROBOTICS; MUSCLE STRENGTH;

EID: 77951464008     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBIO.2009.5420670     Document Type: Conference Paper
Times cited : (6)

References (23)
  • 1
    • 33745159001 scopus 로고    scopus 로고
    • Torque control of an exoskeleton knee with EMG signals
    • C. Fleischer and G. Hommel, "Torque control of an exoskeleton knee with EMG signals," VDI BERICHTE, 2006.
    • (2006) VDI BERICHTE
    • Fleischer, C.1    Hommel, G.2
  • 2
    • 0002352147 scopus 로고
    • Force reflecting electrohydraulic servo manipulator
    • Dec.
    • R. S. Mosher, "Force reflecting electrohydraulic servo manipulator," Electro-Tech., Dec. 1960.
    • (1960) Electro-Tech.
    • Mosher, R.S.1
  • 5
    • 0004674281 scopus 로고
    • Research and development prototype for machine augmentation of human strength and endurance, Hardiman I project
    • B. J. Makinson, "Research and development prototype for machine augmentation of human strength and endurance, Hardiman I project," General Electric Co., Schenectady, NY, Rep. S-71-106, 1971.
    • (1971) General Electric Co., Schenectady, NY, Rep. S-71-106
    • Makinson, B.J.1
  • 7
    • 33646347917 scopus 로고    scopus 로고
    • The Berkeley lower extremity exoskeleton
    • H. Kazerooni and R. Steger, "The Berkeley lower extremity exoskeleton," J Dyn Syst Measur Control, vol. 128, pp. 14-25, 2006.
    • (2006) J Dyn Syst Measur Control , vol.128 , pp. 14-25
    • Kazerooni, H.1    Steger, R.2
  • 10
    • 0042664129 scopus 로고    scopus 로고
    • A robust, real-time control scheme for multifunction myoelectric control
    • K. Englehart and B. Hudgins, "A robust, real-time control scheme for multifunction myoelectric control," IEEE Trans. Biomed. Eng., vol. 50, pp. 848-854, 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , pp. 848-854
    • Englehart, K.1    Hudgins, B.2
  • 11
    • 0030176292 scopus 로고    scopus 로고
    • A randomization method for discriminating between signal and noise in recordings of rhythmic electromyographic activity
    • A. J. Thexton, "A randomization method for discriminating between signal and noise in recordings of rhythmic electromyographic activity," J Neurosci Meth, vol. 66, pp. 93-98, 1996.
    • (1996) J Neurosci Meth , vol.66 , pp. 93-98
    • Thexton, A.J.1
  • 12
    • 33645224070 scopus 로고    scopus 로고
    • Techniques of EMG signal analysis: Detection, processing, classification and applications
    • Available
    • M. B. I. Reaz, M. S. Hussain, and F. Mohd-Yasin, "Techniques of EMG signal analysis: detection, processing, classification and applications," Biol. Proceed. Online, vol. 8, pp. 11-35, 2006. Available: http://www. biologicalprocedures.com
    • (2006) Biol. Proceed. Online , vol.8 , pp. 11-35
    • Reaz, M.B.I.1    Hussain, M.S.2    Mohd-Yasin, F.3
  • 13
    • 0032032877 scopus 로고    scopus 로고
    • A statistical method for the measurement of the muscle activation intervals from surface myoelectric signal gait
    • P. Bornato, T. de Alessio and M. Knaflitz, "A statistical method for the measurement of the muscle activation intervals from surface myoelectric signal gait," IEEE Trans Biomed Eng, vol. 45, pp. 287-299, 1998.
    • (1998) IEEE Trans Biomed Eng , vol.45 , pp. 287-299
    • Bornato, P.1    De Alessio, T.2    Knaflitz, M.3
  • 15
    • 0037339348 scopus 로고    scopus 로고
    • A fast and reliable technique for muscle activity detection from surface EMG signals
    • DOI 10.1109/TBME.2003.808829
    • A. Merlo and D. Farina, "A fast and reliable technique for muscle activity detection from surface EMG signals," IEEE Trans Biomed Eng, vol.50, pp. 316-323, 2003. (Pubitemid 36331673)
    • (2003) IEEE Transactions on Biomedical Engineering , vol.50 , Issue.3 , pp. 316-323
    • Merlo, A.1    Farina, D.2    Merletti, R.3
  • 16
    • 0041928181 scopus 로고    scopus 로고
    • The development of a virtual myoelectric prosthesis controlled by an EMG pattern recognition system based on neural networks
    • A. Soares, A. Andrade, E. Lamounier and R. Carrijo, "The development of a virtual myoelectric prosthesis controlled by an EMG pattern recognition system based on neural networks," J. Intelligent Information Systems, vol. 21, pp. 127-141, 2003.
    • (2003) J. Intelligent Information Systems , vol.21 , pp. 127-141
    • Soares, A.1    Andrade, A.2    Lamounier, E.3    Carrijo, R.4
  • 17
    • 77951475655 scopus 로고    scopus 로고
    • Chinese source
  • 18
    • 0033822989 scopus 로고    scopus 로고
    • Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
    • D. Farina and R. Merletti, "Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions," J. Electromyogr. Kinesiol, vol. 10, pp. 337-349, 2000.
    • (2000) J. Electromyogr. Kinesiol , vol.10 , pp. 337-349
    • Farina, D.1    Merletti, R.2
  • 22
    • 0038368884 scopus 로고    scopus 로고
    • An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo
    • D. G. Lloyd and T. F. Besier, "An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo," J. Biomechanics 36, pp. 765-776, 2003.
    • (2003) J. Biomechanics , vol.36 , pp. 765-776
    • Lloyd, D.G.1    Besier, T.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.