메뉴 건너뛰기




Volumn 10, Issue 4, 2010, Pages 1227-1230

Gold nanoparticle-based signal augmentation of quartz crystal microbalance immunosensor measuring C-reactive protein

Author keywords

C reactive protein; Gold nanoparticle; Quartz crystal microbalance immunosensor; Signal augmentation

Indexed keywords

C-REACTIVE PROTEINS; CONCENTRATION OF; FREQUENCY SHIFT; GOLD NANOPARTICLE; GOLD NANOPARTICLES; HEXANOATE; SENSITIVITY IMPROVEMENTS; SENSOR CHIPS; STREPTAVIDIN;

EID: 77951217259     PISSN: 15671739     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cap.2010.02.048     Document Type: Article
Times cited : (39)

References (35)
  • 1
    • 71849110876 scopus 로고    scopus 로고
    • Development of indirect-competitive quartz crystal microbalance immunosensor for C-reactive protein
    • Kim N., Kim D.K., and Cho Y.J. Development of indirect-competitive quartz crystal microbalance immunosensor for C-reactive protein. Sens. Actuators B: Chem. 143 (2009) 444-448
    • (2009) Sens. Actuators B: Chem. , vol.143 , pp. 444-448
    • Kim, N.1    Kim, D.K.2    Cho, Y.J.3
  • 2
    • 33646547256 scopus 로고    scopus 로고
    • Modulatory activity of Bifidobacterium sp. BGN4 cell fractions on immune cells
    • Kim N., and Ji G.E. Modulatory activity of Bifidobacterium sp. BGN4 cell fractions on immune cells. J. Microbiol. Biotechnol. 16 (2006) 584-589
    • (2006) J. Microbiol. Biotechnol. , vol.16 , pp. 584-589
    • Kim, N.1    Ji, G.E.2
  • 3
    • 38949209855 scopus 로고    scopus 로고
    • Moderate exercise training does not worsen left ventricle remodeling and function in untreated severe hypertensive rats
    • Boissiere J., Eder V., Machet M.C., Courteix D., and Bonnet P. Moderate exercise training does not worsen left ventricle remodeling and function in untreated severe hypertensive rats. J. Appl. Physiol. 104 (2008) 321-327
    • (2008) J. Appl. Physiol. , vol.104 , pp. 321-327
    • Boissiere, J.1    Eder, V.2    Machet, M.C.3    Courteix, D.4    Bonnet, P.5
  • 5
    • 4644332790 scopus 로고    scopus 로고
    • Measurement of C-reactive protein: two high sensitivity methods compared
    • Dominichi R., Luraschi P., and Franzini C. Measurement of C-reactive protein: two high sensitivity methods compared. J. Clin. Lab. Anal. 18 (2004) 280-284
    • (2004) J. Clin. Lab. Anal. , vol.18 , pp. 280-284
    • Dominichi, R.1    Luraschi, P.2    Franzini, C.3
  • 6
    • 13444282300 scopus 로고    scopus 로고
    • Use of a time-resolved immunofluorometric assay for determination of canine C-reactive protein concentrations in whole blood
    • Parra M.D., Tuomola M., Cabezas-Herrera J., and Ceron J.J. Use of a time-resolved immunofluorometric assay for determination of canine C-reactive protein concentrations in whole blood. Am. J. Veter. Res. 1 (2005) 62-66
    • (2005) Am. J. Veter. Res. , vol.1 , pp. 62-66
    • Parra, M.D.1    Tuomola, M.2    Cabezas-Herrera, J.3    Ceron, J.J.4
  • 7
    • 0034351355 scopus 로고    scopus 로고
    • Evaluation of antibody immobilization methods for piezoelectric biosensor application
    • Babacan S., Pivarnik P., Letcher S., and Rand A.G. Evaluation of antibody immobilization methods for piezoelectric biosensor application. Biosens. Bioelectron. 15 (2000) 615-621
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 615-621
    • Babacan, S.1    Pivarnik, P.2    Letcher, S.3    Rand, A.G.4
  • 8
    • 35348875520 scopus 로고    scopus 로고
    • Flatfish vitellogenin detection using optical waveguide light mode spectroscopy-based immunosensor
    • Kim N., Ryu H.-S., and Kim W.-Y. Flatfish vitellogenin detection using optical waveguide light mode spectroscopy-based immunosensor. J. Microbiol. Biotechnol. 17 (2007) 1445-1451
    • (2007) J. Microbiol. Biotechnol. , vol.17 , pp. 1445-1451
    • Kim, N.1    Ryu, H.-S.2    Kim, W.-Y.3
  • 9
    • 0033545342 scopus 로고    scopus 로고
    • Acute-phase proteins and other systemic responses to inflammation
    • Gabay C., and Kushner I.N. Acute-phase proteins and other systemic responses to inflammation. New Eng. J. Med. 340 (1999) 448-454
    • (1999) New Eng. J. Med. , vol.340 , pp. 448-454
    • Gabay, C.1    Kushner, I.N.2
  • 10
    • 0035103498 scopus 로고    scopus 로고
    • High-sensitivity C-reactive protein: a novel and promising marker of coronary heart disease
    • Rifai N., and Ridker P.M. High-sensitivity C-reactive protein: a novel and promising marker of coronary heart disease. Clin. Chem. 47 (2001) 403-411
    • (2001) Clin. Chem. , vol.47 , pp. 403-411
    • Rifai, N.1    Ridker, P.M.2
  • 11
    • 1642287457 scopus 로고    scopus 로고
    • Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks
    • Wolf M., Juncker D., Michel B., Hunziker P., and Emmanuel D. Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks. Biosens. Bioelectron. 19 (2004) 1193-1202
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1193-1202
    • Wolf, M.1    Juncker, D.2    Michel, B.3    Hunziker, P.4    Emmanuel, D.5
  • 13
    • 8844221262 scopus 로고    scopus 로고
    • Evaluation of a high-affinity QCM immunosensor using antibody fragmentation and 2-methacryloylethyl phosphorylcholine (MPC) polymer
    • Kurosawa S., Nakamura M., Park J.W., Aizawa H., Yamada K., and Hirata M. Evaluation of a high-affinity QCM immunosensor using antibody fragmentation and 2-methacryloylethyl phosphorylcholine (MPC) polymer. Biosens. Bioelectron. 20 (2004) 1134-1139
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 1134-1139
    • Kurosawa, S.1    Nakamura, M.2    Park, J.W.3    Aizawa, H.4    Yamada, K.5    Hirata, M.6
  • 14
    • 33847036986 scopus 로고    scopus 로고
    • Antibody immobilization to phospholipid polymer layer on gold substrate of quartz crystal microbalance immunosensor
    • Park J., Kurosawa S., Takai M., and Ishihara K. Antibody immobilization to phospholipid polymer layer on gold substrate of quartz crystal microbalance immunosensor. Colloids Surf. B: Biointerf. 55 (2007) 164-172
    • (2007) Colloids Surf. B: Biointerf. , vol.55 , pp. 164-172
    • Park, J.1    Kurosawa, S.2    Takai, M.3    Ishihara, K.4
  • 15
    • 33846646497 scopus 로고    scopus 로고
    • Salmonella detection with a direct-binding optical grating coupler immunosensor
    • Kim N., Park I.S., and Kim W.Y. Salmonella detection with a direct-binding optical grating coupler immunosensor. Sens. Actuators B: Chem. 121 (2007) 606-615
    • (2007) Sens. Actuators B: Chem. , vol.121 , pp. 606-615
    • Kim, N.1    Park, I.S.2    Kim, W.Y.3
  • 16
    • 11144237198 scopus 로고    scopus 로고
    • Development of fluorescent change-based reagent-less optic immunosensor
    • Aoyagi S., and Kudo M. Development of fluorescent change-based reagent-less optic immunosensor. Biosens. Bioelectron. 20 (2005) 1680-1684
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 1680-1684
    • Aoyagi, S.1    Kudo, M.2
  • 17
    • 33646414203 scopus 로고    scopus 로고
    • Surface modification of silica nanoparticles to reduce aggregation and nonspecific binding
    • Bagwe R.P., Hilliard L.R., and Tan W. Surface modification of silica nanoparticles to reduce aggregation and nonspecific binding. Langmuir 22 (2006) 4357-4362
    • (2006) Langmuir , vol.22 , pp. 4357-4362
    • Bagwe, R.P.1    Hilliard, L.R.2    Tan, W.3
  • 20
    • 36549004111 scopus 로고    scopus 로고
    • Versatile immunosensor using CdTe quantum dots as electrochemical and fluorescent labels
    • Cui R., Pan H.C., Zhu J.J., and Chen H.Y. Versatile immunosensor using CdTe quantum dots as electrochemical and fluorescent labels. Anal. Chem. 79 (2007) 8494-8501
    • (2007) Anal. Chem. , vol.79 , pp. 8494-8501
    • Cui, R.1    Pan, H.C.2    Zhu, J.J.3    Chen, H.Y.4
  • 21
    • 43449086103 scopus 로고    scopus 로고
    • Electrochemiluminescence of CdSe quantum dots for immunosensing of human prealbumin
    • Jie G., Huang H., Sun X., and Zhu J.J. Electrochemiluminescence of CdSe quantum dots for immunosensing of human prealbumin. Biosens. Bioelectron. 23 (2008) 1896-1899
    • (2008) Biosens. Bioelectron. , vol.23 , pp. 1896-1899
    • Jie, G.1    Huang, H.2    Sun, X.3    Zhu, J.J.4
  • 22
    • 34548577046 scopus 로고    scopus 로고
    • Synthesis characterization and biological applications of multifluorescent silica nanoparticles
    • Nakamura M., Shono M., and Ishimura K. Synthesis characterization and biological applications of multifluorescent silica nanoparticles. Anal. Chem. 79 (2007) 6507-6514
    • (2007) Anal. Chem. , vol.79 , pp. 6507-6514
    • Nakamura, M.1    Shono, M.2    Ishimura, K.3
  • 23
    • 33750018114 scopus 로고    scopus 로고
    • Amplification of the antigen-antibody interaction from quartz crystal microbalance immunosensors via back-filling immobilization of nanogold on biorecognition surface
    • Tang D.Q., Zhang D.J., Tang D.Y., and Ai H. Amplification of the antigen-antibody interaction from quartz crystal microbalance immunosensors via back-filling immobilization of nanogold on biorecognition surface. J. Immunol. Methods 316 (2006) 144-152
    • (2006) J. Immunol. Methods , vol.316 , pp. 144-152
    • Tang, D.Q.1    Zhang, D.J.2    Tang, D.Y.3    Ai, H.4
  • 24
    • 84951279351 scopus 로고
    • Verwendung von schwingquarzen zur wägung dünner schichten undzur mikrowägung
    • Sauerbrey G. Verwendung von schwingquarzen zur wägung dünner schichten undzur mikrowägung. Zeitschrift für Physik 155 (1959) 206-222
    • (1959) Zeitschrift für Physik , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 25
    • 18144421518 scopus 로고    scopus 로고
    • Nanoparticle labels in immunosensing using optical detection method
    • Seydack M. Nanoparticle labels in immunosensing using optical detection method. Biosens. Bioelectron. 20 (2005) 2454-2469
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 2454-2469
    • Seydack, M.1
  • 26
    • 0036010263 scopus 로고    scopus 로고
    • Detection of Escherichia coli O157:H7 in 10- and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides
    • DeMarco D., and Lim D.V. Detection of Escherichia coli O157:H7 in 10- and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides. J. Food Protect. 65 (2002) 596-602
    • (2002) J. Food Protect. , vol.65 , pp. 596-602
    • DeMarco, D.1    Lim, D.V.2
  • 28
    • 0029967368 scopus 로고    scopus 로고
    • Immobilization of antibodies as a versatile tool in hybridized capillary electrophoresis
    • Ensing K., and Paulus A. Immobilization of antibodies as a versatile tool in hybridized capillary electrophoresis. J. Pharm. Biomed. Anal. 14 (1996) 305-315
    • (1996) J. Pharm. Biomed. Anal. , vol.14 , pp. 305-315
    • Ensing, K.1    Paulus, A.2
  • 29
    • 20444421534 scopus 로고    scopus 로고
    • 4-(Dimethylamino)butyric acid labeling for electrochemiluminescence detection of biological substances by increasing sensitivity with gold nanoparticle amplification
    • Yin X.B., Qi B., Sun X., Yang X., and Wang E. 4-(Dimethylamino)butyric acid labeling for electrochemiluminescence detection of biological substances by increasing sensitivity with gold nanoparticle amplification. Anal. Chem. 77 (2005) 3525-3530
    • (2005) Anal. Chem. , vol.77 , pp. 3525-3530
    • Yin, X.B.1    Qi, B.2    Sun, X.3    Yang, X.4    Wang, E.5
  • 30
    • 0036883709 scopus 로고    scopus 로고
    • Highly sensitive detection of cocaine using a piezoelectric immunosensor
    • Halámek J., Makower A., Skládal P., and Scheller F.W. Highly sensitive detection of cocaine using a piezoelectric immunosensor. Biosens. Bioelectron. 17 (2002) 1045-1050
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 1045-1050
    • Halámek, J.1    Makower, A.2    Skládal, P.3    Scheller, F.W.4
  • 31
    • 33645222733 scopus 로고    scopus 로고
    • SPR-based immunosensor for the CRP detection - A new method to detect a well known protein
    • Meyer M.H.F., Hartmann M., and Keusgen M. SPR-based immunosensor for the CRP detection - A new method to detect a well known protein. Biosens. Bioelectron. 21 (2006) 1987-1990
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1987-1990
    • Meyer, M.H.F.1    Hartmann, M.2    Keusgen, M.3
  • 33
    • 29144455409 scopus 로고    scopus 로고
    • Site-directed immobilization of antibody fragments for detection of C-reactive protein
    • Vikholm-Lundin I., and Albers W.M. Site-directed immobilization of antibody fragments for detection of C-reactive protein. Biosens. Bioelectron. 21 (2006) 1141-1148
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1141-1148
    • Vikholm-Lundin, I.1    Albers, W.M.2
  • 34
    • 2142770220 scopus 로고    scopus 로고
    • Fluorescent nanoparticles as labels for immunometric assay of C-reactive protein using two-photon excitation assay technology
    • Koskinen J.O., Vaarno J., Meltola N.J., Soini J.T., Hänninen P.E., Luotola J., Waris M.E., and Soini A.E. Fluorescent nanoparticles as labels for immunometric assay of C-reactive protein using two-photon excitation assay technology. Anal. Biochem. 328 (2004) 210-218
    • (2004) Anal. Biochem. , vol.328 , pp. 210-218
    • Koskinen, J.O.1    Vaarno, J.2    Meltola, N.J.3    Soini, J.T.4    Hänninen, P.E.5    Luotola, J.6    Waris, M.E.7    Soini, A.E.8
  • 35
    • 0242418180 scopus 로고    scopus 로고
    • Application of atomic force microscopy and grating coupler for the characterization of biosensor surfaces
    • Kuhlmeier D., Rodda E., Kolarik L.O., Furlong D.N., and Bilitewski R. Application of atomic force microscopy and grating coupler for the characterization of biosensor surfaces. Biosens. Bioelectron. 18 (2003) 925-936
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 925-936
    • Kuhlmeier, D.1    Rodda, E.2    Kolarik, L.O.3    Furlong, D.N.4    Bilitewski, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.