메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2710-2714

A multimodal approach to image-derived input functions for brain PET

Author keywords

[No Author keywords available]

Indexed keywords

AREA UNDER THE CURVES; ARTERIAL BLOOD SAMPLING; B SPLINE CURVE; BLOOD SAMPLING; CAROTID ARTERY; CENTERLINES; HIGH RESOLUTION; HUMAN SUBJECTS; IMAGE-DERIVED INPUT FUNCTIONS; LEVEL SETS METHODS; MR IMAGES; MULTI-MODAL APPROACH; MULTI-MODALITY; PARTIAL VOLUME CORRECTION; PET DATA; PET IMAGES; SEGMENTED DATA; SEGMENTED REGIONS; SINGLE POLYNOMIALS;

EID: 77951201267     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5401977     Document Type: Conference Paper
Times cited : (14)

References (12)
  • 2
    • 36348961339 scopus 로고    scopus 로고
    • Characterization of the image-derived carotid artery input function using independent component analysis for the quantitation of [18F] fluorodeoxyglucose positron emission tomography images
    • K. Chen, X. Chen, R. Renaut, G. E. Alexander, D. Bandy, H. Guo, and E.M. Reiman, "Characterization of the image-derived carotid artery input function using independent component analysis for the quantitation of [18F] fluorodeoxyglucose positron emission tomography images," Phys. Med. Biol., vol. 52, pp. 7055-7071, 2007.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 7055-7071
    • Chen, K.1    Chen, X.2    Renaut, R.3    Alexander, G.E.4    Bandy, D.5    Guo, H.6    Reiman, E.M.7
  • 4
    • 0242653791 scopus 로고    scopus 로고
    • Evaluation of a new norepinephrine transporter PET ligand in baboons, both in brain and peripheral organs
    • Dec.
    • Y. S. Ding, K. S. Lin, V. Garza, P. Carter, D. Alexoff, J. Logan, C. Shea, Y. W. Xu, and P. King, "Evaluation of a new norepinephrine transporter PET ligand in baboons, both in brain and peripheral organs," Synapse, vol. 50, pp. 345-352, Dec. 2003.
    • (2003) Synapse , vol.50 , pp. 345-352
    • Ding, Y.S.1    Lin, K.S.2    Garza, V.3    Carter, P.4    Alexoff, D.5    Logan, J.6    Shea, C.7    Xu, Y.W.8    King, P.9
  • 6
    • 0035140276 scopus 로고    scopus 로고
    • Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET
    • R. Boellaard, A. van Lingen, S. C. M. van Balen, B. G. Hoving, and A. A. Lammertsma. "Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET," Eur. J. Nuc. Med., vol. 28, pp. 81-89, 2001.
    • (2001) Eur. J. Nuc. Med. , vol.28 , pp. 81-89
    • Boellaard, R.1    Van Lingen, A.2    Van Balen, S.C.M.3    Hoving, B.G.4    Lammertsma, A.A.5
  • 8
    • 0035248865 scopus 로고    scopus 로고
    • Active contours without edges
    • T. F. Chan and L. A. Vese, "Active contours without edges," IEEE Trans. Image Proc., vol. 10, pp. 266-277, 2001.
    • (2001) IEEE Trans. Image Proc. , vol.10 , pp. 266-277
    • Chan, T.F.1    Vese, L.A.2
  • 11
    • 0036964396 scopus 로고    scopus 로고
    • A review on MR vascular image processing algorithms: Acquisition and prefiltering: Part I
    • Dec.
    • J. S. Suri, K. Liu, L. Reden, and S. Laxminarayan, "A review on MR vascular image processing algorithms: acquisition and prefiltering: part I," IEEE Trans. on Info. Tech. in Biomed., vol. 6, pp. 324-337, Dec. 2002.
    • (2002) IEEE Trans. on Info. Tech. in Biomed. , vol.6 , pp. 324-337
    • Suri, J.S.1    Liu, K.2    Reden, L.3    Laxminarayan, S.4
  • 12
    • 33846906253 scopus 로고    scopus 로고
    • Practical consideration about cost functions of spatial independent component analysis in medical image processing
    • M. Naganawa, Y. Kimura, Y. Manabe, and K. Chihara, "Practical consideration about cost functions of spatial independent component analysis in medical image processing," Proc. IEEE Eng. Med. Biol. Conf., pp. 1120-1122, 2005.
    • (2005) Proc. IEEE Eng. Med. Biol. Conf. , pp. 1120-1122
    • Naganawa, M.1    Kimura, Y.2    Manabe, Y.3    Chihara, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.