메뉴 건너뛰기




Volumn , Issue , 2009, Pages 3988-3994

LabPET inter-crystal scatter study using GATE

Author keywords

Detection efficiency; Energy threshold; GATE; Geant4; Inter crystal scatter (ICS); LabPET; PET; Simulation

Indexed keywords

ANGLE OF INCIDENCE; CRYSTAL SCATTERS; DETECTION EFFICIENCY; ENERGY THRESHOLDS; GEANT4 APPLICATION FOR TOMOGRAPHIC EMISSIONS; INCIDENCE ANGLES; OBLIQUE ANGLES; SPATIAL DISTRIBUTION;

EID: 77951179686     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5401936     Document Type: Conference Paper
Times cited : (7)

References (11)
  • 1
    • 0030167954 scopus 로고    scopus 로고
    • A Study of inter-crystal scatter in small scintillator arrays designed for high resolution PET imaging
    • Y. Shao, S. R. Cherry, S. Siegel, and R. W. Silverman. "A study of inter-crystal scatter in small scintillator arrays designed for high resolution PET imaging", IEEE Trans. Nucl. Sci., vol. 43, no. 3, pp. 1938-1944, 1996. (Pubitemid 126776023)
    • (1996) IEEE Transactions on Nuclear Science , vol.43 , Issue.3 PART 2 , pp. 1938-1944
    • Shao, Y.1    Cherry, S.R.2    Siegel, S.3    Silverman, R.W.4
  • 2
    • 60449085244 scopus 로고    scopus 로고
    • The hardware and signal processing architecture of LabPET™, a small animal APD-based digital PET scanner
    • R. Fontaine et al., "The hardware and signal processing architecture of LabPET™, a small animal APD-based digital PET scanner", IEEE Trans. Nucl. Sci., vol. 56, no. 1, pp. 3-9, 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.1 , pp. 3-9
    • Fontaine, R.1
  • 3
    • 60449097895 scopus 로고    scopus 로고
    • Performance evaluation of the LabPET™ APDbased digital PET scanner
    • M. Bergeron et al., "Performance evaluation of the LabPET™ APDbased digital PET scanner", IEEE Trans. Nucl. Sci., vol. 56, no. 1, pp. 10-16, 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.1 , pp. 10-16
    • Bergeron, M.1
  • 4
    • 42449141551 scopus 로고    scopus 로고
    • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction
    • I. Torres-Espallardo et al., "Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction" Phys. Med. Biol., vol. 53, no. 9, pp. 2391-2411, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , Issue.9 , pp. 2391-2411
    • Torres-Espallardo, I.1
  • 5
    • 5744251917 scopus 로고    scopus 로고
    • GATE: A simulation toolkit for PET and SPECT
    • S. Jan et al., "GATE: a simulation toolkit for PET and SPECT", Phys. Med. Biol., vol. 49, pp. 4543-4561, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4543-4561
    • Jan, S.1
  • 6
    • 0038377458 scopus 로고    scopus 로고
    • Geant4 - A simulation toolkit
    • S. Agostinelli et al., "Geant4 - a simulation toolkit", Nucl. Instr. Meth. Phys. Res. A, vol. 506, pp. 250-303, 2003.
    • (2003) Nucl. Instr. Meth. Phys. Res. A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 7
    • 27644584205 scopus 로고    scopus 로고
    • Comparison of Geant4 electromagnetic physics models against the NIST reference data
    • K. Amako et al., "Comparison of Geant4 electromagnetic physics models against the NIST reference data", IEEE Trans. Nucl. Sci., vol. 52, no. 4, pp. 910-918, 2005.
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , Issue.4 , pp. 910-918
    • Amako, K.1
  • 8
    • 61349124780 scopus 로고    scopus 로고
    • Characterization of scatter in cone-beam CT breast imaging: Comparison of experimental measurements and Monte Carlo simulation
    • Y. Chen et al., "Characterization of scatter in cone-beam CT breast imaging: comparison of experimental measurements and Monte Carlo simulation", Med. Phys., vol. 36, no. 3, pp. 857-869, 2009.
    • (2009) Med. Phys. , vol.36 , Issue.3 , pp. 857-869
    • Chen, Y.1
  • 9
    • 72349100289 scopus 로고    scopus 로고
    • Development and validation of a GATE simulation model for the LabPET scanner
    • in Press
    • S. Rechka, R. Fontaine, M. Rafecas, and R. Lecomte, "Development and validation of a GATE simulation model for the LabPET scanner", IEEE Trans. Nucl. Sci., vol. 56, no. 6, in Press, 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.6
    • Rechka, S.1    Fontaine, R.2    Rafecas, M.3    Lecomte, R.4
  • 11
    • 0030211634 scopus 로고    scopus 로고
    • Algorithms to identify detector Compton scatter in PET modules
    • K. A. Comanor, P. R. G. Virador, and W. W. Moses, "Algorithms to identify detector Compton scatter in PET modules", IEEE Trans. Nucl. Sci., vol. 43, no. 4, pp. 2213-2218, 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.4 , pp. 2213-2218
    • Comanor, K.A.1    Virador, P.R.G.2    Moses, W.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.