메뉴 건너뛰기




Volumn 53, Issue 9, 2008, Pages 2391-2411

Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction

Author keywords

[No Author keywords available]

Indexed keywords

APPROXIMATION THEORY; COMPUTER SIMULATION; CRYSTALS; ESTIMATION; IMAGE ANALYSIS;

EID: 42449141551     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/9/012     Document Type: Article
Times cited : (22)

References (19)
  • 1
    • 2942748643 scopus 로고    scopus 로고
    • Monte Carlo simulation in PET and SPECT instrumentation using GATE
    • Assié K et al 2004 Monte Carlo simulation in PET and SPECT instrumentation using GATE Nucl. Instrum. Methods Phys. Res. A 527 180-9
    • (2004) Nucl. Instrum. Methods Phys. Res. , vol.527 , Issue.1-2 , pp. 180-189
    • Al Et, A.K.1
  • 3
    • 20644460816 scopus 로고    scopus 로고
    • Correction methods for random coincidences in fully 3D whole-body PET: Impact on data and image quality
    • Brasse D, Kinahan P E, Lartizien C, Comtat C, Casey M and Morel C 2005 Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality J. Nucl. Med. 46 859-67
    • (2005) J. Nucl. Med. , vol.46 , Issue.5 , pp. 859-867
    • Brasse, D.1    Kinahan, P.E.2    Lartizien, C.3    Comtat, C.4    Casey, M.5    Morel, C.6
  • 4
    • 22844452107 scopus 로고    scopus 로고
    • Attenuation correction for small animal PET tomographs
    • Chow P L, Rannou F R and Chatziioannou A F 2005 Attenuation correction for small animal PET tomographs Phys. Med. Biol. 50 1837-50
    • (2005) Phys. Med. Biol. , vol.50 , Issue.8 , pp. 1837-1850
    • Chow, P.L.1    Rannou, F.R.2    Chatziioannou, A.F.3
  • 6
    • 0019524035 scopus 로고
    • Quantitation in positron-emission computed tomography: 4. Effect of accidental coincidences
    • Hoffman E J, Huang S, Phelps M E and Kuhl D E 1981 Quantitation in positron-emission computed tomography: 4. Effect of accidental coincidences J. Comput. Assist. Tomography 5 391-400
    • (1981) J. Comput. Assist. Tomography , vol.5 , pp. 391-400
    • Hoffman, E.J.1    Huang, S.2    Phelps, M.E.3    Kuhl, D.E.4
  • 8
    • 22244440239 scopus 로고    scopus 로고
    • A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout
    • McElroy D P, Hoose M, Pimpl W, Spanoudaki V, Schuler T and Ziegler S I 2005a A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout Phys. Med. Biol. 50 3323-35
    • (2005) Phys. Med. Biol. , vol.50 , Issue.14 , pp. 3323-3335
    • McElroy, D.P.1    Hoose, M.2    Pimpl, W.3    Spanoudaki, V.4    Schuler, T.5    Ziegler, S.I.6
  • 9
    • 17644367489 scopus 로고    scopus 로고
    • Characterization and readout of MADPET-iI detector modules: Validation of a unique design concept for high-resolution small animal PET
    • McElroy D P, Pimpl W, Pichler B J, Rafecas M, Schuler T and Ziegler S I 2005b Characterization and readout of MADPET-iI detector modules: validation of a unique design concept for high-resolution small animal PET IEEE Trans. Nucl. Sci. 52 199-204
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , Issue.1 , pp. 199-204
    • McElroy, D.P.1    Pimpl, W.2    Pichler, B.J.3    Rafecas, M.4    Schuler, T.5    Ziegler, S.I.6
  • 11
    • 0026121689 scopus 로고
    • Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography
    • Politte D G and Snyder D L 1991 Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography IEEE Trans. Med. Imaging 10 82-9
    • (1991) IEEE Trans. Med. Imaging , vol.10 , Issue.1 , pp. 82-89
    • Politte, D.G.1    Snyder, D.L.2
  • 12
  • 15
    • 26244444788 scopus 로고    scopus 로고
    • Statistical dynamic image reconstruction in state-of-the-art high-resolution PET
    • Rahmim A, Cheng J Ch, Blinder S, Camborde M L and Sossi V 2005 Statistical dynamic image reconstruction in state-of-the-art high-resolution PET Phys. Med. Biol. 50 4887-912
    • (2005) Phys. Med. Biol. , vol.50 , Issue.20 , pp. 4887-4912
    • Rahmim, A.1    Ch, C.J.2    Blinder, S.3    Camborde, M.L.4    Sossi, V.5
  • 16
    • 33745889310 scopus 로고    scopus 로고
    • An analog signal processing ASIC for a small animal LSO-APD PET tomograph
    • Spanoudaki V Ch, McElroy D P and Ziegler S I 2006 An analog signal processing ASIC for a small animal LSO-APD PET tomograph Nucl. Instrum. Methods Phys. Res. A 564 451-62
    • (2006) Nucl. Instrum. Methods Phys. Res. , vol.564 , Issue.1 , pp. 451-462
    • Ch, S.V.1    McElroy, D.P.2    Ziegler, S.I.3
  • 19
    • 0036680311 scopus 로고    scopus 로고
    • Mean and variance of coincidence counting with deadtime
    • Yu D F and Fessler J A 2002 Mean and variance of coincidence counting with deadtime Nucl. Instrum. Methods Phys. Res. A 488 362-74
    • (2002) Nucl. Instrum. Methods Phys. Res. , vol.488 , Issue.1-2 , pp. 362-374
    • Yu, D.F.1    Fessler, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.