메뉴 건너뛰기




Volumn 43, Issue 3 PART 2, 1996, Pages 1938-1944

A Study of inter-crystal scatter in small scintillator arrays designed for high resolution PET imaging

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BISMUTH COMPOUNDS; COMPUTER SIMULATION; CRYSTALS; MONTE CARLO METHODS; OPTICAL RESOLVING POWER; PHOTONS; POSITRON EMISSION TOMOGRAPHY; RADIATION DETECTORS;

EID: 0030167954     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/23.507250     Document Type: Article
Times cited : (111)

References (8)
  • 1
    • 0030166382 scopus 로고    scopus 로고
    • Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging
    • to be published
    • S.R. Cherry, Y. Shao, S. Siegel, R.W. Silverman, "Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging," IEEE Trans. Nucl. Sci., 1996 (to be published)
    • (1996) IEEE Trans. Nucl. Sci.
    • Cherry, S.R.1    Shao, Y.2    Siegel, S.3    Silverman, R.W.4
  • 2
    • 0027644024 scopus 로고
    • Performance of a PET module utilizing an array of silicon photodiodes to identify the crystal of interaction
    • W.W. Moses, S.E. Derenzo, R. Nutt, "Performance of a PET module utilizing an array of silicon photodiodes to identify the crystal of interaction," IEEE Trans. Nucl. Sci., Vol.40, pp.1036-1040, 1993
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1036-1040
    • Moses, W.W.1    Derenzo, S.E.2    Nutt, R.3
  • 3
    • 0020702969 scopus 로고
    • Geometry study of a high resolution PET detection system using small detectors
    • R. Lecomte, D. Schmitt, L. Lamoureut, "Geometry study of a high resolution PET detection system using small detectors," IEEE Trans. Nucl. Sci., Vol.31, pp.556-561, 1984
    • (1984) IEEE Trans. Nucl. Sci. , vol.31 , pp. 556-561
    • Lecomte, R.1    Schmitt, D.2    Lamoureut, L.3
  • 4
    • 0026902676 scopus 로고
    • Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator
    • C.L. Melcher and J.S. Schweitzer, "Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator," IEEE Trans. Nucl Sci,. Vol.39, pp. 502-505, 1992.
    • (1992) IEEE Trans. Nucl Sci. , vol.39 , pp. 502-505
    • Melcher, C.L.1    Schweitzer, J.S.2
  • 5
    • 0000727366 scopus 로고
    • Light collection in scintillating detector composites for neutron detection
    • G.F. Knoll, T.F. Knoll, T.M. Henderson, "Light collection in scintillating detector composites for neutron detection," IEEE Trans. Nucl. Sci., Vol.35, pp.872-875, 1988
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , pp. 872-875
    • Knoll, G.F.1    Knoll, T.F.2    Henderson, T.M.3
  • 7
    • 84939045331 scopus 로고
    • A multicrystal two dimensional BGO detector system for positron emission tomography
    • M.E. Casey and R. Nutt, "A multicrystal two dimensional BGO detector system for positron emission tomography," IEEE Trans. Nucl. Sci. , Vol.33, pp. 460-463, 1986.
    • (1986) IEEE Trans. Nucl. Sci. , vol.33 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.