Volumn 55, Issue 9, 2010, Pages 2709-2726

Simulation-based evaluation and optimization of a new CdZnTe gamma-camera architecture (HiSens)

Author keywords

[No Author keywords available]

Indexed keywords

3D LOCALIZATION; ANGER CAMERA; CZT DETECTORS; DEPTH-OF-INTERACTION INFORMATIONS; DETECTIVE QUANTUM EFFICIENCY; EXPERIMENTAL DATA; GAMMA-CAMERA; HIGH-APERTURE; MONTE CARLO SIMULATION; PARALLEL HOLE COLLIMATORS; PIXELIZATION; PLANAR IMAGING; RECONSTRUCTION ALGORITHMS; SIMULATION-BASED; SPATIAL RESOLUTION; SYSTEM SENSITIVITY; TOMOGRAPHIC;

EID: 77951173361     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/9/019     Document Type: Article
Times cited : (28)

References (18)
  • 2
    • 0342626638 scopus 로고    scopus 로고
    • Applications of semiconductor detectors to nuclear medicine
    • Barber H B 1999 Applications of semiconductor detectors to nuclear medicine Nucl. Instrum. Methods A 436 102-10
    • (1999) Nucl. Instrum. Methods , vol.436 , pp. 102-110
    • Barber, H.B.1
  • 3
    • 0000356133 scopus 로고    scopus 로고
    • Signal-to-noise optimization of medical imaging systems
    • Cunningham I A and Shaw R 1999 Signal-to-noise optimization of medical imaging systems J. Opt. Soc. Am. A 16 621-32
    • (1999) J. Opt. Soc. Am. , vol.16 , pp. 621-632
    • Cunningham, I.A.1    Shaw, R.2
  • 4
    • 0030263181 scopus 로고    scopus 로고
    • Current state-of-art industrial and research applications using room-temperature CdTe and CdZnTe solid state detectors
    • Eisen Y 1996 Current state-of-art industrial and research applications using room-temperature CdTe and CdZnTe solid state detectors Nucl. Instrum. Methods A 380 431-9
    • (1996) Nucl. Instrum. Methods , vol.380 , pp. 431-439
    • Eisen, Y.1
  • 5
    • 0036702954 scopus 로고    scopus 로고
    • NUCAM3 a gamma camera based on segmented monolithic CdZnTe detectors
    • Eisen Y, Mardor I and Shor A 2002 NUCAM3 a gamma camera based on segmented monolithic CdZnTe detectors IEEE Trans. Nucl. Sci. 49 1728-32
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 1728-1732
    • Eisen, Y.1    Mardor, I.2    Shor, A.3
  • 7
    • 45849149685 scopus 로고    scopus 로고
    • A new architecture for pixellated solid state gamma camera used in nuclear medicine
    • Guérin L, Verger L, Rebuffel V and Monnet O 2008 A new architecture for pixellated solid state gamma camera used in nuclear medicine IEEE Trans. Nucl. Sci. 55 1573-80
    • (2008) IEEE Trans. Nucl. Sci. , vol.55 , pp. 1573-1580
    • Guérin, L.1    Verger, L.2    Rebuffel, V.3    Monnet, O.4
  • 9
    • 0028700063 scopus 로고
    • Accelerated image-reconstruction using ordered subsets of projection data
    • Hudson H M and Larkin R S 1994 Accelerated image-reconstruction using ordered subsets of projection data IEEE Trans. Med. Imaging 13 601-9
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 10
    • 5744251917 scopus 로고    scopus 로고
    • GATE: A simulation toolkit for PET and SPECT
    • Jan S et al 2004 GATE: a simulation toolkit for PET and SPECT Phys. Med. Biol. 49 4543-61
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4543-4561
    • Jan, S.1
  • 12
    • 0035250743 scopus 로고    scopus 로고
    • Medical applications of CdTe and CdZnTe detectors
    • Scheiber C and Giakos G C 2001 Medical applications of CdTe and CdZnTe detectors Nucl. Instrum. Methods A 458 12-25
    • (2001) Nucl. Instrum. Methods , vol.458 , pp. 12-25
    • Scheiber, C.1    Giakos, G.C.2
  • 13
    • 17144379734 scopus 로고    scopus 로고
    • The use of detective quantum efficiency (DQE) in evaluating the performance of gamma camera systems
    • Starck S, Bath M and Carlsson S 2005 The use of detective quantum efficiency (DQE) in evaluating the performance of gamma camera systems Phys. Med. Biol. 50 1601-9
    • (2005) Phys. Med. Biol. , vol.50 , pp. 1601-1609
    • Starck, S.1    Bath, M.2    Carlsson, S.3
  • 14
    • 2342571615 scopus 로고    scopus 로고
    • Combination of high resolution analytically computed uncollided flux images with low resolution Monte Carlo computed scattered flux images
    • Tabary J, Guillemaud R and Mathy F 2004 Combination of high resolution analytically computed uncollided flux images with low resolution Monte Carlo computed scattered flux images IEEE Trans. Nucl. Sci. 51 212-7
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 212-217
    • Tabary, J.1    Guillemaud, R.2    Mathy, F.3
  • 15
    • 0000164906 scopus 로고    scopus 로고
    • New developments in CdTe and CdZnTe detectors for x and gamma-ray applications
    • Verger L, Bonnefoy J P, Glasser F and Ouvrier-Buffet P 1997 New developments in CdTe and CdZnTe detectors for x and gamma-ray applications J. Electron. Mater. 26 738-44
    • (1997) J. Electron. Mater. , vol.26 , pp. 738-744
    • Verger, L.1    Bonnefoy, J.P.2    Glasser, F.3    Ouvrier-Buffet, P.4
  • 17
    • 0037679314 scopus 로고    scopus 로고
    • Planar image quality comparison between a CdZnTe prototype and a standard NaI(Tl) gamma camera
    • Wagenaar D J, Chowdhury S, Engdahl J C and Burckhardt D D 2003 Planar image quality comparison between a CdZnTe prototype and a standard NaI(Tl) gamma camera Nucl. Instrum Methods A 505 586-9
    • (2003) Nucl. Instrum Methods , vol.505 , pp. 586-589
    • Wagenaar, D.J.1    Chowdhury, S.2    Engdahl, J.C.3    Burckhardt, D.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.