1
-
-
4244180299
-
Charge transport in arrays of semiconductor gamma-ray detectors
-
H. H. Barrett, J. D. Eskin, and B. B. Barber, "Charge transport in arrays of semiconductor gamma-ray detectors," Phys. Rev, Lett., vol. 75, no. 1, pp. 156-159, 1995.
-
(1995)
Phys. Rev, Lett.
, vol.75
, Issue.1
, pp. 156-159
-
-
Barrett, H.H.1
Eskin, J.D.2
Barber, B.B.3
-
2
-
-
0030264926
-
Progress in developing focal-plane-multiplexer readout for large CdZnTe arrays for nuclear medicine applications
-
H. B. Barber et al., "Progress in developing focal-plane-multiplexer readout for large CdZnTe arrays for nuclear medicine applications," Nucl. Instr. Meth. A, vol. 380, pp. 262-265, 1996.
-
(1996)
Nucl. Instr. Meth. A
, vol.380
, pp. 262-265
-
-
Barber, H.B.1
-
3
-
-
3342977311
-
CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
-
Y. Eisen, A. Shor, and I. Mardor, "CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems," IEEE Trans. Nucl. Sci., vol. 51, pp. 1191-1198, 2004.
-
(2004)
IEEE Trans. Nucl. Sci.
, vol.51
, pp. 1191-1198
-
-
Eisen, Y.1
Shor, A.2
Mardor, I.3
-
4
-
-
33144472211
-
A three-dimensional model of CdZnTe gamma-ray detector: Experimental validation
-
submitted for publication
-
F. Mathy, A. Glière, E. G. d'Aillon, P. Massé, M. Picone, J. Tabary, and L. Verger, "A three-dimensional model of CdZnTe gamma-ray detector: Experimental validation," IEEE Trans. Nucl. Sci., submitted for publication.
-
IEEE Trans. Nucl. Sci.
-
-
Mathy, F.1
Glière, A.2
D'Aillon, E.G.3
Massé, P.4
Picone, M.5
Tabary, J.6
Verger, L.7
-
5
-
-
0021490404
-
Modeling of continuous media methodology and computer aided design of finite element programs
-
P. Massé, "Modeling of continuous media methodology and computer aided design of finite element programs," IEEE Trans. Magn., vol. 20, no. 5, pp. 1885-1890, 1984.
-
(1984)
IEEE Trans. Magn.
, vol.20
, Issue.5
, pp. 1885-1890
-
-
Massé, P.1
-
6
-
-
0001063121
-
Method for mapping charge pulses in semiconductor radiation detectors
-
T. H. Prettyman, "Method for mapping charge pulses in semiconductor radiation detectors," Nucl. Instr. Meth. A, vol. 422, pp. 232-237, 1999.
-
(1999)
Nucl. Instr. Meth. A
, vol.422
, pp. 232-237
-
-
Prettyman, T.H.1
-
7
-
-
0031274705
-
An algorithm for monte carlo simulation of the coupled electron-photon transport
-
J. Sempau, E. Acosta, J. Baro, J. M. Fernandez-Varea, and F. Salvat, "An algorithm for monte carlo simulation of the coupled electron-photon transport," Nucl. Instr. Meth. B, vol. 132, pp. 377-390, 1997.
-
(1997)
Nucl. Instr. Meth. B
, vol.132
, pp. 377-390
-
-
Sempau, J.1
Acosta, E.2
Baro, J.3
Fernandez-Varea, J.M.4
Salvat, F.5
-
8
-
-
0030259462
-
Electrode configuration and energy resolution in gamma-ray detectors
-
P. N. Luke, "Electrode configuration and energy resolution in gamma-ray detectors," Nucl Instr. Meth. A, vol. 380, no. 1-2, pp. 232-237, 1996.
-
(1996)
Nucl Instr. Meth. A
, vol.380
, Issue.1-2
, pp. 232-237
-
-
Luke, P.N.1
-
9
-
-
19944363491
-
Performances and perspectives of a CdZnTe-based gamma camera for medical imaging
-
L. Verger, M. C. Gentet, L. Gerfault, R. Guillemaud, C. Mestais, O. Monnet, G. Montémont, G. Petroz, J. P. Rostaing, and J. Rustique, "Performances and perspectives of a CdZnTe-based gamma camera for medical imaging," IEEE Trans. Nucl. Sci., vol. 51, pp. 3111-3117, 2004.
-
(2004)
IEEE Trans. Nucl. Sci.
, vol.51
, pp. 3111-3117
-
-
Verger, L.1
Gentet, M.C.2
Gerfault, L.3
Guillemaud, R.4
Mestais, C.5
Monnet, O.6
Montémont, G.7
Petroz, G.8
Rostaing, J.P.9
Rustique, J.10
-
10
-
-
0343738891
-
Growth and characterization of CdTe single crystals for radiation detectors
-
M. Funaki, T. Ozaki, K. Satoh, and R. Ohno, "Growth and characterization of CdTe single crystals for radiation detectors," Nucl. Instr. Meth. A, vol. 436, pp. 120-126, 1999.
-
(1999)
Nucl. Instr. Meth. A
, vol.436
, pp. 120-126
-
-
Funaki, M.1
Ozaki, T.2
Satoh, K.3
Ohno, R.4
-
11
-
-
0030260623
-
1-D position sensitive single carrier semiconductor detectors
-
Z. He, G. Knoll, D. Wehe, R. Rojeski, C. H. Mastrangelo, M. Hammig, C. Barrett, and A. Uritani, "1-D position sensitive single carrier semiconductor detectors," Nucl. Intstr. Meth. A, vol. 380, pp. 228-231, 1996.
-
(1996)
Nucl. Intstr. Meth. A
, vol.380
, pp. 228-231
-
-
He, Z.1
Knoll, G.2
Wehe, D.3
Rojeski, R.4
Mastrangelo, C.H.5
Hammig, M.6
Barrett, C.7
Uritani, A.8
-
12
-
-
0035251271
-
Spectroscopy with pixelated CdZnTe gamma detectors-Experiment versus theory
-
A. Shor, Y. Eisen, and I. Mardor, "Spectroscopy with pixelated CdZnTe gamma detectors-Experiment versus theory," Nucl. Instr. Meth. A, vol. 458, pp. 47-54, 2001.
-
(2001)
Nucl. Instr. Meth. A
, vol.458
, pp. 47-54
-
-
Shor, A.1
Eisen, Y.2
Mardor, I.3
-
13
-
-
0030263452
-
A CdTe gamma-camera for the space observatory INTEGRAL: Software chargeloss corrections
-
F. Lebrun, J. -P. Leray, P. Laurent, P. D. Antoni, and C. Blondel, "A CdTe gamma-camera for the space observatory INTEGRAL: Software chargeloss corrections," Nucl. Instr. Meth. A, vol. 380, no. 1-2, pp. 414-418, 1996.
-
(1996)
Nucl. Instr. Meth. A
, vol.380
, Issue.1-2
, pp. 414-418
-
-
Lebrun, F.1
Leray, J.P.2
Laurent, P.3
Antoni, P.D.4
Blondel, C.5
-
14
-
-
0344240890
-
Charge loss between contacts of CdZnTe pixel detectors
-
A. E. Bolotnikov, W. R. Cook, F. A. Harrison, A. -S. Wong, S. M. Schindler, and A. C. Eichelberger, "Charge loss between contacts of CdZnTe pixel detectors," Nucl. Intstr. Meth., vol. 432, pp. 326-331, 1999.
-
(1999)
Nucl. Intstr. Meth.
, vol.432
, pp. 326-331
-
-
Bolotnikov, A.E.1
Cook, W.R.2
Harrison, F.A.3
Wong, A.S.4
Schindler, S.M.5
Eichelberger, A.C.6
-
15
-
-
18644381735
-
Electron trapping nonuniformity in high-pressure-Bridgman-grown CdZnTe
-
M. Amman, J. S. Lee, and P. N. Luke, "Electron trapping nonuniformity in high-pressure-Bridgman-grown CdZnTe," J. Appl. Phys., vol. 6, no. 92, pp. 3198-3206, 2002.
-
(2002)
J. Appl. Phys.
, vol.6
, Issue.92
, pp. 3198-3206
-
-
Amman, M.1
Lee, J.S.2
Luke, P.N.3
|