메뉴 건너뛰기




Volumn 49 I, Issue 4, 2002, Pages 1728-1732

NUCAM3 - A gamma camera based on segmented monolithic CdZnTe detectors

Author keywords

Cadmium zinc telluride; Detector analysis; Gamma camera

Indexed keywords

CADMIUM COMPOUNDS; CAMERAS; GAMMA RAYS; IMAGE SEGMENTATION; SPURIOUS SIGNAL NOISE;

EID: 0036702954     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2002.801532     Document Type: Article
Times cited : (30)

References (9)
  • 2
    • 0032099857 scopus 로고    scopus 로고
    • CdZnTe solid-state gamma camera
    • June
    • J.F. Butler et al., "CdZnTe solid-state gamma camera," IEEE Trans. Nucl. Sci., vol. 45, pp. 359-363, June 1998.
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , pp. 359-363
    • Butler, J.F.1
  • 3
    • 0035250737 scopus 로고    scopus 로고
    • A new design for high resolution, high efficiency CZT gamma camera detector
    • C. Mestais et al., "A new design for high resolution, high efficiency CZT gamma camera detector," Nucl. Instrum. Methods, vol. A458, pp. 62-67, 2001.
    • (2001) Nucl. Instrum. Methods , vol.A458 , pp. 62-67
    • Mestais, C.1
  • 4
    • 0033688156 scopus 로고    scopus 로고
    • A pixellated gamma-camera based on CdTe detectors clinical interests and performances
    • J. Chambron et al., "A pixellated gamma-camera based on CdTe detectors clinical interests and performances," Nucl. Instrum. Methods, vol. A448, pp. 537-549, 2000.
    • (2000) Nucl. Instrum. Methods , vol.A448 , pp. 537-549
    • Chambron, J.1
  • 5
    • 0035250743 scopus 로고    scopus 로고
    • Medical applications of CdTe and CdZnTe detectors
    • C. Scheiber and G.C. Giakos, "Medical applications of CdTe and CdZnTe detectors," Nucl. Instram. Methods, vol. A458, pp. 12-25, 2001.
    • (2001) Nucl. Instram. Methods , vol.A458 , pp. 12-25
    • Scheiber, C.1    Giakos, G.C.2
  • 6
    • 0011398626 scopus 로고    scopus 로고
    • Evaluation of a small CZT detector for scintimammography
    • Toronto, ON, Canada
    • M.K. O'Connor, B. Mueller, and I. Blevis, "Evaluation of a small CZT detector for scintimammography," in SNM 2001, Toronto, ON, Canada.
    • (2001) SNM
    • O'Connor, M.K.1    Mueller, B.2    Blevis, I.3
  • 7
    • 0032673875 scopus 로고    scopus 로고
    • CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    • Y. Eisen, A. Shor, and I. Mardor, "CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems," Nucl. Instrum. Methods, vol. A428, pp. 158-170, 1999.
    • (1999) Nucl. Instrum. Methods , vol.A428 , pp. 158-170
    • Eisen, Y.1    Shor, A.2    Mardor, I.3
  • 8
    • 0032685817 scopus 로고    scopus 로고
    • Optimum spectroscopic performance from CZT gamma- and x-ray detectors with pad and strip segmentation
    • A. Shor, Y. Eisen, and I. Mardor, "Optimum spectroscopic performance from CZT gamma- and x-ray detectors with pad and strip segmentation," Nucl. Instrum. Methods, vol. A428, pp. 182-192, 1999.
    • (1999) Nucl. Instrum. Methods , vol.A428 , pp. 182-192
    • Shor, A.1    Eisen, Y.2    Mardor, I.3
  • 9
    • 0035428710 scopus 로고    scopus 로고
    • Edge and corner effects on spectra of segmented CdZnTe detectors
    • Aug.
    • I. Mardor, A. Shor, and Y. Eisen, "Edge and corner effects on spectra of segmented CdZnTe detectors," IEEE Trans. Nucl. Sci., vol. 48, pp. 1033-1040, Aug. 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 1033-1040
    • Mardor, I.1    Shor, A.2    Eisen, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.