메뉴 건너뛰기




Volumn , Issue , 2009, Pages 3199-3204

TASER conducted electrical weapons and implanted pacemakers and defibrillators

Author keywords

CEW; Electrophysiology; ICDs; Pacemakers; TASER

Indexed keywords

ELECTROPHYSIOLOGY; IMPLANTABLE CARDIOVERTER DEFIBRILLATORS; PACEMAKERS;

EID: 77950984876     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5333136     Document Type: Conference Paper
Times cited : (19)

References (17)
  • 2
    • 77952250966 scopus 로고    scopus 로고
    • Less Lethal Weapon Effectiveness, Use of Force, and Suspect & Officer Injuries: A Five-Year Analysis
    • Mesloh C, Henych M, Wolf R. Less Lethal Weapon Effectiveness, Use of Force, and Suspect & Officer Injuries: A Five-Year Analysis. Report to the National Institute of Justice 2008.
    • (2008) Report to the National Institute of Justice
    • Mesloh, C.1    Henych, M.2    Wolf, R.3
  • 3
    • 34249007454 scopus 로고    scopus 로고
    • Duration of discharge of neuromuscular incapacitating device and inappropriate implantable cardioverter-defibrillator detections
    • Images in cardiovascular medicine
    • Calton R, Cameron D, Masse S, Nanthakumar K. Images in cardiovascular medicine. Duration of discharge of neuromuscular incapacitating device and inappropriate implantable cardioverter-defibrillator detections. Circulation 2007;115:e472-4.
    • (2007) Circulation , vol.115
    • Calton, R.1    Cameron, D.2    Masse, S.3    Nanthakumar, K.4
  • 4
    • 34447633733 scopus 로고    scopus 로고
    • Taser-induced rapid ventricular myocardial capture demonstrated by pacemaker intracardiac electrograms
    • Cao M, Shinbane JS, Gillberg JM, Saxon LA, Swerdlow CD. Taser-induced rapid ventricular myocardial capture demonstrated by pacemaker intracardiac electrograms. J Cardiovasc Electro-physiol 2007;18:876-879
    • (2007) J Cardiovasc Electro-physiol , vol.18 , pp. 876-879
    • Cao, M.1    Shinbane, J.S.2    Gillberg, J.M.3    Saxon, L.A.4    Swerdlow, C.D.5
  • 5
    • 33144463330 scopus 로고    scopus 로고
    • Effect of a Taser shot to the chest of a patient with an implantable defibrillator
    • Haegeli LM, Sterns LD, Adam DC, Leather RA. Effect of a Taser shot to the chest of a patient with an implantable defibrillator. Heart Rhythm 2006;3:339-341
    • (2006) Heart Rhythm , vol.3 , pp. 339-341
    • Haegeli, L.M.1    Sterns, L.D.2    Adam, D.C.3    Leather, R.A.4
  • 6
    • 77951018029 scopus 로고    scopus 로고
    • Can Electrical-Conductive Weapons (TASER®) alter the functional integrity of pace-makers and defibrillators and cause rapid myocar-dial capture?
    • Lakkireddy D, Biria M, Baryun E, Berenbom L, Pimentel R, Emert M, Kreighbaum K, Kroll M, Verma A. Can Electrical-Conductive Weapons (TASER®) alter the functional integrity of pace-makers and defibrillators and cause rapid myocar-dial capture? . Heart Rhythm 2008;5:S97.
    • (2008) Heart Rhythm , vol.5
    • Lakkireddy, D.1    Biria, M.2    Baryun, E.3    Berenbom, L.4    Pimentel, R.5    Emert, M.6    Kreighbaum, K.7    Kroll, M.8    Verma, A.9
  • 7
    • 62849118692 scopus 로고    scopus 로고
    • Physiology and pathology of TASER electronic control devices
    • Kroll M. Physiology and pathology of TASER electronic control devices. J Forensic Legal Med 2009.
    • (2009) J Forensic Legal Med
    • Kroll, M.1
  • 8
    • 77950970843 scopus 로고    scopus 로고
    • TASER® Electronic Control Devices
    • Fish R, Geddes L, eds. Tucson, AZ: Lawyers and Judges Publishing Company, Inc.
    • Kroll M. TASER® Electronic Control Devices. In: Fish R, Geddes L, eds. Electrical Injuries: Medical and Bioengineering Aspects. Tucson, AZ: Lawyers and Judges Publishing Company, Inc., 2009:455-491.
    • (2009) Electrical Injuries: Medical and Bioengineering Aspects , pp. 455-491
    • Kroll, M.1
  • 9
    • 77951013861 scopus 로고
    • International Electrotechnical Commission
    • Geneva, Switzerland: In-ternational Electrotechnical Commission
    • International Electrotechnical Commission. Medical Electrical Equipment, Part 1: General Requirement for Safety. Geneva, Switzerland: In-ternational Electrotechnical Commission, 1988.
    • (1988) Medical Electrical Equipment, Part 1: General Requirement for Safety
  • 16
    • 53749096485 scopus 로고    scopus 로고
    • A randomized trial of the effect of automated ventricular capture on de-vice longevity and threshold measurement in pacemaker patients
    • Koplan BA, Gilligan DM, Nguyen LS, Lau TK, Thackeray LM, Berg KC. A randomized trial of the effect of automated ventricular capture on de-vice longevity and threshold measurement in pacemaker patients. Pacing Clin Electrophysiol 2008;31:1467-1474
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1467-1474
    • Koplan, B.A.1    Gilligan, D.M.2    Nguyen, L.S.3    Lau, T.K.4    Thackeray, L.M.5    Berg, K.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.