메뉴 건너뛰기




Volumn 18, Issue 8, 2007, Pages 876-879

Taser-induced rapid ventricular myocardial capture demonstrated by pacemaker intracardiac electrograms

Author keywords

Conducted energy devices; Intracardiac electrograms; Myocardial capture; Pacemaker; Taser

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL HEART PACEMAKER; CASE REPORT; CONDUCTED ENERGY DEVICE; DEVICE; ELECTROCARDIOGRAM; ELECTROGRAPHY; ENERGY TRANSFER; HEART MUSCLE; HEART PACING; HEART VENTRICLE; HUMAN; MALE; MYOCARDIAL DISEASE; MYOCARDIUM CAPTURE; PRIORITY JOURNAL; TASER;

EID: 34447633733     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2007.00881.x     Document Type: Article
Times cited : (63)

References (15)
  • 1
    • 33144474659 scopus 로고    scopus 로고
    • Stun guns: A new source of electromagnetic interference for implanted cardiac devices
    • Marine JE : Stun guns: A new source of electromagnetic interference for implanted cardiac devices. Heart Rhythm 2006 3 : 342 344.
    • (2006) Heart Rhythm , vol.3 , pp. 342-344
    • Marine, J.E.1
  • 2
    • 34447617466 scopus 로고    scopus 로고
    • 167 cases of death following stun-gun use
    • Anglen R : 167 cases of death following stun-gun use. Arizona Republic January 5, 2006.
    • (2006) Arizona Republic
    • Anglen, R.1
  • 4
    • 34447626910 scopus 로고    scopus 로고
    • http://www.taser.com
    • Taser. http://www2.taser.com/products/consumers/Pages/TASERX26C.aspx. http://www.taser.com
    • Taser1
  • 8
    • 33144463330 scopus 로고    scopus 로고
    • Effect of a Taser shot to the chest of a patient with an implantable defibrillator
    • Haegeli LM, Sterns LD, Adam DC, Leather RA : Effect of a Taser shot to the chest of a patient with an implantable defibrillator. Heart Rhythm 2006 3 : 339 341.
    • (2006) Heart Rhythm , vol.3 , pp. 339-341
    • Haegeli, L.M.1    Sterns, L.D.2    Adam, D.C.3    Leather, R.A.4
  • 9
    • 24044451579 scopus 로고    scopus 로고
    • Ventricular fibrillation after stun-gun discharge
    • Kim PJ, Franklin WH : Ventricular fibrillation after stun-gun discharge. N Engl J Med 2005 353 : 958 959.
    • (2005) N Engl J Med , vol.353 , pp. 958-959
    • Kim, P.J.1    Franklin, W.H.2
  • 10
    • 33646747618 scopus 로고    scopus 로고
    • Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults
    • Ho JD, Miner JR, Lakireddy DR, Bultman LL, Heegaard WG : Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med 2006 13 : 589 595.
    • (2006) Acad Emerg Med , vol.13 , pp. 589-595
    • Ho, J.D.1    Miner, J.R.2    Lakireddy, D.R.3    Bultman, L.L.4    Heegaard, W.G.5
  • 12
    • 0025753911 scopus 로고
    • Effects of the Taser in fatalities involving police confrontation
    • Kornblum RN, Reddy SK : Effects of the Taser in fatalities involving police confrontation. J Forensic Sci 1991 36 : 434 438.
    • (1991) J Forensic Sci , vol.36 , pp. 434-438
    • Kornblum, R.N.1    Reddy, S.K.2
  • 13
    • 0026755324 scopus 로고
    • Discussion of effects of the Taser in fatalities involving police confrontation
    • Allen TB : Discussion of effects of the Taser in fatalities involving police confrontation. J Forensic Sci 1992 37 : 956 958.
    • (1992) J Forensic Sci , vol.37 , pp. 956-958
    • Allen, T.B.1
  • 14
    • 7444248559 scopus 로고    scopus 로고
    • Electromagnetic interference in cardiac rhythm management devices
    • Sweesy MW, Holland JL, Smith KW : Electromagnetic interference in cardiac rhythm management devices. AACN Clin Issues 2004 15 : 391 403.
    • (2004) AACN Clin Issues , vol.15 , pp. 391-403
    • Sweesy, M.W.1    Holland, J.L.2    Smith, K.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.