-
1
-
-
0025984292
-
Fatigue failure of the sliding screw in hip fracture fixation: a report of three cases
-
Spivak J.M., Zuckerman J.D., Kummer F.J., Frankel V.H. Fatigue failure of the sliding screw in hip fracture fixation: a report of three cases. J Orthop Trauma 1991, 5:325-331.
-
(1991)
J Orthop Trauma
, vol.5
, pp. 325-331
-
-
Spivak, J.M.1
Zuckerman, J.D.2
Kummer, F.J.3
Frankel, V.H.4
-
2
-
-
1542268366
-
Performance study of braided carbon/PEEK composite compression bone plates
-
Fujihara K. Performance study of braided carbon/PEEK composite compression bone plates. Biomaterials 2004, 25:3877-3885.
-
(2004)
Biomaterials
, vol.25
, pp. 3877-3885
-
-
Fujihara, K.1
-
3
-
-
0037299805
-
Strain distribution analysis of braided composite bone plates
-
Veerabagu S., Fujihara K., Dasari G.R., Ramakrishna S. Strain distribution analysis of braided composite bone plates. Compos Sci Technol 2003, 63:427-435.
-
(2003)
Compos Sci Technol
, vol.63
, pp. 427-435
-
-
Veerabagu, S.1
Fujihara, K.2
Dasari, G.R.3
Ramakrishna, S.4
-
4
-
-
77950866822
-
-
Design of a flexible composite bone plate for bone fracture healing. In: Proceedings of the 14th international conference on composite structures. Melbourne, Australia;
-
Kim JH, Chang SH. Design of a flexible composite bone plate for bone fracture healing. In: Proceedings of the 14th international conference on composite structures. Melbourne, Australia; 2007.
-
(2007)
-
-
Kim, J.H.1
Chang, S.H.2
-
5
-
-
0036854433
-
Evolution of the internal fixation of long bone fractures
-
Perren S.M. Evolution of the internal fixation of long bone fractures. J Bone Joint Surg 2002, 84-B:1093-1110.
-
(2002)
J Bone Joint Surg
, pp. 1093-1110
-
-
Perren, S.M.1
-
6
-
-
0033968708
-
The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture - an FEM study
-
Gardner T.N., Stoll T. The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture - an FEM study. J Biomech 2000, 33:415-425.
-
(2000)
J Biomech
, vol.33
, pp. 415-425
-
-
Gardner, T.N.1
Stoll, T.2
-
7
-
-
0019773457
-
Time evolution of the mechanical properties of the callus of fresh fractures
-
Christel P., Cerf G., Pilla A. Time evolution of the mechanical properties of the callus of fresh fractures. Ann Biomed Eng 1981, 9:383-391.
-
(1981)
Ann Biomed Eng
, vol.9
, pp. 383-391
-
-
Christel, P.1
Cerf, G.2
Pilla, A.3
-
8
-
-
0020585520
-
How stiff should semi-rigid fixation of the human tibia be?
-
Tayton K., Bradley J. How stiff should semi-rigid fixation of the human tibia be?. J Bone Joint Surg 1983, 65-B:312-315.
-
(1983)
J Bone Joint Surg
, pp. 312-315
-
-
Tayton, K.1
Bradley, J.2
-
9
-
-
2342435887
-
Damping analysis of unidirectional glass and Kevlar fibre composites
-
Berthelot J.M., Sefrani Y. Damping analysis of unidirectional glass and Kevlar fibre composites. Compos Sci Technol 2004, 64:1261-1278.
-
(2004)
Compos Sci Technol
, vol.64
, pp. 1261-1278
-
-
Berthelot, J.M.1
Sefrani, Y.2
-
10
-
-
77950866142
-
-
An advanced structural design for bone plate. In: Proceeding of 18th international society of biomechanics congress. Zurich, Switzerland;
-
Yildiz H, Erden S. An advanced structural design for bone plate. In: Proceeding of 18th international society of biomechanics congress. Zurich, Switzerland; 2001.
-
(2001)
-
-
Yildiz, H.1
Erden, S.2
-
11
-
-
0034308380
-
Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur
-
Wirtz D.C., Schiffers N. Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. J Biomech 2000, 33:1325-1330.
-
(2000)
J Biomech
, vol.33
, pp. 1325-1330
-
-
Wirtz, D.C.1
Schiffers, N.2
-
12
-
-
34249945682
-
Static optimization of muscle forces during gait in comparison to EMG-to-force processing approach
-
Heintz S., Gutierrez-Farewik E.M. Static optimization of muscle forces during gait in comparison to EMG-to-force processing approach. Gait Posture 2007, 26:279-288.
-
(2007)
Gait Posture
, vol.26
, pp. 279-288
-
-
Heintz, S.1
Gutierrez-Farewik, E.M.2
-
13
-
-
0035142680
-
Static and dynamic optimization solutions for gait are practically equivalent
-
Anderson F.C., Pandy M.G. Static and dynamic optimization solutions for gait are practically equivalent. J Biomech 2001, 34:153-161.
-
(2001)
J Biomech
, vol.34
, pp. 153-161
-
-
Anderson, F.C.1
Pandy, M.G.2
|