메뉴 건너뛰기




Volumn 43, Issue 6, 2010, Pages 1125-1130

What humeri are suitable for comparative testing of suture anchors? An ultrastructural bone analysis and biomechanical study of ovine, bovine and human humeri and four different anchor types

Author keywords

Anchor; Animal; Bone quality; Human; Stability

Indexed keywords

BIOMECHANICAL STUDIES; COMPARATIVE TESTING; CORTICAL LAYERS; CORTICAL THICKNESS; CYCLIC LOADINGS; FIXATION DEVICE; HUMAN; HUMAN BONES; PULL-OUT FORCE; ROTATOR CUFF; STATISTICAL SIGNIFICANCE; SUTURE ANCHOR; TRABECULAR BONES; ULTIMATE FAILURE;

EID: 77950691711     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.12.021     Document Type: Article
Times cited : (14)

References (22)
  • 2
    • 0028954390 scopus 로고
    • The deadman theory of suture anchors: observations along a south Texas fence line
    • Burkhart S.S. The deadman theory of suture anchors: observations along a south Texas fence line. Arthroscopy 1995, 11:119-123.
    • (1995) Arthroscopy , vol.11 , pp. 119-123
    • Burkhart, S.S.1
  • 3
    • 0031452936 scopus 로고    scopus 로고
    • Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation
    • Burkhart S.S., Diaz Pagan J.L., Wirth M.A., Athanasiou K.A. Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 1997, 13:720-724.
    • (1997) Arthroscopy , vol.13 , pp. 720-724
    • Burkhart, S.S.1    Diaz Pagan, J.L.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 4
    • 21444435692 scopus 로고    scopus 로고
    • Failure mode of suture anchors as a function of insertion depth
    • Bynum C.K., Lee S., Mahar A., Tasto J., Pedowitz R. Failure mode of suture anchors as a function of insertion depth. Am. J. Sports Med. 2005, 33:1030-1034.
    • (2005) Am. J. Sports Med. , vol.33 , pp. 1030-1034
    • Bynum, C.K.1    Lee, S.2    Mahar, A.3    Tasto, J.4    Pedowitz, R.5
  • 5
    • 51249105749 scopus 로고    scopus 로고
    • Regional variations of vertebral trabecular bone microstructure with age and gender
    • Chen H., Shoumura S., Emura S., Bunai Y. Regional variations of vertebral trabecular bone microstructure with age and gender. Osteoporos. Int. 2008, 19:1473-1483.
    • (2008) Osteoporos. Int. , vol.19 , pp. 1473-1483
    • Chen, H.1    Shoumura, S.2    Emura, S.3    Bunai, Y.4
  • 6
    • 33750458999 scopus 로고    scopus 로고
    • Triple-loaded single-anchor stitch configurations: an analysis of cyclically loaded suture-tendon interface security
    • Coons D.A., Barber F.A., Herbert M.A. Triple-loaded single-anchor stitch configurations: an analysis of cyclically loaded suture-tendon interface security. Arthroscopy 2006, 22:1154-1158.
    • (2006) Arthroscopy , vol.22 , pp. 1154-1158
    • Coons, D.A.1    Barber, F.A.2    Herbert, M.A.3
  • 7
    • 26844477493 scopus 로고    scopus 로고
    • Rotator cuff repair: an ex vivo analysis of suture anchor repair techniques on initial load to failure
    • Cummins C.A., Appleyard R.C., Strickland S., Haen P.S., Chen S., Murrell G.A. Rotator cuff repair: an ex vivo analysis of suture anchor repair techniques on initial load to failure. Arthroscopy 2005, 21:1236-1241.
    • (2005) Arthroscopy , vol.21 , pp. 1236-1241
    • Cummins, C.A.1    Appleyard, R.C.2    Strickland, S.3    Haen, P.S.4    Chen, S.5    Murrell, G.A.6
  • 9
    • 0033956461 scopus 로고    scopus 로고
    • Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous bone
    • Ding M., Hvid I. Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous bone. Bone 2000, 26:291-295.
    • (2000) Bone , vol.26 , pp. 291-295
    • Ding, M.1    Hvid, I.2
  • 10
    • 0032911349 scopus 로고    scopus 로고
    • Determination of the role of the cancellous bone in generation of screw holding power at metaphysis
    • Harnroongroj T., Techataweewan A. Determination of the role of the cancellous bone in generation of screw holding power at metaphysis. Clin. Biomech. (Bristol, Avon) 1999, 14:364-366.
    • (1999) Clin. Biomech. (Bristol, Avon) , vol.14 , pp. 364-366
    • Harnroongroj, T.1    Techataweewan, A.2
  • 11
    • 0033047422 scopus 로고    scopus 로고
    • Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus
    • Hildebrand T., Laib A., Muller R., Dequeker J., Ruegsegger P. Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J. Bone Miner. Res. 1999, 14:1167-1174.
    • (1999) J. Bone Miner. Res. , vol.14 , pp. 1167-1174
    • Hildebrand, T.1    Laib, A.2    Muller, R.3    Dequeker, J.4    Ruegsegger, P.5
  • 12
    • 33845667858 scopus 로고    scopus 로고
    • Biomechanical comparison of double-loaded suture anchors using arthroscopic Mason-Allen stitches versus traditional transosseous suture technique and modified Mason-Allen stitches for rotator cuff repair
    • Klinger H.M., Steckel H., Spahn G., Buchhorn G.H., Baums M.H. Biomechanical comparison of double-loaded suture anchors using arthroscopic Mason-Allen stitches versus traditional transosseous suture technique and modified Mason-Allen stitches for rotator cuff repair. Clin. Biomech. (Bristol, Avon) 2007, 22:106-111.
    • (2007) Clin. Biomech. (Bristol, Avon) , vol.22 , pp. 106-111
    • Klinger, H.M.1    Steckel, H.2    Spahn, G.3    Buchhorn, G.H.4    Baums, M.H.5
  • 13
    • 33750940583 scopus 로고    scopus 로고
    • Biomechanical comparison of traditional and locked suture configurations for arthroscopic repairs of the rotator cuff
    • Koganti A.K., Adamson G.J., Gregersen C.J., Pink M.M., Shankwiler J.A. Biomechanical comparison of traditional and locked suture configurations for arthroscopic repairs of the rotator cuff. Am. J. Sports Med. 2006, 34:1832-1838.
    • (2006) Am. J. Sports Med. , vol.34 , pp. 1832-1838
    • Koganti, A.K.1    Adamson, G.J.2    Gregersen, C.J.3    Pink, M.M.4    Shankwiler, J.A.5
  • 14
    • 11844275373 scopus 로고    scopus 로고
    • Biomechanical comparison of bioabsorbable sutureless screw anchor versus suture anchor fixation for rotator cuff repair
    • Lee S., Mahar A., Bynum K., Pedowitz R. Biomechanical comparison of bioabsorbable sutureless screw anchor versus suture anchor fixation for rotator cuff repair. Arthroscopy 2005, 21:43-47.
    • (2005) Arthroscopy , vol.21 , pp. 43-47
    • Lee, S.1    Mahar, A.2    Bynum, K.3    Pedowitz, R.4
  • 15
    • 33750442166 scopus 로고    scopus 로고
    • The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study
    • Meier S.W., Meier J.D. The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study. Arthroscopy 2006, 22:1168-1173.
    • (2006) Arthroscopy , vol.22 , pp. 1168-1173
    • Meier, S.W.1    Meier, J.D.2
  • 16
    • 1942532792 scopus 로고    scopus 로고
    • Association of osteopenia of the humeral head with full-thickness rotator cuff tears
    • Meyer D.C., Fucentese S.F., Koller B., Gerber C. Association of osteopenia of the humeral head with full-thickness rotator cuff tears. J. Shoulder Elbow Surg. 2004, 13:333-337.
    • (2004) J. Shoulder Elbow Surg. , vol.13 , pp. 333-337
    • Meyer, D.C.1    Fucentese, S.F.2    Koller, B.3    Gerber, C.4
  • 20
    • 0036951311 scopus 로고    scopus 로고
    • Primary strength of conventional and alternative suture techniques of the rotator cuff. A biomechanical study
    • Rickert M., Witzel U., Kolbel R., Georgousis H. Primary strength of conventional and alternative suture techniques of the rotator cuff. A biomechanical study. Unfallchirurg 2002, 105:23-30.
    • (2002) Unfallchirurg , vol.105 , pp. 23-30
    • Rickert, M.1    Witzel, U.2    Kolbel, R.3    Georgousis, H.4
  • 22
    • 26944498694 scopus 로고    scopus 로고
    • Mechanical behavior of screws in normal and osteoporotic bone
    • Seebeck J., Goldhahn J., Morlock M.M., Schneider E. Mechanical behavior of screws in normal and osteoporotic bone. Osteoporos. Int. 2005, 16(Suppl 2):S107-S111.
    • (2005) Osteoporos. Int. , vol.16 , Issue.SUPPL. 2
    • Seebeck, J.1    Goldhahn, J.2    Morlock, M.M.3    Schneider, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.