메뉴 건너뛰기




Volumn 16, Issue SUPPL. 2, 2005, Pages

Mechanical behavior of screws in normal and osteoporotic bone

Author keywords

Bone morphology; Osteoporosis; Screw anchorage

Indexed keywords

ADULT; AGED; BONE DENSITOMETRY; BONE DENSITY; BONE SCREW; CANCELLOUS BONE; CONFERENCE PAPER; CONTROLLED STUDY; CORRELATION ANALYSIS; CORTICAL BONE; DIAPHYSIS; EPIPHYSIS; FEMALE; HUMAN; HUMAN TISSUE; MALE; METAPHYSIS; MORPHOLOGY; MULTIPLE LINEAR REGRESSION ANALYSIS; OSTEOPOROSIS; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; TIBIA; ARTICLE; BIOMECHANICS; COMPUTER ASSISTED TOMOGRAPHY; EQUIPMENT DESIGN; FRACTURE FIXATION; HISTOLOGY; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; PATHOLOGY; PATHOPHYSIOLOGY; PHYSIOLOGY;

EID: 26944498694     PISSN: 0937941X     EISSN: 14332965     Source Type: Journal    
DOI: 10.1007/s00198-004-1777-0     Document Type: Conference Paper
Times cited : (99)

References (15)
  • 2
    • 0018894951 scopus 로고
    • A comparative estimation of the combined cortical thickness of various bone sites
    • Bloom RA (1980) A comparative estimation of the combined cortical thickness of various bone sites. Skeletal Radiol 5:167-170
    • (1980) Skeletal Radiol , vol.5 , pp. 167-170
    • Bloom, R.A.1
  • 3
    • 0034025662 scopus 로고    scopus 로고
    • Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws
    • Brown GA, McCarthy T, Bourgeault CA, Callahan DJ (2000) Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws. J Orthop Res 18:307-312
    • (2000) J Orthop Res , vol.18 , pp. 307-312
    • Brown, G.A.1    McCarthy, T.2    Bourgeault, C.A.3    Callahan, D.J.4
  • 6
    • 0036133362 scopus 로고    scopus 로고
    • Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry
    • Eckstein F, Lochmuller EM, Lill CA, Kuhn V, Schneider E, Delling G, Muller R (2002) Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry. J Bone Miner Res 17:162-171
    • (2002) J Bone Miner Res , vol.17 , pp. 162-171
    • Eckstein, F.1    Lochmuller, E.M.2    Lill, C.A.3    Kuhn, V.4    Schneider, E.5    Delling, G.6    Muller, R.7
  • 8
    • 10644243673 scopus 로고    scopus 로고
    • Frigg R (2001) Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and the Point Contact Fixator (PC-Fix). Injury 32 (Suppl) 2:63-66
    • Frigg R (2001) Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and the Point Contact Fixator (PC-Fix). Injury 32 (Suppl) 2:63-66
  • 9
    • 0032911349 scopus 로고    scopus 로고
    • Determination of the role of the cancellous bone in generation of screw holding power at metaphysis
    • Harnroongroj T, Techataweewan A (1999) Determination of the role of the cancellous bone in generation of screw holding power at metaphysis. Clin Biomech 14:364-366
    • (1999) Clin Biomech , vol.14 , pp. 364-366
    • Harnroongroj, T.1    Techataweewan, A.2
  • 10
    • 0032951118 scopus 로고    scopus 로고
    • Conventional radiology of osteoporosis and radiographic absorptiometry
    • Jergas M, Schmid G (1999) Conventional radiology of osteoporosis and radiographic absorptiometry. Radiologe 39:174-185
    • (1999) Radiologe , vol.39 , pp. 174-185
    • Jergas, M.1    Schmid, G.2
  • 11
    • 0035705777 scopus 로고    scopus 로고
    • Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database
    • Messmer P, Long G, Suhm N, Regazzoni P, Jacob AL (2001) Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database. Comput Aided Surg 6:183-194
    • (2001) Comput Aided Surg , vol.6 , pp. 183-194
    • Messmer, P.1    Long, G.2    Suhm, N.3    Regazzoni, P.4    Jacob, A.L.5
  • 13
    • 0032998150 scopus 로고    scopus 로고
    • Accuracy limits for the determination of cortical width and density: The influence of object size and CT imaging parameters
    • Prevrhal S, Engelke K, Kalender WA (1999) Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. Phys Med Biol 44:751-764
    • (1999) Phys Med Biol , vol.44 , pp. 751-764
    • Prevrhal, S.1    Engelke, K.2    Kalender, W.A.3
  • 14
    • 0026154992 scopus 로고
    • Estimation of mechanical properties of cortical bone by computed tomography
    • Snyder SM, Schneider E (1991) Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9:422-431
    • (1991) J Orthop Res , vol.9 , pp. 422-431
    • Snyder, S.M.1    Schneider, E.2
  • 15
    • 0027714980 scopus 로고
    • Holding power of the 4.5 mm AO/ASIF cortex screw in cortical bone in relation to bone mineral
    • Stromsoe K, Kok WL, Hoiseth A, Alho A (1993) Holding power of the 4.5 mm AO/ASIF cortex screw in cortical bone in relation to bone mineral. Injury 24:656-659
    • (1993) Injury , vol.24 , pp. 656-659
    • Stromsoe, K.1    Kok, W.L.2    Hoiseth, A.3    Alho, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.