메뉴 건너뛰기




Volumn , Issue , 2009, Pages 192-195

A ±9 V fully integrated CMOS electrode driver for high-impedance microstimulation

Author keywords

[No Author keywords available]

Indexed keywords

CHARGE PUMP; CMOS ELECTRODES; CONSTANT CURRENT; FULLY INTEGRATED; HIGH VOLTAGE ELECTRODES; HIGH-VOLTAGES; IN-VIVO; LATCH-UPS; LOW RIPPLE; MICROSTIMULATION; NEGATIVE CHARGE; OUTPUT VOLTAGES; TISSUE CONTACT; VOLTAGE SWINGS;

EID: 77950666593     PISSN: 15483746     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MWSCAS.2009.5236121     Document Type: Conference Paper
Times cited : (16)

References (10)
  • 1
    • 39849104171 scopus 로고    scopus 로고
    • A highly flexible system for microstimulation of the visual cortex: Design and implementation
    • DOI 10.1109/TBCAS.2007.916026
    • J. Coulombe, M. Sawan, and J. F. Gervais, "A Highly Flexible System for Microstimulation of the Visual Cortex: Design and Implementation," IEEE Trans. Biom. Circuits & Systems, Vol. 1, No. 4, pp. 258-269, 2007. (Pubitemid 351314691)
    • (2007) IEEE Transactions on Biomedical Circuits and Systems , vol.1 , Issue.4 , pp. 258-269
    • Coulombe, J.1    Sawan, M.2    Gervais, J.-F.3
  • 3
    • 48449088731 scopus 로고    scopus 로고
    • Cochlear implants: A remarkable past and a brilliant future
    • B. Wilson and M. Dorman, "Cochlear implants: A remarkable past and a brilliant future," Hearing Research, Vol. 242, No. 1-2, pp. 3-21, 2008.
    • (2008) Hearing Research , vol.242 , Issue.1-2 , pp. 3-21
    • Wilson, B.1    Dorman, M.2
  • 4
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • DOI 10.1016/j.jneumeth.2004.10.020, PII S0165027004003826
    • D. R. Merrill, M. Bikson, and J. G. R. Jefferys, "Electrical stimulation of excitable tissue: design of efficacious and safe protocols," J. Neurosci. Methods, Vol. 141, No. 2, pp. 171-198, 2005. (Pubitemid 40136531)
    • (2005) Journal of Neuroscience Methods , vol.141 , Issue.2 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.G.R.3
  • 6
    • 34548008149 scopus 로고    scopus 로고
    • A microassembled low-profile three-dimensional microelectrode array for neural prosthesis applications
    • DOI 10.1109/JMEMS.2007.896712
    • Y. Yao et al., "A Microassembled Low-Profile Three-Dimensional Microelectrode Array for Neural Prosthesis Applications," J. Microelectromech. Syst., Vol. 16, No. 4, pp. 977-988, 2007. (Pubitemid 47278839)
    • (2007) Journal of Microelectromechanical Systems , vol.16 , Issue.4 , pp. 977-988
    • Yao, Y.1    Gulari, M.N.2    Wiler, J.A.3    Wise, K.D.4
  • 7
    • 0141885997 scopus 로고    scopus 로고
    • An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias DAC
    • S. DeMarco et al., "An Arbitrary Waveform Stimulus Circuit for Visual Prostheses Using a Low-Area Multibias DAC," IEEE J. Solid-State Circuits, Vol. 38, No. 10, pp. 1679 - 1690, 2003.
    • (2003) IEEE J. Solid-state Circuits , vol.38 , Issue.10 , pp. 1679-1690
    • DeMarco, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.